HomeMy WebLinkAboutRESPONSE - BID - 5865 FIBER OPTIC CABLE SINGLE MODE (6)Bid #5865
Addendum #2
BID SCHEDULE
100,000 Ft. of 48 strand fiber optic cable delivered to Fort Collins, Colorado.
$ O, y/,ti /Ft. X 100,000 Ft = $ , 5VV Vie Total
Mfr. Ale-e-5.V&0 Mfr. #
Delivery in weeks: WAS
This bid meets or exceeds the specifications? YES NO
FIRM NAME --✓tiFe1y 1 Z1%ONg1 Z' 61e 491V<S0,6i4W Ti✓G,
Are you a Corporation, Partnership, DBA, LLC, or PC
SIGNATURE p a/ w �
ADDRESS 05?7 Gew& Aw &., le Y/S
F, i Zee , NJ t2 70-e%
PHONE/FAX#'/.
,
RECEIPT OF THIS ADDENDUM MUST BE ACKNOWLEDGED BY A WRITTEN STATEMENT
ENCLOSED WITH THE BID/QUOTE STATING THAT THIS ADDENDUM HAS BEEN
RECEIVED.
0 HEESUNG SpeciFcation No.
Rev. 1
HSOF 9021-US13 Page: 8110
o Test method: IEC 794-1-F1
-. Temperature cycling schedule
*23°C => -40°C * 70°C * -40°C * 70°C * 23°C
Temperature Cycling
-. Soak time at each temperature : 8 hours
• Acceptance criteria
-. During each temp.: 5 0.2 dB/km
-.After testing : 5 0.1 dB/km
* Test method : IEC 794-1-E7
-. Test cable length : 2m
-. No. of twist cycles : 10 cycles
-.Twist angle: ±180`
Torsion test
-.Applied load: 50 N
• Acceptance criteria
-. Attenuation increment : 5 0.1 d3
-. No jacket cracking & fiber breakage
o Test method : IEC 794-1-E6
-. Mandrel diameter: 20D (Cable outer diameter)
-.Bending angle: ±90°
Repeated Bending test
-. No. of cycles : 10 cycles
• Acceptance criteria
-. Attenuation increment: 5 0.1 d3
-. No jacket cracking & fiber breakage
* Test method : IEC 794-1-F5
-. Length of specimen: 3 m
Water penetration
-• Height of pressure head : 1 m
-. Test time: 24 hours
• Acceptance criteria
-. No leakage through the open cable end
(10 HEESUNG Specification No. Rev. 1
HSOF 9021-US13 Page: 9110
6. Typical Cross Sectional Diagram
See Appendix
7. Marking & Packing
7.1 Cable Marking
The jacket shall be marked at intervals of one meter or two feet with
following information.
,O Length marking
O Name of Manufacturer
® Year of manufacture
® Cable type $ size
7.2 Cable Packing
7.2.1 The cables shall be supplied on drum in lengths as specified at the time of contract.
The length of the standard reel shall be 2000m.
7.2.2 Each length of the cable shall be wound on a separate wooden reel.
7.2.3 The cable ends shall be accessible for testing.
7.2.4 Both ends of the cable shall be sealed with a heat shrinkable tubes to prevent
the entry of moisture during shipping, Handling and storage.
7.2.5 The cable ends shall be securely fastened to the reel to prevent the cable
from becoming loose in transit or curing placing operations.
7.2.6 Circumference battens or Wood -fiber board shall be secured with steel band
to protect the cable during normal handling and storage.
HEESUNG SpeciFcation No. Rev. 1
HSOF 9021-US13 Page: 10/ 10
7.3 Cable Reel
7.3.1 Details given below shall be distinctly marked on a weather proof materials
on both outer sides of the reel flange ;
1) End User Name
2) Length of cable in meter
3)Cable type & fiber counts
4)Gross & Net weight in kilograms
5)Reel number
6)Name of the manufacturer
7)Year of manufacture
8)Arrow showing the direction the drum shall be rolled.
Alternatively, the above reel marking contents can be marked used in
aluminium label on both outer sides of the reel flange.
7.3.2 The cable shall be wound on the reel designed to prevent damages during shipment
and installation.
7.3.3 The arbor hole on each flange shall be lined with a metal plate
END OF SPECIFICATION
0 HEESUNG Specification No.
Rev. 1
HSOF 9021-US13 Page: 11/ 10
APPENDIX
CALBLE CONSTRUCTION
[All Dielectric 48 fibers]
Loose tube with Optical fibers
And Thicotropic jelly compound
Water Swellable Yarn
Core Wrapping Tape
Peripheral Strength Member
Ripcord
Outer sheath
No. of
Fiber
Thickness
Outer
Cable
No. of
No. of
of
Cable
Fiber
Loose Tube
per
Sheath
Diameter
eight
Loose
(nom.mm)
(nom.mm)
(approx. g/km)
Tube
48
4
12
1.5
12.0
110
City of Fort Collins
Administrative Services
Purchasing Division
CITY OF FORT COLLINS
ADDENDUM No.1
BID #5865
FIBER OPTIC CABLE, SINGLE MODE
SPECIFICATIONS AND CONTRACT DOCUMENTS
Description of Bid #5865 FIBER OPTIC CABLE, SINGLE MODE
OPENING DATE: June 24, 2004, 3:00p.m. (Our Clock)
To all prospective bidders under the specifications and contract documents described above, the
following changes are hereby made.
The attached Federal Forms should be included in the Invitation to Bid.
If you have any questions please contact John Stephen, CPPO, Senior Buyer, at 970-221-6777.
RECEIPT OF THIS ADDENDUM MUST BE ACKNOWLEDGED BY A WRITTEN STATEMENT
ENCLOSED WITH THE BID/QUOTE STATING THAT THIS ADDENDUM HAS BEEN RECEIVED.
0
215 North Mason Street - 2nd Floor 9 P.O. Box 580 - Fort Collins, CO 80522-0580 - (970) 221-6775 - FAX (970) 221-6707
ISO 9001
ISSUED:. 7. Jun. 2004
REVISED : 21. Jun. 2004
PAGE: 1 of 10
Specification
HSOF 9021-US13
FOR
LOOSE TUBE TYPE OPTIC FIBER CABLE
Fiber — Single mode
S. H. LEE
Design Manager
H. J. KWON
Manager
Y. J. YOON
General Manager
Rev.1
Prepared
Checked
Approved
I0 HEESUNG CABLE LTD.
G HEESUNG Specification No. Rev. 1
HSOF 9021-US13 Page: 2110
1. SCOPE
1.1 APPLICATION
This specification covers the requirements for the single mode optical fiber cable
intended for duct.
1.2CALBE DISCRIPTION
1)The cable structure is completed by the application of a swellable tape wrapping,
peripheral strength member which with the core, are covered by an overall PE jacket.
2)Cable core description
The cable core consist of single mode color coded fibers, thixotropic jelly filled,
color coded loose tubes, PE filler (if necessary), SZ stranded around the dielectric
central strength member with water blocking yarn.
2. OPTICAL FIBER IN THE CABLE
2.1 The operating wavelength region of Single mode around 1310nm & 1550nm.
2.2Material of the fibers
The fiber shall be made from high grade silica glasses and the primary coating shall
be made from UV curable acrylate of equivalent material. A protective UV cured
acrylate coating shall be applied over the fiber cladding and it shall be able to
removed mechanically or chemically.
Core Si02+Ge02
Cladding Si02
Primary Coating Dual layers of UV curable acrylate (or equivalent)
(10 HEESUNG SpeciFcation No. Rev. 1
HSOF 9021-US13 Page: 3110
2.3Temperature range
Transportation and storage temperature -400C to 70°C
Installation temperature -10°C to 500C
Operating temperature -400C to 700C
2.4 Characteristics for fibers in the cable
The optical, geometrical and mechanical performance of the optical fiber shall be in
accordance with Table 1.
Table 1 : Characteristics for single mode fibers
ITEM
SPECIFICATION
Type of Fiber
Single Mode Fiber
According to ITU-T Q 652
Attenuation
5 0.40 dB/km @ 1310 nm
5 0.30 dB/km @ 1550 nm
Cladding Diameter
125 ± 1 um
Cladding Non -circularity
5 1 %
Coating Diameter
250 ± 15 um
Core Diameter
nom. 8.3 um
Core/Cladding concentricity error
5 0.8 um
Mode Field Diameter
9.3 um ± 0.5 um @ 1310 nm
Cut-off
Wavelength
A ccf (22m of a cabled fiber)
Max. 1260 nm
A cf (2m of a fiber)
1150- 1350 nm
Chromatic
Dispersion
Coefficient
@ 1285 -1330 nm
Less than 3.5 ps/nm.km
I@ 1550 nm
Less than 18 ps/nm.km
Proof test level
100 kpsi
Attenuation
Bending Loss
(Mandrel Dia.)
75 mm x 100 turn
5 0.05dB @ 1310 nm
5 0.1dB @ 1550 nm
32 mm x 1 turn
5 0.5dB @ 1550 nm
Index of Refraction
nom. 0.36 %
Coating Strip Force
1.3N 5 F 5 8.9N
Fiber Curl
z 2 meters
Dynamic Fatigue Parameter (nd)
Z 20 (typical value)
Static Fatigue Parameter (n5)
z 20 (typical value)
(10 HEESUNG SpeciEcation No.
Rev. 1
HSOF 9021-US13 Page: 4110
3. CABLE CONSTRUCTION
The construction of the cable shall be in accordance with Table 2.
Table 2 : Cable Construction
ITEM
DESCRIPTION
Number of Fiber
48
Type of Fiber
Single mode See Table 1
Number of Tubes
4 ( Optical fiber allocation shall be as Table 3 )
Number of Fibers per Tubes
12
Type of Loose Buffer Tube
PBT ( Polybutylene Terephthalate )
Type of Inner Jelly Compound
Thixotropic type Jelly Compound [ in loose tube ]
Number of Filler Rods
Manufacturer's option [ Natural color ]
Water Blocking Material
Water swellable yarn [ around CSM ]
Central Strength Member
Fiber Reinforced Plastic [ FRP ]
[ CSM ]
With PE coating ( if necessary)
The required numbers of fiber filled loose tube and
filler rod [ if any ] are S-Z stranded tightly around
S-Z Stranding
the central strength member. The loose tube &
filler(s) shall be stranded in one layer over the
central strength member.
Water Swellable Tape
Core Wrapping Tape
The tape shall be applied longitudinally over the
tube to prevent water ingress.
Glass yarn
Peripheral Strength Member
A suitable number of yarn shall be used to provide
the demanded tensile load with central strength
member.
Rip cord
One rip cord
To provide the easy cable entry
Speatftatton "No.
HSOF 9021-US13
Rev. 1
Material: Black MDPE Page: 5110
Thickness: Nom. 1.0 mm
Outer Jacket
Jacket yield strength
- unaged : min. 19.3MPa
- aged(90°C/96hr) : min. 14.5MPa
i) HEESUNG Speciffcation No. Rev. 1
HSOF 9021-US13 Page: 6110
Table 3 : Optical Fiber Allocation
No. of
Position of Loose Tube & Fiber No. per Loose Tube
Fibers
1
2
3
4
5
6
7
8
9
10
11
12
48
12
12
12
12
4. Fiber and Loose Buffer Tube Identification
The color code of the loose buffer tubes and the individual fibers within each loose
buffer tube shall be in accordance with Table 4-a, 4-b.
Table 4-a : Color Coding of Optical Fiber
Number
Color
Number
Color
Number
Color
1
Blue
5
Grey
9
Yellow
2
Orange
6
White
10
Violet
3
Green
7
Red
11
Pink
4
Brown
8
Black
12
Aqua
Table 4-b : Color Coding of Loose Buffer Tube
Number
Color
Number
Color
1
Blue
5
Yellow
2
Orange
6
Black
3
Green
7
White
4
Brown
8
Red
HEESUNG Specification No. Rev. 1
HSOF 9021-US13 Page: 7/ 10
5. Physical / Mechanical / Environmental Performance & Tests
The physical, mechanical and environmental performance of the cable shall be in
accordance with Table 5.
Unless otherwise specified, all attenuation measurements required in this section shall
be performed at 1550 ±20nm.
The completed cable shall be capable of meeting the following requirements.
The repeatability of the measurement system shall be within ±0.05 dB.
Table 5 : The physical, mechanical and environmental aerformance
ITEMS
Test Method & Acceptance Criteria
o Test method: IEC 794-1-E1
-. Applied tensile load : 270ON
-. Duration of loading : 10minutes
Tensile Strength
-. Mandrel diameter: 30D (D=cable diameter)
• Acceptance criteria
-. Attenuation increment : No change (after testing)
-. No jacket cracking & fiber breakage
o Test method : IEC 794-1-E3
-.Applied load: 1000N
-. Plate size: 100mm x 100mm
Crush
-. Duration of loading : 5minutes
• Acceptance criteria
-. Attenuation increment: 5 0.1 dB
-. No jacket cracking & fiber breakage
o Test method : IEC 794-1-E4
-. Height of impact: 1m
-. Drop hammer mass: 10N
-. No. of impact per point Atime
Impact Resistance
No. of impact point:10points (100mm interval)
• Acceptance criteria
-. Attenuation increment: 5 0.1 dB
-. No jacket cracking & fiber breakage