Loading...
HomeMy WebLinkAboutBID - 5743 LP CONDUIT PVC 4 INCHES (2)Citv of Fort Collins Administiative Services Purchasing Division CITY OF FORT COLLINS INVITATION TO BID BID #5743 Sealed bids will be received and publicly opened at the office of the Director Of Purchasing and Risk Management, PO Box 580, 215 North Mason St., 2nd floor, Fort Collins, Colorado 80521, at the time and date noted on the bid proposal and/or contract documents. If delivered, they are to be delivered to 215 North Mason Street, 2nd Floor, Fort Collins, Colorado 80521. If mailed, the address is P.O. Box 580, Fort Collins, 80522-0580. Bids must be received at the Purchasing Office prior to 2:00 p.m. (our clock), October 23, 2002. Special Instructions All bids must be properly signed by an authorized representative of the company with the legal capacity to bind the company to the agreement. Bids may be withdrawn up to the date and hour set for closing. Once bids have been accepted by the City and closing has occurred, failure to enter into contract or honor the purchase order will be cause for removal of supplier's name from the City of Fort Collins' bidders list for a period of twelve months from the date of the opening. The City may also pursue any remedies available at law or in equity. Bid prices must be held firm for a period of forty-five (45) days after bid openings. Submission of a bid is deemed as acceptance of all terms, conditions and specifications contained in the City's specifications initially provided to the bidder. Any proposed modification must be accepted in writing by the City prior to award of the bid. Only bids properly received by the Purchasing Office will be accepted. All bids should be clearly identified by the bid number and bid name contained in the bid proposal. No proposal will be accepted from, or any purchase order awarded, to any person, firm or corporation in default on any obligation to the City. Bids must be furnished exclusive of any federal excise tax, wherever applicable. Bidders must be properly licensed and secure necessary permits wherever applicable. Bidders not responding to this bid will be removed from our automated vendor listing for the subject commodities. The City may elect where applicable, to award bids on an individual item/group basis or on a total bid basis, whichever is most beneficial to the City. The City reserves the right to accept or reject any and all bids, and to waive any irregularities or informalities. Sales prohibited/conflict of interest: no officer, employee, or member of City Council, shall have a financial interest in the sale to the City of any real or personal property, equipment, material, supplies or services where such officer or employee exercises directly or indirectly any decision - making authority concerning such sale or any supervisory authority over the services to be rendered. This rule also applies to subcontracts with the City. Soliciting or accepting any gift, gratuity, favor, entertainment, kickback or any items of monetary value from any person who has or is seeking to do business with the City of Fort Collins is prohibited. 215 North Mason Street • 2nd Floor • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6775 • FAX (970) 221-6707 REV. SYM: C SPECIFICATION FOR PLASTIC CONDUIT SPEC. 9366-200 1.0 SCOPE This Specification establishes the minimum requirements for 2", 4", and 5" plastic conduit to be used with electric power conductors and cables for aboveground use indoors or outdoors exposed to weather and sunlight at 5,000 feet altitude, and for underground use by direct burial or encasement in concrete. 2.0 APPLICABLE DOCUMENTS This Specification is in accordance with the requirements of ASTM F512, titled "Standard Specification for Smoothwall Poly(vinyl Chloride) (PVC) Conduit and Fittings for Underground Installation', with exceptions as noted in the following paragraphs. 3.0 REQUIREMENTS 3.1 GENERAL REQUIREMENTS FOR DESIGN All conduit furnished under this Specification shall, unless otherwise specified, comply with ASTM F512. In case of conflict, the requirements of the following documents shall apply in the priority shown: I. This Specification. 2. ASTM F512. 3. Other referenced standards. 3.L1 MATERIAL Conduit furnished under this Specification shall be made of virgin Polyvinyl -chloride (PVC) compound conforming to ASTM D1784 with the minimum cell classification shown in Table I of this Specification. Chemical resistance shall be in accordance with ASTM D 1784, suffix A or B. 5 366-200 ` REV. SYM: C TABLE ASTM D1784 Designation Order No. Property and. Unit Value ASTM Test Method Minimum ASTM D 1784 Cell Classification Cell Limit No. Base resin Poly (vinyl I Homo of mer Chloride NA 1 Impact strength (Izod)min ft-Ih/in. of notch 2 065 D256 2 Tensile strength, 3 Min psi. 5,000 D638 2 Modulus of elasticity 4 in tension, min psi 500,000 D638 >6 Deflection Tempera- ture under load, min 5 264 psi de . F 158 D648 4 Flexural strength min - is 13,000 D790 3.1.2 Virgin compound is defined as compound which has not previously been used to make another product. Reworked material is defined as clean reground or repelletized material generated from a manufacturer's own conduit extrusion, and used by the same manufacturer who generates it. Clean is considered to exclude anything foreign to the specific compound designated by the manufacturer for use under this Specification. Rework material may be used provided that the conduit or fittings produced meet all of the requirements of this Specification. 3.1.3 CONDUIT TYPE Conduit type shall be as specified in Specific Requirements for Design. 3.1.4 WORKMANSHIP The conduit shall be homogeneous throughout and free from visible cracks, holes. foreign inclusions, or other injurious defects. The conduit bore shall be smooth and free from blisters, nicks or other imperfections which could mar conductors or cables. 3.L5 SUNLIGHT RESISTANCE/COLOR The conduit shall contain titanium dioxide pigment to produce a white color with a reflective factor of greater than eighty percent to allow outdoor storage and,or installation at 5.000 feet altitude for an indefinite period without deterioration. 6 366-200 REV. SYM: G 3.1.6 LENGTH Conduit shall be in lengths of twenty feet overall including integral bell. Tolerance of length shall be + one inch (+ 25 mm). 3.2 SPECIFIC REQUIREMENTS FOR DESIGN 3.2.1 CONDUIT DIMENSIONS AND TOLERANCES Dimensions, tolerances and pipe stiffness shall be in accordance with Table II of this Specification. Wall thicknesses shown in Table Ii are based on a minimum modulus of 500,000 psi. TABLE II Serial Number Nominal Size (in.) ASTM Type Wall Thickness Min. In. Average Outside Dia. Inches Out -of - Round 366-200-02 2 DB 120 0.077 2.375+.006 366-200-04 4 DB 120 0.154 4.497 +•006 0:082 366-200-05 5 EB 35 0.126 5.563 + .010 1 0.082 'snaoeo items oevtate trom ASTM F512 3.2.2 BELLED ENDS Each length of conduit shall have an integral belled end. Glued couplings are specifically prohibited. Belled end dimensions shall be based on the clearance fit system defined in Table 2 of ASTM F512 except socket depth and out -of -round requirements shall be in accordance with Table III of this Specification. Belled ends shall be centered on the longitudinal axis to provide a visible shoulder around the entire circumference of the conduit. Both ends of each length of the conduit shall be perpendicular to the longitudinal axis of the conduit, i.e., both ends shall be square cut. TABLE Ill Nominal Size Inches Socket Entrance Inside Dia, Inches Socket Bottom Inside Dia. Inches Socket Depth Inches Min. Max. Out -of -Round 2 2.400+0.006 2.381+0.006 2.250 2.500 0.038 4 4,544 + 0,009 4.509 + 0.009 4.000 4.250 0.082 5 5.614 + 0.010 5.573 + 0.010 5.000 5.250 0.082 oicnucu LCII i] UCVIUIC Iinm A 1 IVI rD 12 366-200 REV. SYM: C 4.0 QUALITY ASSURANCE 4.1 RESPONSIBILITY FOR INSPECTION Unless otherwise specified, the vendor is responsible for the performance of all tests and inspection requirements specified herein. Except as otherwise specified, the vendor may utilize his own facilities or any commercial laboratory acceptable to the City of Fort Collins. The City. reserves the right to perform or witness any of the tests and inspections set forth in this Specification, where such inspections are deemed necessary. If the City, upon receipt of the conduit, deems it necessary to have an independent laboratory perform tests and inspections set forth in this Specification, the manufacturer shall be responsible for all fees incurred in testing if any requirement of the specifications is not met and/or test results for that lot or shipment are not consistent with the manufacturer's certified test results. 4.2 REQUIREMENTS AND TEST METHODS 4.2. t COMPOUND TESTS All the tests required by ASTM D 1784, except the chemical resistance test, shall be made on a compound sample from each new lot or batch. The average value for all the tests made on each batch or lot shall comply with the requirements of paragraph 3.1.1 of this Specification and shall be reported in the certified test report. The chemical resistance test shall be performed annually or when compound suppliers are changed and test results shall be included in the certified test report. 42.2 SUNLIGHT RESISTANCE TESTS Evidence that the compound being used has been qualified in accordance with all tests required by Paragraph 17 of UL 651 shall be included in the certified test report. 4.2.3 PERFORMANCE TESTS Conduit furnished under. this Specification shall pass all tests required by and performed in accordance with ASTM F512 except 2-inch conduit shall have a minimum impact resistance of 40-foot-pounds at 32°F (O°C). 4.2.4 EXTRUSION QUALITY TEST The extrusion quality shall be determined by immersion in anhydrous acetone in accordance with ASTM D2152. Finished duct shall not flake or disintegrate when subjected to this test. Sbb-2UU REV. SYM: C 4.2.5 CERTIFICATION The manufacturer shall furnish to the purchaser certified copies of the results of the tests on each lot or shipment and size of conduit ordered, prior to payment. The certified test report shall state the lot or control number and manufacturer of compound used and shall give specific test values for compound tests, stiffness test, and tests having other than a simple Pass/Fail result. Any conduit tested by the City that does not yield results consistent with the certified test reports for that lot or shipment will be sufficient reason for rejection of the entire lot or shipment. City of Fort Collins purchase order number shall be noted on the first page of each report. Copies shall be sent to the Design section of Fort Collins Light & Power. Unsigned copies are not acceptable even if accompanied by a signed cover letter. 5.0 PREPARATION FOR DELIVERY Conduit shall be bundled by individual size into units suitable for shipping and stacked storage. To protect the bells from deformation caused by pressure from adjacent conduits, each bundle shall be assembled such that bells are all at the same end of the bundle with the bell ends of alternating layers recessed at least the full length of the bells in adjacent layers. The bundles shall be secured using two steel bands with 2" x 4" minimum wooden boards under the bands, sets of bands and boards to be spaced appropriately along the length of the bundle forming adequate crate frames to provide the vertical stacking, frame to frame, to minimize stacked storage deformation with the stack height up to ten feet. Direct contact between the steel bands and the conduit anywhere on the perimeter of the bundle is expressly prohibited. Bundles shall be shipped on an open bed truck. Jbb-NU REV. SYM: F /:\JOR197A�1 Conduit purchased under this Specification shall be of the manufacturer shown below. Manufacturers not listed below may submit written proposals demonstrating compliance with these Specifications for consideration of addition to the accepted manufacturers list prior to the next request for bids. In addition to inclusion on the list below, manufacturer's conduit must also satisfy all requirements of this Specification to be acceptable. MANUFACTURER Can -Tex Certainteed North American Pipe Corporation (NAPCO) 10 366-200 NOV 06 2002 3:48PM 970-"2-5807 P.1 NOV-05-02 03:01P P.01 NORTH AMERICAN PIPE CORPORATION 3348 INDUSTRIAL DRIVE WICHITA FALIS, TEXAS 76306-3135 946- W 4100 November 6, 2002 i Fort Collins WfimkcWc P. O. Box 271005 Fort Collins, Colo. 90327-1005 RoQes: RE: City of Fort Collins Did No. 5743 Quote M 177% Order By 11/15/02 Ship BY 4130103 Anything shipped alter 4/30/03 will have an mculator depeodio6 on Cost of resin up or down. 329,320' 4" Spec. 366-200, Serial 04, Rev.G, .l54 Wall ddckm3 The above price is based on cost of resin u .Nlb., which is approximately 75% of our few malarial cost. We will advise you on 4/30/03 of any increase or decrease in cost of resin. If you have any further questions, pleme let me !slow. Sino"Y' Joyce Korukh PO4W Fax Note 7671 Di1' t 1 TOTPL P.01 n Freight terms: unless otherwise noted, all freight is F.O.B. Destination, Freight Prepaid. All freight charges must be included in prices submitted on proposal. Discounts: any discounts allowed for prompt payment, etc., must be reflected in bid figures and not entered as separate pricing on the proposal form. Purchasing restrictions: your authorized signature of this bid assures your firm's compliance with the City's purchasing restrictions. A copy of the resolutions are available for review in the Purchasing Office or the City Clerk's Office. Request Resolution 91-121 for cement restrictions. Collusive or sham bids: any bid deemed to be collusive or a sham bid will be rejected and reported to authorities as such. Your authorized signature of this bid assures that such bid is genuine and is not a collusive or sham bid. Bid results: for information regarding results for individual bids send a self-addressed, self -stamped envelope and a bid tally will be mailed to you. Bid results will be posted in our office 7 days after the d openi Naha P l James B. O'Neill 11, CPPO, FNIGP Director of Purchasing and Risk Management 10/02/02 2 FIRM CITY OF FORT COLLINS BID PROPOSAL BID NO. 5743 BID DATE: October 23, 2002 WE HEREBY ENTER OUR BID FOR THE CITY OF FORT COLLINS' REQUIREMENTS FOR Conduit, PVC 4" PER THE BID INVITATION AND ANY REFERENCED SPECIFICATIONS. QUANTITY: DESCRIPTION: 328,320 Ea. Conduit, PVC, 4" x 20' overall length, 4.0" min. depth belled end, .154" wall thickness, per Spec. 366- 200, Serial 04, Rev. G. As per eleven (1 1) pages of specifications attached. $ Ea. $ Total Mfr. Mfr. # "Delivery to be taken as follows: 54,720 FT the first of each of the following months: December 2002 February 2003 April 2003 May 2003 June 2003 August 2003 "We retain the option of revising the above schedule one month before the next scheduled shipment. Deliveries will meet the above delivery dates. Yes No Items being bid meet the above specifications without exception. Yes_ No If no, please list exceptions, specifying paragraph reference number, on a separate sheet and attach to your bid. For purposes of warranty and service ONLY approved manufacturers or distributors authorized by an approved manufacturer to serve the Fort Collins area may bid. 10/02/02 3 Bid #5743 SUPPLEMENTAL INSTRUCTIONS Prices quoted must remain firm for a 30 day period after the opening date. Freight terms: F.O.B. destination freight prepaid. All freight charges must be included in pricing submitted on proposal and not entered as separate pricing. Any discount allowed by Vendor for prompt payment, etc. must be reflected in quoted figure, and not entered as separate pricing. The City reserves the right to accept or reject any and all quotes. Bidder not responding to the services requested in this bid shall be removed from our automated listing for: Not Applicable Any questions or inquiries regarding this bid should be directed to: Opal F. Dick, CPPO, Senior Buyer (970) 221-6778 SIGNATURE AND TITLE TYPED OR PRINTED NAME AND TITLE COMPANY NAME (AREA CODE) TELEPHONE NUMBER/FAX NUMBER ADDRESS: STREET, CITY, STATE, ZIP DATE 10/02/02 4 SPECIFICATION FOR PLASTIC CONDUIT FOR UNDERGROUND INSTALLATION Specification No.: 366-200 Rev. G May, 1999 REV. SYM: G THE CITY OF FORT COLLINS Light and Power Department P.O. Box 580 Fort Collins, CO 80522 SPECIFICATION NO: 366-200 TITLE: PLASTIC CONDUIT FOR UNDERGROUND INSTALLATION APPROVED BY: Gam/ T ii M. Sagen Chief Design Engineer Originated: 3/20/37 REVISED: 5/5/99 ITEMS COVERED BY THIS SPECIFICATION DESCRIPTION ASTM REFERENCE SERIAL STORE'S NO. 2" P.V.C. Conduit DB 120 02 6535-1081 4" P.V.C. Conduit DB 120 04 6541-1120 5" P.V.C. Conduit EB 35 05 6543-1142 1 366-200 REV. SYM: G PREVIOUS REVISION DESCRIPTIONS ON FILE REVISION DESCRIPTION CHANGE NOTICE APPROVED REVISION D: ADD APPENDIX A, Approved N/A S. Coram Manufacturers Tim Sagen 3-12-92 REVISION E: Update Appendix A, Remove N/A Tim M. Sagen Condux S.Coram 3-10-94 REVISION F: Update Appendix A, Change Manufacturer O. Dick (Quail Plastics to NAPCO) Tim Sagen 3/4/97 REVISION G: Change 4" conduit to DB 120, wall thickness .154 N/A F S_yG-99 i 2 366-200 REV. SYM: G LIST OF ACTIVE PAGES ORIGINAL PAGES ADDED PAGES SHEET NO. REV. SYM: SHEET NO, REV. SYM: SHEET NO. REV. SYM: 1 G 2 G G 4 D 5 C 6 C 7 G 8 C 9 C 10 F 3 366-200 TABLE OF CONTENTS REV. SYM: D PAGE TitlePage............................................................................................................................... I RevisionRecord...................................................................................................................... 2 Listof Active Pages................................................................................................................ 3 Tableof Contents.................................................................................................................... 4 1.0 Scope.......................................................................................................................................5 2.0 Applicable Documents............................................................................................................ 5 3.0 Requirements .................. ..................................... ................................. ........._...................... 5 3.1 General Requirements for Design............................................................................... _......... 5 3.2 Specific Requirements for Design. .......... .........................._..............................._ .. .. ....... 7 4.0 Quality .Assurance.. ... .._..................... .......... ................... ........_.............................................. 8 4.1 Responsibility for Inspection ._ ... ................................ ........ ......._................ ........................_. 8 4.2 Requirements and Test Methods .......... .............................. ........ .......... ...._.......___ . 8 5.0 Preparation for Delivery... .... ,.... ._..... .,.................... ........:....................................__.............. 9 AppendixA ....................... ............ ........ ..................... .... ..................................._ _... ...__. 10 4 366-200