Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RESPONSE - BID - 5791 CHEMICAL STORAGE BUILDING (4)
BID PROPOSAL BID #5791 CHEMICAL STORAGE BUILDING BID OPENING: MAY 29 2003 3.00p m (our clock) WE HEREBY ENTER OUR BID FOR THE CITY OF FORT COLLINS REQUIREMENTS FOR CHEMICAL STORAGE BUILDING PER THE BID INVITATION AND ANY REFERENCED SPECIFICATIONS: The City Of Fort Collins is requesting bids for one chemical storage building with 2 hour fire rating for Natural Resources Department located at Nix Farm, 1745 Hoffman Mill Road, Ft Collins, CO. per the attached specifications. All shipping must be FOB Destination and included in the lump sum bid. Any questions regarding this bid should be directed to John Stephen, CPPB, Senior Buyer at (970) 221-6775. BID SCHEDULE Provide one non-combustible storage locker shipped completely built, including freight, per attached specifications: LUMP SUM $ 2� .1 • �V Firm Na Signatu Printed/Name L. O Address �r �i ``[��1 l W Telephon2e�__ �t�CJ % ��j • POE), 5 aV Fax # ro 3 John Lang & Associates, Inc. 303/273-5813 FAX: 303/384-3636 SAFETY STORAGE`' INC. 2301 Bert 11•A'4 HCMWV,, CA 9WO Ph; (931) 837-NM FAX (831) 837--7406 Mr. James B. O'Neill II City of Ft. Collins PO Box 580 Ft. Collins, CO 80522-0580 P: 970/221-6775 F: 970/221-6707 Re: Chemical Storage Building, Bid #5791 May 29, 2003 John Lang & Associates, Inc., on behalf of Safety Storage, Inc., is pleased to submit the following budgetary quotation for the manufacture of One (1) Model 1612FR Two -Hour Fire -Rated Safety Storage, Inc. Building, equipped with the optional items you requested. The following quotation will be honored for a period of sixty (60) days from the date of this quote. Included: 1. Budgetary price quotation 2. Freight quotation 3. Specifications 4. Building schematic 5. Terms and conditions 6. Commercial credit application One (1) Model 1612FR Safety Storage, Inc. Building will include: • Steel Floor Grating • One (1) Three-Hr.Fire-Rated Double Door, 60eWx 80"H with Self Closers • Two (2) Air Inlet Vents with 3-Hr. Fire Dampers and Adjustable Registers • R-11 Insulation in Ceiling, Exterior Walls and Floor • R-12.5 Insulation in Double Door • One (1) Load Center LC3 (NEMA 3R), 220V/1 Phase • One (1) Explosion Proof (EP) Convection Heater (12,000 Btu) • One (1) EP 450 CFM Exhaust Fan with non-EP Exterior Fan Switch and Adjustable Register • Two (2) EP Interior Light (150W) with non-EP Exterior Light Switch • One (1) Steel Ramp, 48*W x 88"L • Seventy-two feet (72') Stainless Steel Adjustable Shelving, 16" Deep with 1' Containment Lip Budgetary Subtotal for One (1) Model 1612FR Building, FOB Hollister CA S26 159.0( Estimated Freight Charges for One (1) Model 1612FR [destination: Ft Collin CO 80524') S2 650 00 'The freight charges quoted are for the transportation of One (1) Model 1612FR Safety Storage Building and are an estimate only, due to the current fluctuations in the costs of fuel. Once the building is ordered freight costs will be revisited. Freight and Off -Loading Charges, Permitting, any Required Approval Fees and Taxes Are Not Included. Please refer to the attached Safety Storage, Inc. Terms & Conditions. 019".1995,19w. 199781999 ey Saf&y SWW, Im. ... AO RHO Reserved John Lang & Associates, Inc. 303/273-5813 FAX: 303/384-3636 The above unit is being quoted per the limited specifications supplied by you. Due to this lack of information regarding materials, handling and quantities being stored in the unit, as well as potential non-compliance with code requirements for proper storage and handling of hazardous chemicals, City of Ft. Collins (CO) and its clients, assigns and successors release Safety Storage, Inc. and John Lang & Associates, Inc. from any and all liability for improper use of the unit specified. Delivery Terms are F.O.B. Origin. Please indicate shipping preference on your purchase order. Please issue and mail your purchase order directly to: Safety Storage, Inc. P.O. Box 440 Charleston, IL 61920 A copy of the purchase order may be faxed to: Safety Storage, Inc. (217)345-4428 Please see the attached sheets for our "Standard Terms and Conditions," which are integral to this quotation. If I can be of any more immediate assistance, please feel free to call me at (303) 273-5813, fax: (303) 384-3636, or email: iohno(adimensional.com . Thank you very much for your request for quotation, and I know you will be highly pleased with your Safety Storage, Inc., building. L. Offersen Lang & As fates, Inc. cc: Eric Reinbolt, SSI Headquarters 0 1994,19M 19M. 1997 & 1998 By Sat* gimp, Inc _ AR Fbgtft Pp SAFETY STORAGE BUILDING - MODEL 1612FR City of Ft Collins, CO Bid #5791 May 29, 2003 STANDARD FEATURES: • Factory Mutual System ("FM') Approved & Labeled. . Interior Square Footage: 140 sq. ft. • Exterior Dimensions (Nominal LxWxH): 16' x 12' x 9' (Note: Accessories may alter dimensions, please fefer to building diagram.) • Interior Dimensions (LxWxH): 14'1' x 10' x 7'1' • Exterior Wall Construction: Weatherproof, bi-directional 2-hour fire -rated noncombustible construction, per Underwriter Laboratories CUU) Fire Resistance Rating Design Number U425, with two (2) layers of UL Classified fire -resistive gypsum wallboard fastened to the interior & exterior sides of corrosion protected steel studs. The interior & exterior surfaces Gad with corrosion resistant galvannealed steel sheets for maximum durability, weather resistance & rigidity. No sprayed or troweled cementrtfous material (classified only as a fireproofing agent) is used • Sump Wall Construction: Weatherproof, bi-directional 2-hour fire -rated noncombustible construction, same as exterior walls, utilizing interior continuously welded heavy gauge steel sheets for maximum spill containment protection. No sprayed or troweled cemenfitlous material (classified only as a fireproofing agent) is used. • Roof/Ceiling Construction: Weatherproof, bi-directional 2-hour fire -rated noncombustible construction, same as exterior walls, utilizing interior galvannealed steel sheets & exterior heavy gauge steel roof sheets for maximum durability and weather resistance. Roof/ceiling permanently attached to exterior walls. No Lightweight exterior steel roof skins, plywood, rubber membranes, or cemenfi6ous material (sprayed or troweled) are not used. • Three-hour fire -rated door(s), UL Classed & Labeled, equipped with UL Listed self -closers) and UL Listed exterior security lock(s) with keyless interior safety release lever(s). • Screened Air Vent(s): Air inlet vent(s) equipped with UL Classified & Labeled 3-hour rated fire dampers with louvers & screens to provide air flow but prevent bird & animal entry. Dampers have a galvanized steel frame, curtain -type galvanized steel blades, and a UL Listed 165°F fusible link. • Building Base: Open channel construction for visual inspection under building. Coated with a protective undercoating for maximum corrosion resistance. Cranetforklift openings for ease in off- loading and relocation. • Built-in 7-inch deep Secondary Containment Sump with chemical -resistant epoxy coating. • Internal Spill Containment Capacity: 590 gallons (30% of total storage capacity). • Interior Finish: High solids, chemical -resistant epoxy coating with an aliphatic polyurethane topcoat. • Exterior Finish: High solids, chemical -resistant epoxy undercoat with a heat reflective gloss -white aliphatic polyurethane topcoat. • Four (4) Hold-down Brackets (structural steel angles) for wind and seismic anchoring. • Static Grounding System: One (1) exterior grounding connection, one (1) 10-foot long 51W diameter copper -clad steel grounding rod, one (1) #4AWG copper conductor, and grounding lug(s). • Signage: Permanent all -metal D.O.T. hazard classification placard set(s) with rust -proof aluminum holder & stainless steel clips; and, pressure sensitive NFPA 704 Hazard Rating Sign(s). • Tare Weight: 17,150 lbs. DESIGN LOADS: • Roof Snow Load: 40 psf • Wind Load: 110 mph, Exposure C • Floor Live Load: 500 psf • Floor Live Load Storage Capacity (Weight): 70,000 lbs. (Uniformly Distributed) • Seismic Condition: Zone 4 or Performance Category E 1 /98 1 © 1994, 1995, 19M. 1997 & ism 6y SAFETY STORAGE, INC. u i o�Q oc M=n fV L� O 0 r W u m O m o4z Q a_ LLJ W a ¢> $ DO LLI d N ^ a � W l^L � b vF1 I L L z: Iwo W EL m N w J MCN 7�X0 a 77�� a JwJ g ' LcJJ C�u R W v Z R Z�1hNm x< W< rCi y�8tt < vK2o�aggnN c s &yFj q3W (n w F' J o� r S � �i 8 Z i s Z U � Val rk W. z La I, O W LLI�i J �NhnJ1 a V I I�i � N y p to (� N L� C K V O W W V Z S J JLLJ 1 U. a Z LL �LLy ® ` ca < .00 X .GL a I SMON f O I I rn g I � x I I I � o I 3 I Z lc5, m .lid I I 1 I �x I S Allall of 01 ,00'0ZL Iry N 1J,Z9'4Z l .00'L CD L_s Jg30,LYf£I .OB HO „00"i01 ~ Li JOOL,SZ'Lf L � Mi at¢r-aw 'ON `JNIAVW N lL O N CO 0 Q O 0- W 0_ J I W W � 0] O Ln W W w z � : Q Q LL Z U O Ul ® W F- Q S J Z 5 a�a ll� ,00'ti0l y p �3 S W wtz p OS e Ckf I� Q E! N CD W O ac¢r-an "ON 9NJAVW