Denver Truck Sales is pleased to bid on the above contract, #5710, as amended by
addendum # 1. The following description of the tank, pump system and control units will
follow your specifications sheet, detailing how our tank will comply with each of your
requirements. Should questions arise during the evaluation process, please call for
clarification. We look forward to building and mounting this tank to your chassis.
Street Flusher Tank, Pumps & Control System, Mounted, tested and approved by
Representatives of the City of Ft. Collins:
FOB Denver Truck Sales, Denver, CO $44,950.00
Respectfully submitted,
``1Bill Ray
Overflow pipe: 3" minimum diameter, extending
up into the manhole.
Meets specs
Hydrant fill: 2-1/2" fill pipe with 5 —6" anti -siphon
air gap. Removable strainer at inlet end.
Meets specs
Dome Rails: Dual safety rails, full length of tank.
Epoxy coating: Interior of tank shall be properly
Design does
require ful
prepared, cleaned and coated with an epoxy
Dome rail
finish designed to withstand the corrosive action
of liquid deicer compounds.
Meets specs
Water Tank
Steel rails welded to tank and spring -mounted to
6.4
Mounting:
truck frame on hardwood cushion strips or other
Meets
acceptable flexible mounting system.
specs
Hydrostatic, load sensing system, driven from
crankshaft driven Rexroth A10VO (or equivalent)
Meets specs
pump.
Hydraulic system must incorporate flow and
6.5
Hydraulic
pressure limiters or relief valves designed to
Meets specs
System:
prevent damage to pump and motor.
Water pump drive motor shall be a Rexroth bent
axis, AA21F motor (or approved equivalent) sized
Meets specs
to the hydraulic pump and meeting the power
requirements of the water pump.
Minimum 30 gallon hydraulic reservoir with 10
micron, spin -on, oil filter with 15 psi internal
Meets specs
bypass valve mounted in flusher hydraulic system
return line between hydraulic pump and tank.
Shut off valve: Ball valve, mounted on tank in
flusher hydraulic system suction line.
Hydraulic oil cooler: Radiator mounted cooler
designed to keep hydraulic oil under 160"F during
Meets specs
full operation with an ambient air temperature of
6.6
Hydraulic
100'F. Unit cooled by an electric fan is
Reservoir:
acceptable, but must operate only when water
system is functioning.
Reservoir must be equipped with a thermometer
and an oil level sight gauge.
Meets specs
Provision for City -installed deicer system:
- Extra 2" female bung with 100 micron mesh
screen for deicer oil pump suction line.
- 1"deicer oil pump return line plumbed at
Meets specs
opposite end of tank from deicer suction. Return
Meets specs
line must have a dip tube to avoid oil aeration.
not
length
0
Must be designed to produce 800 GPM at 150 psi
at 1200 RPM engine speed. Water pressure
Meets specs
measured at the nozzles.
6.7
Water Pump:
Impeller and case must be of cast iron. Service
or replacement of impeller shall not require
Exception
disassembly of plumbing or removal of pump from
see attached
chassis.
Flusher nozzles — fan type, 3-piece fully
adjustable bronze duckbill style.
Meets specs
Sprinkler nozzles — 180 degree upright adjustable
fan spray nozzles.
Meets specs
Nozzles must be equipped with electric over air
valves controllable from the operator's station.
Meets Specs
6.8
Nozzles:
Plumbing to nozzles shall be 3" on manifolds and
Meets Specs
2-1/2" to individual heads.
Nozzle locations:
- Below the front bumper, one flushing nozzle on
each side.
Meets Specs
- Midships, one flushing nozzle on each side.
- Rear, one sprinkler nozzle on each back corner
Meets Specs
of the tank.
Meets Specs
Automatic overspeed protection designed to
6.9
Overspeed
prevent damage to system components when
Protection:
engine speed is outside the normal operating
Meets Specs
range. See Controls.
Automatic
Water Pressure
Sensing and control system designed to allow for
Meets specs
6.10
Control
constant water pressure within a vehicle speed
System:
range of 5 — 25 mph. See Controls.
Low Water
Shutoff system must warn operator when water
6.11
Shutoff
level is low and then automatically stop flushing
System:
before water pump can be damaged.
Meets Specs
All controls and indicators shall be mounted in the
cab, grouped logically and within easy reach of
Meets Specs
the operator. At a minimum the following devices
shall be installed.
Pressure control: dial -type controller, 20 — 150 psi
Exceptions e
6.12
Controls:
range'
attached lette
Pressure gauge: 0-300 psi
Manual shut-off switch.
Exception, s e
Individual switches for each nozzle.
attached let e
Switches and controls for any other installed
Meets Specs
equipment.
Meets Specs
etter
7
Full -width fenders covering rear truck tires.
Formed steel channel bumper at rear.
6.13
Other
Ladder access to top of tank.
Equipment:
Hose reel: Electric rewind with manual backup,
Meets Specs
with 100' of 1-1/2" rubber hose and adjustable
brass nozzle. Control valve must be mounted
between hose reel and tank.
Lighting must comply with applicable Federal and
State regulations.
Meets specs
6.14
Lighting and
Stop, tail, and clearance lights must be recessed
Safety:
into corner plates mounted on tank. Stop and tail
lights furnished by truck manufacturer must be
Meets specs
installed on the truck frame.
All electrical wiring must be run in conduit.
Wiring &Wiring
All wire connections must be made in water p roof
Meets Specs
6.15
Connections:
fittings designed for that purpose or be soldered
with shrink -type water proof covering. No crimp-
Meets specs
on connections will be accepted.
Water tank shall be painted white. Hydraulic oil
6.16
Paint:
tank and rear fenders shall be painted black.
Contact the City with any other paint and finish
Meets Specs
concerns and questions.
Minimum one-year manufacturer's warranty on
tank and flushing system. Buyer will be supplied
Meets specs
with individual component warranties if those
6.17
Warranty:
exceed one year.
Epoxy coating on inside of tank must be
warranted, in writing, not to peel, flake or
Meets Specs
otherwise fail to adhere to the inner tank surface
for a period of five years from delivery date.
Unit must be delivered with flusher operator's
6.18
Manuals:
manual and operating and parts manuals for tank,
pumps, motors, and control systems.
Meets Specs
A. Poly water tank. Tank must be baffled and meet the general
specifications of a metal tank. Provide a complete description
along with pricing for this option.
B. Water cannon. 2-1/2", with minimum 60 deg up/down, 75 deg
6.19
Options:
left/right motion, with adjustable nozzle. Remote controls mounted
inside the cab.
Provide pricing for unit, cab controls and mounting of cab controls.
Cannon mounting location will be specified at time of order.
D
C. Overhead rotating beacons. Two Target Tech 415011-02SB
units mounted on a light bar on the truck cab. One identical unit
mounted at the rear of and below the top of the tank.
Provide pricing for Target Tech units, required mounting brackets,
wiring (in conduit), in -cab controls and labor to install.
D. Remote adjustable water nozzles. Normally closed, adjustable
for angle and thickness of water stream. Electric over air valve
controllable from the cab. Nozzle adjustments controllable from
the cab. Price as a replacement for specified nozzles, including
any additional wiring and controls.
6.0 SPECIFICATIONS: Street Flushing Unit
6.1 Equipment bid on this proposal must meet or exceed the following minimum requirements.
Any exceptions must be noted and listed on a separate sheet.
General: The following specifications describe a 4,000 gallon, low profile steel tank mounted
on a cab/chassis and equipped for street flushing. All specifications shall be considered as
minimum, and all bids equivalent or exceeding these specifications will be considered. The City
may require on -site demonstrations and evaluations of proposed equivalent equipment before
making a final award. Complete and up-to-date tank and flushing system specifications must
accompany bid.
Tank will be mounted on a new Freightliner Condor cab/chassis with a 144" CA dimension and
measuring 109" after center of an am ax as. ruc w uppe with an A ison 0
ss on and setup for an engine- driven PTO. Successful bidder will be responsible for
delivering the completed unit to the City of Fort Collins.
Installation of tank and flung system are the responsibility of the successful bidder. The City
will install a deicer system n the unit after delivery.
No.
Item
Description
Meets Spec?
6.2
Quantity:
One (1) unit
Truck mounted, low -profile, elliptical steel tank
Capacity: 4,000 US gallons
Shell: Constructed of 7 gauge steel, ASTM 569
Heads: dished and flanged heads, welded inside
and out
Y
Surge plates: Minimum of 3 plates. Constructed
of 7 gauge steel, ASTM 569, dished and flanged.
Plates must have staggered access holes and
drain cutouts which will allow tank to be
completely emptied.
Manhole: Minimum 22" diameter with gasket and
6.3
Water Tank:
quick -release band clamp.
Sump and suction lines: Sump with anti -vortex
baffles, located in tank bottom. One 5" fitting and
stainless steel pipe from sump-IrLflusar system
pump. One 2" pipe fitting with plug for later use
as fRe suction line for a deicer system.
\ /
Note: To allow unrestricted access to fittings and
I/
drains, sump must be located with at least 12" of
clear space laterally and vertically from frame rails
and crossmembers, driveline, suspension and
other components.
Sight gauges: Tube type sight gauges mounted
on the front and rear tank bulkheads.
5
Overflow ning� 3" minimum diameter —extending
up intg the inanhole.
Hydrant fill: 2-1/2" fill pipe with 5 — 6" anti -siphon
air gap. Removable strainer at inlet end.
Dome Rails: Dual safety rails, full length of tank.
\ /
Epoxy coating: Interior of tank shall be properly
prepared, cleaned and coated with an epoxy
finish designed to withstand the corrosive action
of liquid deicer compounds.
Water Tank
Steel rails welded to tank and spring -mounted to
6.4
Mounting:
truck frame on hardwood cushion strips or other
/
acceptable flexible mounting system.
Hydrostatic, load sensing system, driven from
crankshaft driven Rexroth A10VO (or equivalent)
pump.
Hydraulic system must incorporate flow and
\
6.5
Hydraulic
pressure limiters or relief valves designed to
r
System:
prevent damage to pump and motor.
Water pump drive motor shall be a Rexroth bent
axis, AA2F motor (or approved equivalent) sized
to the hydraulic pump and meeting the power
requirements of the water pump.
Minimum 30 gallon hydraulic reservoir with 10
micron, spin -on, oil filter With 15 psi internal
bypass valve mounted in flusher hydraulic system
return line between hydraulic pump and tank.
J
Shut off valve: Ball valve, mounted on tank in
flusher hydraulic system suction line.
Hydraulic oil cooler: Radiator mounted cooler
designed to keep hydraulic oil under 160*F during
full operation with an ambient air temperature of
,
Hydraulic
100*F. Unit cooled by an electric fan is
6.6
Reservoir:
acceptable, but must operate only when water
system is functioning.
Reservoir must be equipped with a thermometer
and an oil level sight gauge.
Provision for City -installed deicer system:
- Extra 2" female bung with 100 micron mesh
screen for deicer oil pump suction line.
- 1" deicer oil pump return line plumbed at
opposite end of tank from deicer suction. Return
line must have a dip tube to avoid oil aeration.
L
1/
Must be designed to produce 800 GPM at 150 psi
�f
at 1200 RPM engine speed. Water pressure
measured at the nozzles.
6.7 Water Pump:
Impeller and case must be of cast iron. Service
or replacement of impeller shall not require
disassembly of plumbing or removal of pump from
chassis.
Flusher nozzles — fan type, 3-piece fully
adjustable bronze duckbill style.
Sprinkler nozzles — 180 degree upright adjustable
fan spray nozzles,
Nozzles must be equipped with electric over air
valves controllable from the operator's station.
6.8 Nozzles:
Plumbing to nozzles shall be 3" on manifolds and
2-1/2" to individual heads.
Nozzle locations:
- Below the front bumper, one flushing nozzle on
each side.
- Midships, one flushing nozzle on each side.
- Rear, one sprinkler nozzle on each back corner
of the tank.
Automatic overspeed protection designed to
6 9 Overspeed
Protection:
prevent damage to system components when
\ j
engine speed is outside the normal operating
range. See Controls.
/y
Automatic
6.10 Water Pressure
Sensing and control system designed to allow for
—
Control
constant water pressure within a vehicle speed
\�
System:
range of 5 — 25 mph. See Controls.
Low Water
6.11 Shutoff
Shutoff system must warn operator when water
System:
level is low and then automatically stop flushing
before water pump can be damaged.
All controls and Indicators shall be mounted In the
cab, grouped logically and within easy reach of
the operator. At a minimum the following devices
shall be installed.
Pressure control: dial -type controller, 20 —150 psi
6.12 Controls:
range.
Pressure gauge: 0-300 psi
Manual shut-off switch.
Individual switches for each nozzle.
Switches and controls for any other installed
7
Full -width fenders covering rear truck tires.
Formed steel channel bumper at rear.
Other
Ladder access to top of tank.
6.13
Equipment:
Hose reel: Electric rewind with manual backup,
v
with 100' of 1-1/2" rubber hose and adjustable
brass nozzle. Control valve must be mounted
I%
between hose reel and tank.
Lighting must comply with applicable Federal and
State regulations.
6.14
Lighting and
Stop, tail, and clearance lights must be recessed
\�
Safety:
into comer plates mounted on tank. Stop and tail
lights furnished by truck manufacturer must be
Installed on the truck frame.
All electrical wiring must be run in conduit.
Wiring & Wiring
All wire connections must be made in waterproof
6.15
Connections:
fittings designed for that purpose or be soldered
with shrink -type water proof covering. No crimp -
on connections will be accepted.
Water tank shall be painted white. Hydraulic oil
i
6.16
Paint:
tank and rear fenders shall be painted black.
Contact the City with any other paint and finish
concerns and questions.
Minimum one-year manufacturer's warranty on
tank and flushing system. Buyer will be supplied
with individual component warranties if those
6.17
Warranty:
exceed one year.
Epoxy coating on inside of tank must be
warranted, in writing, not to peel, flake or
otherwise fail to adhere to the inner tank surface
for a period of five years from delivery date.
Unit must be delivered with flusher operator's
6.18
Manuals:
manual and operating and parts manuals for tank,
pumps, motors, and control systems.
A. Poly water tank. Tank must be baffled and meet the general
specifications of a metal tank. Provide a complete description
along with pricing for this option.
B. Water cannon. 2-1/2", with minimum 60 deg up/down, 75 deg
left/right motion, with adjustable nozzle. Remote controls mounted
6.19
Options:
inside the cab.
Provide pricing for unit, cab controls and mounting of cab controls.
Cannon mounting location will be specified at tune of order.
E:3
C. Overhead rotating beacons. Two Target Tech 415011-02SB
units mounted on a light bar on the truck cab. One identical unit
mounted at the rear of and below the top of the tank.
Provide pricing for Target Tech units, required mounting brackets,
wiring (in conduit), in -cab controls and labor to install.
�i LRemote adjustable water nozzles. Normally closed, adjustable
d thickness of water stream. Electric over air valve
from the cab. Nozzle adjustments controllable from
ice as a replacement for specified nozzles, Including
al wiring and controls.
N
Denver Truck Sales
5293 Vasquez Blvd.
Denver, CO 80216
(303) 291-0960
June 19, 2002
City of Ft. Collins
ATTN: Jim Hume, Purchasing
Bid #5710, Street Flusher Tank, Pumps and Control System
215 N. Mason St., 2nd Floor
PO Box 580
Ft. Collins, CO 80522-0580
Dear Mr. Hume;
This letter describes how Denver Truck Sales' tank will be constructed to address
each specification listed in your proposal. Each specification will be addressed in order,
by number. Options will be addressed as well, at the end of the specification analysis.
6.2 The tank will be a 4,000 gallon low profile elliptical tank, constructed of Yd' 570
steel, 60" tall and 84" wide, 18 feet long. Baffles will consist of two cross baffles
and one longitudinal baffle for a total of three. Cross baffles will be '/4" steel,
cross -braced and gusseted. Baffles will have 20" offset holes with cutouts in the
bottom. The manway will be 20" to 22", rectangular, with a hinged lid and a
quick release holddown.
6.3 A 3" interior discharge pipe will be fitted from front to rear. All pipes will be
schedule 40. A sump with an anti -vortex baffle will be located in the bottom of
the tank, with a 5" fitting and stainless steel pipe from the sump to the flusher
system pump. At the city's discretion, the 5" pipe may be schedule 40, epoxy
coated. A 2" pipe fitting with plug will be provided for later use with a deicer
system. The sump will be located with at least 12" of clear space laterally and
vertically from frame rails and crossmembers, driveline, suspension and other
components. Denver Truck Sales is not responsible for precise location pending
inspection of the City's truck and its construction. We will adapt the tank to meet
this specification or come as close as possible. The sight gauge will be tube type,
mounted front and rear on the bulkheads. An MCO or equivalent level gauge
overflow pipe of 3" diameter will extend up into the manhole. A hydrant fill 3"
pipe will be mounted, with a 5" to 6" anti -siphon airgap. A removable strainer
will be mounted at the inlet end. A 2 %z" adapter will be supplied.
6.4 Truck will have a full ''/4" thick steel box subframe with three interlocking tank
brackets per side with two high tensile strength bolts and springs at each
7.0 BID PROPOSAL
7.1 UNIT DESCRIPTION
Bid # 5710, Street Flusher Tank & System
Make Rosco I Model MTA-H Year Z002
7.2
BASE PRICE, as specified, per unit 1 $ 49, 389.00
7.3 OPTIONS
A $ Not availa le B $ 7,900.00 C $ 745.00 D $Not availab
8.0 FREIGHT TERMS
Completed unit must be shipped to the City of Fort Collins, FOB destination, freight prepaid. All
freight charges must be included in bid pricing.
9.0 DELIVERY
Delivery will occur 45 rr, Rn days after delivery of cab/chassis. To Rosco
10.0 CONTRACTOR'S STATEMENT
I have read and fully understand all the conditions, specifications, and special instructions herein
set forth above in paragraphs 1.0 through 9.0. 1 hereby agree to comply with all said conditions,
special instructions, and specifications as stated or implied.
n
Signature:
Title:
PrintNa :
Joe Owens
Vice President
Company:
Date:
Macdonald Equipment Company
Street: P.O.
Box 5011, 7333 Highway 85
Phone #: 303/287-7401
City/State/Zip: Commerce City, CO 80037
Fax#: 303/287-7404
ie
10
6.0 SPECIFICATIONS: Street Flushing Unit
6.1 Equipment bid on this proposal must meet or exceed the following minimum requirements.
Any exceptions must be noted and listed on a separate sheet.
General: The following specifications describe a 4,000 gallon, low profile steel tank mounted
on a cab/chassis and equipped for street flushing. All specifications shall be considered as
minimum, and all bids equivalent or exceeding these specifications will be considered. The City
may require on -site demonstrations and evaluations of proposed equivalent equipment before
making a final award. Complete and up-to-date tank and flushing system specifications must
accompany bid.
Tank will be mounted on a new Freightliner Condor cab/chassis with a 144" CA dimension and
measuring 109" after center of tandem axles. Truck will be equipped with an Allison HD4560
transmission and set up for an engine -driven PTO. Successful bidder will be responsible for
delivering the completed unit to the City of Fort Collins.
Installation of tank and flushing system are the responsibility of the successful bidder. The City
will install a deicer system on the unit after delivery.
No.
Item
Description
Meets Spec?
6.2
Quantity:
One (1) unit
Truck mounted, low -profile, elliptical steel tank
Meets Specs
Capacity: 4,000 US gallons
Shell: Constructed of 7 gauge steel, ASTM 569
Meets Specs
Heads: dished and flanged heads, welded inside
and out
Surge plates: Minimum of 3 plates. Constructed
Exception,
of 7 gauge steel, ASTM 569, dished and flanged.
attached le
Plates must have staggered access holes and
drain cutouts which will allow tank to be
completely emptied.
Manhole: Minimum 22" diameter with gasket and
Exception,
6.3
Water Tank:
quick -release band clamp.
attached le
Sump and suction lines: Sump with anti -vortex
baffles, located in tank bottom. One 5" fitting and
4" suction
stainless steel pipe from sump to flusher system
attached le
pump. One 2" pipe fitting with plug for later use
Meets Specs
as the suction line for a deicer system.
Note: To allow unrestricted access to fittings and
drains, sump must be located with at least 12" of
Meets Specs
clear space laterally and vertically from frame rails
and crossmembers, driveline, suspension and
other components.
Sight gauges: Tube type sight gauges mounted
on the front and rear tank bulkheads.
Meets Specs
ee
ter
ee _
ter
ee
ter
5