HomeMy WebLinkAboutRESPONSE - BID - 5843 FIRE SPRINKLER SYSTEM AT STATION 3BID PROPOSAL BID 95843 FIRE SPRINKLER SYSTEM AT FIRE STATION 03 BID OPENING: MARCH 23.2004 3.00o m (our clock) WE HEREBY ENTER OUR BID FOR THE CITY OF FORT COLLINS REQUIREMENTS FOR FIRE SPRINKLER SYSTEM AT FIRE STATION 93 PER THE BID INVITATION AND ANY REFERENCED SPECIFICATIONS: The City Of Fort Collins is requesting bids for a fire sprinkler system for Station #3 located at 2000 Mathews, Ft Collins, CO. per the attached specifications. Contractor must fumish all labor, materials , equipment and permits for a complete job. Any technical questions should be directed to Mel Carlson, Project Manager, at 970-416-2871. Any purchasing questions regarding this bid should be directed to John Stephen, CPPO, CPPB, Senior Buyer at (970) 221-6775. A pre -bid will be held at the site on March 10, 2004 at 10:00 am. BID SCHEDULE Provide a fire sprinkler system for Station #3 per attached specifications for a complete job: LUMP SUM $_A 1.'11 9 Oy / 04 Firm Name FILb - 2C' Signature Z:Z2 /� Q Printed Name Ne rtf"n0 Address q I Z wr A -Fe pj 3 (all) ,vS Telephone # 4 a 4 -18 I "7 Fax# 4Q3-"7j Specifications and Scope of Work: Or.4 �� 1. Point of connection is tap at city main — provide 0 Fire Line into building. 2. Design in accordance with NFPA 13, and local jurisdiction. 3. Design density to be Light Hazard Occupancy in attic and residential areas, Ordinary Hazard in Apparatus Bay. 4. Antifreeze System due to unheated attic areas. 5. Hanger materials and installation in accordance with NFPA. 6. Materials per minimum requirements of NFPA. 7. Permits. 8. Field Labor and Installation, Hanging per NFPA 13. 9. Backflow preventer (Reduced Pressure Type). Flow Fire Frotection, Inc. BID PROPOSAL & SCOPE LETTER 912 Smithfield Dr., Unit 3 — Fort Collins, CO Office (970) 494-1817 - Fax (970) 493-7157 page 1 of 2 Date: March 23, 2004 To: City of Ft. Collins Attention: Director of Purchasing Reference: Fire Station # 3 Specification Section - — Fire Sprinkler System Thank you for the opportunity to provide your company with pricing for the above referenced project. The price has been based on the below scope inclusions/exclusions. Antifreeze type NFPA 13 Fire sprinkler system for Fire station, r underground Into building from street, monitoring panel (dialer) In riser room Included 3 1. The system would be installed to the latest version of NFPA 13 and to meet all local codes pertaining to the mentioned standard 2. Material and installation based on minimum requiremerrts of NFPA 13 and specifications — Dynathrred and Dynaflow pipe, C.I. and grooved fittings, and semi recessed chrome sprinklers 3. Light Hazard Occupancy .10 gpm/sq.ft design basis for residential portion, Ordinary Gp. 2 for Apparatus Bay 4. Design and Shop Drawings S. Reduced Pressure Backf ow Preventer 6. Permits and plan check fees 7. Antifreeze system throughout 8. Expansion Tank 9. V Underground Into building (not Was specified), run on South side of building from street. 10. Silent Knight dialer monitoring flow and tamper switches 11. One year warranty for system 1. Alarms, Detection, Remote Annunciator 2. Monthly monitoring fees 3. Payment and Performance Bonds 2. Head Guards 3. Electrical control or power wiring —110 V. dedkabad dircuit required at dialer panel by others 4. 2 phone lines, at least 1 dedicated, at dialer location ( by others) S. Kitchen Hood System or extinguishers 6. IRI, Factory Mutual, or other HRP insurers requirements more stringent than NFPA standard(s) cited above 7. High piled, rack storage, flammable liquids storage or spraying occupancies 8. Off hours or night work 9. Restoration of landscaping, lawn sprinkler repair, resod or seeding, pavement markings 10. Removal of bedrock from excavation 11. Painting of pipe or accessories 12. Centerline of Tile sprinkler placement 13. Asbestos abatement, or working under asbeshos containment area Flaw Fire Frot.eetion, Inc."Your Fire Protection Cotitmcwr" page 2 of 2 QuagaudiffiL 1. Scope and pricing is based on the following minimum water supply: Static: 75 psi Residual : 70 psi at 1200 gpm flow 2. Hanger materials and installation per NFPA standards 3. Work scope to start at street connection. 4. Pricing assumes two mobilizations on project —1 rough In, 1 trim out and test. S. Underground Fire Water Supply to be flushed, hydrotested, and chlorinated per all applicable standards by others before connection by Flow Fire Protection 6. Flow Fire Protection anticipates this project to have a duration of approbmately 6 months. If unforeseen delays causes the project to extend to a later time period, Flow Fire reserves the right to submit for additional compensation for increased material and labor costs. Base Bid Price Dollars $ 44,719,00 Monitoring fees or contract are not part of this proposal: — ADD S 30.00/month for 3 year contract Thank you for the opportunity to quote this project to your firm. please dont hesitate to contact me. Sincerely, Ken S n Operations Manager Flow Fire Protection If you have any questions regarding this proposal