Loading...
HomeMy WebLinkAboutAddenda - BID - 5792 LINCOLN CENTER MULTI UNIT HVAC AND ROOF REPLACECity of Fort Collins Administrative Services Purchasing Division CITY OF FORT COLLINS ADDENDUM No. 3 BID #5792 LINCOLN CENTER HVAC & ROOF REPLACEMENT SPECIFICATIONS AND CONTRACT DOCUMENTS Description of Bid #5792 Lincoln Center HVAC & Roof Replacement OPENING DATE: July 7, 2003, 3:00p.m. (Our Clock) To all prospective bidders under the specifications and contract documents described above, the following changes are hereby made. A. Specifications SECTION 01560 TEMPORARY CONTROLS 3.01 GENERAL add the following F. Permanent and / or temporary HVAC for the dressing rooms shall be operating at least 4 hours prior to performers occupancy of the dressing rooms. 3.02 NOISE CONTROL add the following C. Construction activities that create disturbances in the performance halls including but not limited to noise, dust, vibration will not be allowed during performances. SECTION 15950 4. CONTROL INSTRUMENTS AND EQUIPMENT add the following B7. The thermostat for VAV-1, located in the basement shall have a manual pushbutton override, with time of override remotely programmable by the operator through the DDC system SECTION 15950 13. SEQUENCE OF OPERATION add the following B. Add the following after the last sentence. The LINT controller will communicate via the N2bus (provided by contractor) to the NCM. NCM shall be provided by the owner. All point definitions to be built up at the front end by the city facilities control staff. 136. after RTU add and VMA B. Drawings Sheet X1 There are two (2) layers of existing roofing on the lower roof; roofing, insulation and flashing on the south side of the new parapet wall shall be removed to the wood deck below. There is no known asbestos in the roofing, flashing or insulation. 215 North Mason Street • 2nd Floor • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6775 • FAX (970) 221-6707 Existing piping, ductwork and conduit are to remain or be replaced after re -roof unless otherwise noted on the plans. The W14X30 on the south end is existing to remain. Sheet Al Install new roof drains, tapered insulation, and flashing on the roof south of the new parapet that previously was to have been re -roofed. Sheet S1.2 The support column at the existing beams are existing. The new W12x26 shall be the entire width of the space with a new column support on the parapet wall and attached per detail 3/S2.2 The C8x11.5 shall be continuous along the east wall and broken or notched at the existing beams after verifying exact precast wall panel locations. Attachments Revised roof plan Revised beam seat detail If you have questions please contact John Stephen, CPPB, Senior Buyer, at 970-221-6777. RECEIPT OF THIS ADDENDUM MUST BE ACKNOWLEDGED BY A WRITTEN STATEMENT ENCLOSED WITH THE BID/QUOTE STATING THAT THIS ADDENDUM HAS BEEN RECEIVED. 2 AFMX LOCATION OP past &AS LME 0~--NEW FLLLr ADHEMD TO KMAR9--� NWALV OVER COVERBOARD &VIN TAMb= M'ILATk% TO Ekl.9T t DRAM O!WOOD DECKN& EYATN rx j TIM WALL TO 1 1 RD PATCH MOCK 4 FPECMT W L WITH GROUT AT TEMPORARY CONTRACTOR TO PWC M �L ACS PREFIMT "D CAP WM4 W ITHDRIW& TEST TO EXISTMG OR NEW TO MATOa � mi-OIIT CAPACITY 4 �v 1 P x TE CsTR W, CEILN�IEe LOCATION mew EI TOIiZ TOOOLM iP DURING C�l6Ta2aCTICN I ICI TOP OF F MF RE, STRUGT. 1 IM &TI u:'.m: � j a• asov� RocF \ f ORAIN MAX I V n FAC ExISITING BUELT-Up RooF PATCH ROOF AFTER REMOAW3 TEMPORARY CJWt Ws LNITs R FRAMES NEW ROOF DRAM - TIE Cf LEA7ER TO pd9TMGl sH ROOF DRAM BELOW RDOP 9TR1C71aRE TOP OF ROOF R — IC TILE CVLm \\\ cE1LMG a9EL.OW D.S. FAXF DI GTPSaf1 'E •x Exr. 6V-ATa NIr >. 4 EFDM a WALL OW pp �t�l■IE+i e A .{• METAL G W/ R•IS FaaL MBLLATION 4 PE 'X' W, G7P. W. EW Ei'DI I pML— OF ORAM PM I' DRAM 4 a K CONO AY aN1.O0aG PJ OW RD. 2. THAN ROC+F L zi I , EXISTING BRICK WAI I F11 STANDARD LONG SLOTTED HOLES (2) 1/2"dx8' A36 RODS. 8' GA, EM13EODED 4 1/2" E17aklm IN r Am WITH STANDARD %ormc HILTI HIT MY 20 SYSTEM HOLES IN BEAM BOTTOM FLANGE / POCKET FXL4TIMC ARICK -/ SINGLF SIDF TFFION WALL PROVIDE A" x 6" x 3" SLIDE -BEARING BERWEEN 1'-O" RFARIN(, PI ATF nN BEAM AND BEARING PLATE NON -SHRINK GROUT TYPICAL S2. PARTIAL REVISED LINCOLN CENTER HVAC REPLACEMENT FORT COLLINS, COLORADO PROJECT No. 22117 JUNE 25, 2003 WEEKS & ASSOCIATES