HomeMy WebLinkAboutRFP - P878 GEOTECHNICAL TESTING SERVICE ANNUALREQUEST FOR PROPOSALS
GEOTECHNICAL TESTING SERVICE
P-878
DUE DATE: 3:00 P.M. (OUR CLOCK) January 28, 2003
2
REQUEST FOR PROPOSALS
GEOTECHNICAL TESTING SERVICES
For
THE CITY OF FORT COLLINS
ENGINEERING DEPARTMENT
Proposal No. P-878
The City of Fort Collins Engineering Department is seeking a qualified consultant firm to perform
construction material testing for street projects and other similar projects on an as-needed basis.
Written proposals, four (4) will be received at the City of Fort Collins' Purchasing Division, 215
North Mason St., 2nd floor, Fort Collins, Colorado 80524. Proposals will be received before
3:00 p.m. (our clock), January 28, 2003. Proposal No. P-878. If delivered, they are to be sent to
215 North Mason Street, 2nd Floor, Fort Collins, Colorado 80521. If mailed, the address is P.O.
Box 580, Fort Collins, 80522-0580.
A Pre-Proposal conference will be held at 215 N Mason, 2nd floor, conference room 2A on,
January 9, 2003 at 10:00 am. We strongly recommend attendance at this pre-proposal meeting
if your firm intends to submit a proposal.
Your proposal should include the completed bid schedule and a list of other testing services you
perform with prices for those services; the time frame required to perform such services;
qualifications; and a list of projects similar in nature with references for those projects. We are
very concerned with turn around time on testing and response time to requests for testing.
Please address these issues in your proposal. Please keep your proposals brief and concise.
Questions concerning the scope of this project should be directed to Rick Richter, Project
Manager, at (970) 221-6798.
Questions regarding proposal submittal or process should be directed to John Stephen, Senior
Buyer, at (970) 221-6775.
A copy of the Proposal may be obtained as follows:
1. Call the Purchasing Fax-line, 970-416-2033 and follow the verbal instruction to
request document #30878.
2. Download the Proposal/Bid from the Purchasing Webpage,
www.fcgov.com/purchasing.
3. Come by Purchasing at 215 North Mason St., 2nd floor, Fort Collins, and request
a copy of the Bid.
Sales Prohibited / Conflict of Interest: No officer, employee, or their dependent or person
residing in and sharing the expenses of their household, shall have a financial interest in the
sale to the City of any real or personal property, equipment, material, supplies, or services. This
rule also applies to subcontracts with the City. This shall not apply to members of any authority,
board, committee or commission of the City, other than the members of the City Council.
Soliciting or accepting any gift, gratuity, favor, entertainment, kick-back or any items of monetary
value from any person who has sought or is seeking to do business with the City of Fort Collins
is prohibited. Any vendor knowing of this type of activity is encouraged to report in confidence
to the Director of Purchasing and Risk Management, the Director of Finance, the City Attorney,
or the City Manager so the matter can be dealt with.
3
Collusive or Sham Proposals: Any proposal deemed to be collusive or a sham proposal will
be rejected and reported to the relevant authorities as such. Your authorized signature on your
proposal submittal assures that such proposal is genuine and is not a collusive or sham
proposal.
The City of Fort Collins reserves the right to reject any and all proposals and to waive any
irregularities or informalities.
Sincerely,
James B. O'Neill II, CPPO, FNIGP
Director of Purchasing & Risk Management
4
1. SELECTION CRITERIA AND METHOD
The City's Capital Project Management Control System Manual prescribes the consultant
selection criteria and method. A copy of the review and assessment criteria is attached.
2. TERMS AND CONDITIONS
The payment for services as described under the Scope of Services shall be based on unit
prices and reimbursement rates for completed services. The Consultant shall include in their
proposal a detailed list of unit costs and reimbursement rates for the services requested.
The Professional Services Agreement shall commence approximately February 2003 and
continue in full force and effect for one year. At the option of the City, the Professional Services
Agreement may be extended for up to four (4) additional one-year terms. Increases in the Fee
Schedule may be negotiated for subsequent renewal of the third, fourth, and fifth additional one-
year periods. Price changes in the Fee Schedule will be negotiated by and agreed to by both
parties and any increases shall not exceed the Denver-Boulder CPI index.
The Contract may and will be used at the option of other City Departments.
Use of Subcontractors
The Consultant shall indicate in their proposal any work intended to be performed by
subcontractors or persons outside of the firm. The Consultant shall name the
subcontractors, if known at the time the proposal is submitted. If the names of
subcontractors are not presented in the proposal, the City reserves the right of approval
or rejection.
3. SCOPE OF SERVICES
Engineering has the following street projects which may require geotechnical services over the
next two years: North College Improvement Project, Prospect Road from Prospect Parkway to
Summit View Drive, Pedestrian Access Program, and Minor Bridge Maintenance Program. In
addition the Engineering Construction Inspectors may need geotechnical services and or
inspection services to help them resolve problems with private developments. Engineering also
manages the annual street maintenance program. The 2003 and 2004 programs will involve
over 7 million dollars of street work each year. The following is a brief description of the services
estimated we will need in the Engineering Department.
The City spent approximately $100,000 in 2002 for services. The 2002 Street Maintenance
project, included a total of over 80,000 tons of asphalt placed, and over 25,000 lineal feet of
concrete curb gutter, and walk constructed. We expect similar quantities in the 2003 project. The
testing frequency will be as specified in the “Larimer County Urban Area Street Standards”.
Some of the tests required for the Street Maintenance Project are asphalt extraction and
gradation, sampling aggregate at the asphalt plant and running a gradation, and physical
property and strength tests on concrete.
There will be construction projects on: North College from Jefferson Street to Cherry Street and
Jefferson/Riverside Avenue between Mulberry Avenue and College Avenue; Prospect Road
from Prospect Parkway to Summit View Drive; Lemay Avenue from Fossil Creek Boulevard to
Trilby Road; and the Taft Hill Bridge just south of Laporte Avenue. Some of the tests required for
these projects are asphalt extraction and gradation, sampling aggregate at the asphalt plant and
5
burrow sources and running a gradation, and physical property and strength tests on concrete
and soils tests such as proctors and nuclear field density tests. The testing frequency will also
be comparable to that of the Larimer County Urban Area Street Standards.
There will also be several miscellaneous projects including the Pedestrian Access Program,
Parks and Utility Projects. These projects will require a variety of tests.
The purpose of the nuclear asphalt content test is to provide us with a rapid turnaround of
asphalt contents throughout the construction season. We would expect a gauge to be available
throughout the construction season. We anticipate the need for approximately 100 nuclear
asphalt content tests during the 2003 construction season. Due to the anticipated change in oil
and aggregate throughout the project, a price for a mix calibration for the asphalt content gauge
is included in this contract
If the Geotechnical Consultant can assure the City of fast turn around on the asphalt extraction
tests, the nuclear asphalt content test may not be needed as part of the contract.
The above mentioned tests will be required on short notice (four to six hours) for Concrete and
Asphalt tests and (Two to four hours) for soils tests and often response time may be within one
to two hours. A field copy of the physical property concrete tests will need to be left on site with
the City representative at the time of the test. A prompt verbal (phone) notice on all
noncompliance tests will be required immediately after tests are completed. All tests will be
followed up with a hard copy of test results including a comparison to the specifications for that
particular project, indicating any test results that are out of specification. As directed by the
Project Manager and on continues projects out of specification tests shall be tracked until a
passing test is achieved and documented as an actable retest. The hard copies shall be
submitted within 48 hours. We expect all costs such as mileage, labor, equipment, typing,
reviewing, and report writing to be included in all prices submitted.
The normal construction hours for the City of Fort Collins are from 7:00 am. to 6:00 pm. Monday
thru Saturday. The cost of performing tests during the normal work hours should be included in
the unit price for each test. If there will be an overtime charge for work outside of these hours
that charge must be addressed in your proposal. The City will give the consultant 24 hours
notice for weekend testing.
The following is a list of time allowed for some of the more frequently used testing services.
Please address in your proposal how and when standby time is charged by your firm.
Time allowed for field test without standby time being charged:
Concrete Physical Property Tests 1 Hour per test
Nuclear Asphalt Densities 15 Minutes per test
Nuclear Soils Densities 15 Minutes per test
Asphalt Content Sample 30 Minutes per test
All field technicians shall meet the Larimer County Urban Area Street Standards for certification.
All personnel shall be qualified to perform the assigned tasks or they shall be replaced with
qualified personnel at the request of the City.
6
4. BID SCHEDULE
ITEM NO. DESCRIPTION Unit PRICE
SOILS
101 Atterberg Limits; Classification Liquid Limit,
Plastic Limit, Plasticity Index Ea. Test $ ___________
102 Hveem Stabilometer - "R" Value Ea. $ ___________
103 Proctor - Standard Ea. $ ___________
104 Proctor - Modified Ea. $ ___________
105 Proctor - One Point Check Ea. $ ___________
106 PH Determination Ea. $ ___________
107 Nuclear Field Density Test 3 or
More Tests Per Trip Ea.
Test $ ___________
108 Nuclear Field Density Test, Less
Then 3 Tests Per Trip Ea. Test $ ___________
109 Sieve Analysis - (Plus #4 Material) Ea. Test $ ___________
110 Sieve Analysis - (Plus #4 Material) Ea. Test $ ___________
111 Sieve Analysis - (#4 to minus 200 Material) Ea. Test $ ___________
112 Organic Content for Top Soil Ea. Test $ ___________
113 Hydrometer Analysis Ea. Test $ ___________
CONCRETE
201 Concrete Cylinders (Including sampling in Field, Slump, Unit
Weight, Yield, Air Content, Temperature, Casting, Curing
Testing and Reporting) Set of 4 $ ___________
202 Additional Cylinder Per Cylinder $ ___________
203 Compression Test (Cap, Cure
and Break FOB Lab) Ea. Test $ ___________
204 Concrete Beams (Including
Sampling) Set of
3 $ ___________
205 Additional Beam Per Beam $ ___________
206 Sand Equivalent (CP-30) Ea. Test $ ___________
ASPHALT
301 Sieve Analysis - (Plus #4 Material) Ea. Test $ ___________
302 Sieve Analysis - (Minus #4 Material) Ea. Test $ ___________
303 Specific Gravity and Absorption
(Plus #4 Material) Ea. Test $ ___________
304 Specific Gravity and Absorption
(Minus #4 Material) Ea. Test $ ___________
7
305 L.A. Abrasion Test Ea. Test $ ___________
306 Fractured Face Determination Ea. Test $ ___________
307 Flat and Elongated Particles Ea. Test $ ___________
308 Maximum Theoretical Specific Gravity
for Air Voids (Rice) Ea. Test $ ___________
309 Lottman (TSR) Test Ea. Test $ ___________
310 Mix Design Bulk Unit Weight and
Hveem Stability Verification Ea. Test $ ___________
311 Sand Equivalent Ea. Test $ ___________
312 Determination of Bitumen Content by Extraction, Gradation Analysis
of Extracted Aggregate (To be
sampled by Consultant) Ea. Sample $ ___________
313 Dtermination of Bitumen Content by Extraction
(To be Sampled by Consultant) Ea. Sample $ ___________
314 Determination of Bitumen Content
by Nuclear Gauge (To be Sampled
by Consultant) Ea. Sample $ ___________
315 Calibrate Nuclear Gauge(For a
New Asphalt Mix) Ea. Calibration$ ___________
316 Nuclear Field Density Tests (3 or
More Tests per Trip) Ea. Test $ ___________
317 Nuclear Field Density Tests (Less
Then 3 Tests per Trip) Ea. Test $ ___________
318 Asphalt Plant Inspection Per Hour $ ___________
319 Core Field Samples Per Hour $
___________
Per Inch $ ___________
HOURLY RATES
401 Principal Engineer and/or Geologist
Per Hour
$____________
402 Geotechnical Engineer/ Department
Manager Per Hour
$____________
403 Senior Field Technician
Per Hour
$____________
404 Field Technician
Per Hour
$____________
NOTE: All prices shall include labor, mileage, testing, sampling, reviewing, typing and report writing as needed
for each service. The above listed items indicate the most frequently used tests. Please submit any other
testing services (include pricing) that your Company provides.
Signed ________________________________ Printed_________________________________
8
Company _______________________________
Address __________________________________________________________________________
Phone___________________Fax____________________E-mail_____________________________
Check One
__ Individual Doing Business in Company Name
__ Partnership
__ Corporation
WOPSA 05/01 2
5. REVIEW AND ASSESSMENT
Professional firms will be evaluated on the following criteria. These criteria will be the basis for
review of the written proposals. The rating scale shall be from 1 to 5, with 1 a poor rating, 3 an
average rating, and 5 an outstanding rating.
Weighting
Factor
Qualifications Standard
2.0 Scope of
Proposal
Does the proposal show an understanding of the project
objectives, methodology, and requirements?
Has the firm demonstrated innovative professional
approaches to problem-solving?
2.0 Assigned
Personnel
Do the persons who will work on the contract have the
necessary skills?
Are sufficient people of the requisite skills assigned to the
contract?
1.0 Availability Can the work be completed in the time frame required?
Can targeted start- and completion dates be met?
Can qualified staff be made available as needed?
Does the senior staff have adequate time available?
What is the ratio of senior staff to junior staff?
1.0 Motivation Is the firm interested in the work?
Are they committed to successful performance and
completion of the contract?
2.0 Costs Is the company cost-competitive and cost-effective?
Are they capable of controlling their costs and meeting on-
time performance?
2.0 Capability of the
Firm
Does the firm have the technical experience, quality
assurance and quality control procedures, and staff to
perform the contract?
Can the firm provide special expertise, additional staff, or
specialized subconsultants for this contract?
Has the firm previously performed the type and full range
of services required?
Reference evaluation (Top Ranked Firm)
The project Manager will check references using the following criteria. The evaluation rankings
will be labeled Satisfactory/Unsatisfactory.
WOPSA 05/01 3
QUALIFICATION STANDARD
Overall Performance Would you hire this
Professional again? Did they show the skills
required by this project?
Timetable Was the original
Scope of Work completed within the specified time?
Were interim deadlines met in a timely manner?
Completeness Was the Professional
responsive to client needs; did the Professional
anticipate problems? Were problems solved
quickly and effectively?
Budget Was the
original Scope of Work completed within the project
budget?
Job Knowledge a) If a study, did it meet the
Scope of work?
b) If Professional administered a construction
contract, was the project functional upon
completion and did it operate properly? Were
problems corrected quickly and effectively?
WOPSA 05/01 4
PROFESSIONAL SERVICES AGREEMENT
WORK ORDER TYPE
THIS AGREEMENT made and entered into the day and year set forth below by and
between THE CITY OF FORT COLLINS, COLORADO, a Municipal Corporation, hereinafter
referred to as the "City" and CTL/Thompson, Inc., hereinafter referred to as "Professional".
WITNESSETH:
In consideration of the mutual covenants and obligations herein expressed, it is agreed
by and between the parties hereto as follows:
1. Scope of Services. The Professional agrees to provide services in accordance
with any project Work Orders , issued by the City. A blank sample of a work order is attached
hereto as Exhibit "A", consisting of one (1) page and is incorporated herein by this reference.
No Work Order shall exceed $50,000. The City reserves the right to independently bid any
project rather than issuing a Work Order to the Professional for the same pursuant to this
Agreement.
2. The Work Schedule. The services to be performed pursuant to this Agreement
shall be performed in accordance with the Work Schedule stated on each Work Order.
3. Time of Commencement and Completion of Services. The services to be
performed pursuant to this Agreement shall be initiated as specified on each Work Order. Time
is of the essence. Any extensions of any time limit must be agreed upon in writing by the parties
hereto.
4. Contract Period. This Agreement shall commence upon signing of this
agreement , and shall continue in full force and effect until March 31, 2004, unless sooner
terminated as herein provided. In addition, at the option of the City, the Agreement may be
extended for additional one year periods not to exceed four (4) additional one year periods.
Pricing changes shall be negotiated by and agreed to by both parties and may not exceed the
WOPSA 05/01 5
Denver - Boulder CPI-U as published by the Colorado State Planning and Budget Office.
Written notice of renewal shall be provided to the Service Provider and mailed no later than
ninety (90) days prior to contract end.
5. Early Termination by City/Notice. Notwithstanding the time periods contained
herein, the City may terminate this Agreement at any time without cause by providing written
notice of termination to the Professional. Such notice shall be delivered at least fifteen (15)
days prior to the termination date contained in said notice unless otherwise agreed in writing by
the parties. All notices provided under this agreement shall be effective when mailed, postage
prepaid and sent to the following address:
Professional:
CTL/Thompson, Inc.
375 E. Horsetooth Rd.
Bldg. 3, Suite 100
Ft. Collins, CO 80525
City:
City of Fort Collins, Purchasing
P.O. Box 580
Ft. Collins, CO 80522
Attn: John Stephen
With copy to:
City of Fort Collins, Engineering
P.O. Box 580
Ft. Collins, CO 80522
Attn: Rick Richter
In the event of any such early termination by the City, the Professional shall be paid for services
rendered prior to the date of termination subject only to the satisfactory performance of the
Professional's obligations under this Agreement. Such payment shall be the Professional's sole
right and remedy for such termination.
6. Design, Project Insurance and Insurance Responsibility. The Professional shall
be responsible for the professional quality, technical accuracy, timely completion and the
coordination of all services rendered by the Professional, including but not limited to designs,
plans, reports, specifications, and drawings and shall, without additional compensation, promptly
remedy and correct any errors, omissions, or other deficiencies. The Professional shall
indemnify, save and hold harmless the City its officers and employees, in accordance with
Colorado law, from all damages whatsoever claimed by third parties against the City and for the
City's costs and reasonable attorneys fees arising directly or indirectly out of the Professional's
WOPSA 05/01 6
negligent performance of any of the services furnished under this Agreement. The Professional
shall maintain commercial general liability insurance in the amount of $1,000,000 combined
single limits.
7. Compensation. In consideration of services to be performed pursuant to this
Agreement, the City agrees to pay Professional on a time and reimbursable direct cost basis
designated in Exhibit "B", consisting of nine (9) pages, attached hereto and incorporated herein
by this reference. At the election of the City, each Work Order may contain a maximum fee,
which shall be negotiated by the parties hereto for each such Work Order. Monthly partial
payments based upon the Professional's billings and itemized statements are permissible. The
amounts of all such partial payments shall be based upon the Professional's City-verified
progress in completing the services to be performed pursuant to the Work Order and upon
approval of the Professional's direct reimbursable expenses. Final payment shall be made
following acceptance of the work by the City. Upon final payment, all designs, plans, reports,
specifications, drawings, and other services rendered by the Professional shall become the sole
property of the City.
8. City Representative. The City will designate, prior to commencement of work, its
project representative who shall make, within the scope of his or her authority, all necessary and
proper decisions with reference to the project. All requests for contract interpretations, change
orders, and other clarification or instruction shall be directed to the City Representative.
9. Monthly Report. Commencing thirty (30) days after Notice to Proceed is given on
any Work Order and every thirty days thereafter, Professional is required to provide the City
Representative with a written report of the status of the work with respect to the Work Order,
Work Schedule and other material information. Failure to provide any required monthly report
may, at the option of the City, suspend the processing of any partial payment request.
10. Independent Contractor. The services to be performed by Professional are those
WOPSA 05/01 7
of an independent contractor and not of an employee of the City of Fort Collins. The City shall
not be responsible for withholding any portion of Professional's compensation hereunder for the
payment of FICA, Workers' Compensation, other taxes or benefits or for any other purpose.
11. Personal Services. It is understood that the City enters into this Agreement
based on the special abilities of the Professional and that this Agreement shall be considered as
an agreement for personal services. Accordingly, the Professional shall neither assign any
responsibilities nor delegate any duties arising under this Agreement without the prior written
consent of the City.
12. Acceptance Not Waiver. The City's approval of drawings, designs, plans,
specifications, reports, and incidental work or materials furnished hereunder shall not in any way
relieve the Professional of responsibility for the quality or technical accuracy of the work. The
City's approval or acceptance of, or payment for, any of the services shall not be construed to
operate as a waiver of any rights or benefits provided to the City under this Agreement.
13. Default. Each and every term and condition hereof shall be deemed to be a
material element of this Agreement. In the event either party should fail or refuse to perform
according to the terms of this agreement, such party may be declared in default .
14. Remedies. In the event a party has been declared in default, such defaulting
party shall be allowed a period of ten (10) days within which to cure said default. In the event
the default remains uncorrected, the party declaring default may elect to (a) terminate the
Agreement and seek damages; (b) treat the Agreement as continuing and require specific
performance; or (c) avail himself of any other remedy at law or equity. If the non-defaulting party
commences legal or equitable actions against the defaulting party, the defaulting party shall be
liable to the non-defaulting party for the non-defaulting party's reasonable attorney fees and
costs incurred because of the default.
15. Binding Effect. This writing, together with the exhibits hereto, constitutes the
WOPSA 05/01 8
entire agreement between the parties and shall be binding upon said parties, their officers,
employees, agents and assigns and shall inure to the benefit of the respective survivors, heirs,
personal representatives, successors and assigns of said parties.
16. Law/Severability. The laws of the State of Colorado shall govern the
construction, interpretation, execution and enforcement of this Agreement. In the event any
provision of this Agreement shall be held invalid or unenforceable by any court of competent
jurisdiction, such holding shall not invalidate or render unenforceable any other provision of this
Agreement.
THE CITY OF FORT COLLINS, COLORADO
By: _________________________________
John F. Fischbach
City Manager
By: _________________________________
James B. O'Neill II, CPPO, FNIGP
Director of Purchasing & Risk Management
Date: ______________________________
CTL/Thompson, Inc.
By: _________________________________
Title: _______________________________
CORPORATE PRESIDENT OR VICE PRESIDENT
Date: _______________________________
ATTEST:
_________________________________ (Corporate Seal)
Corporate Secretary
WOPSA 05/01 9
WOPSA 05/01 1
EXHIBIT "A"
WORK ORDER FORM
PURSUANT TO AN AGREEMENT BETWEEN
THE CITY OF FORT COLLINS
AND
______________________
DATED: _____________
Work Order Number:
____________________________________________________________
Purchase Order Number:
__________________________________________________________
Project Title:
_________________________________________________________________
Commencement Date:
___________________________________________________________
Completion Date:
________________________________________________________________
Maximum Fee: (time and reimbursable direct
costs):_____________________________________
Project Description:
______________________________________________________________
____________________________________________________________________________
___
Scope of Services:
_______________________________________________________________
____________________________________________________________________________
___
Acceptance
_______________________________________
User
Professional agrees to perform the services
identified above and on the attached forms
in accordance with the terms and conditions
contained herein and in the Professional
Services Agreement between the parties. In
the event of a conflict between or ambiguity
in the terms of the Professional Services
Agreement and this work order (including
the attached forms) the Professional
Services Agreement shall control.
Professional
By:________________________________
WOPSA 05/01 2
Date:_______________________________
The attached forms consisting of ___ (_)
pages are hereby accepted and
incorporated herein, by this reference, and
Notice to Proceed is hereby given.
City of Fort Collins
By:________________________________
__
Date:_______________________________
_
By:
___________________________________
_
Director of Purchasing and Risk
Management
Date:
___________________________________