Loading...
HomeMy WebLinkAbout110986 FORT COLLINS WINLECTRIC - PURCHASE ORDER - 2204037^Fort City of Fort Collins Page Number: 1 of 1 Date: 06/14/02 PURCHASE ORDER NUMBER: 2204037 Delivery Date: 07/01/02 Buyer: DICK,OPAL Purchase Order number must appear on invoices, packing lists, labels, bills of lading and all correspondence NOTE: PER SPEC 366-200 Line: Qty: Units: Description: Unit Price: Extended Price: i 52800 FT 6543-1142 .9500 50,160.00 5" X 20' PVC CONDUIT 65431142 YARD CONDUIT, PVC, 5" X 20' OVERALL LENGTH, 5.0" MIN. DEPTH BELLED END, .126" WALL THICKNESS, PER SPEC. 366-200, SERIAL 05, REV. G. MFR-NAPCO SHIPMENT - WEEK OF JUNE 24 BID R6715 ph Total: 50,160.00 City of Fo C Ilins Director of Purchasing and Risk Management Mail Invoices in duplicate to: This order ilenot valid over $2000 unless signed by James B. O'Neill II, CPPO City of Fort Collins Accounting Department PO Box 580 City of Fort Collins Purchasing, PO Box 580, Fort Collins, CO 80522-0580 Fort Collins, CO 80522-0680 Phone: 970-221-6775 Fax: 970-221-6707 Email: info@ci.fort-collins.co.us Can -Tex Industries c/o Progress & Associates 2460 S. Tejon Denver, CO 80110 Certainteed Corp. P.O. Box 860 Valley Forge, PN 19482 Attn: Ann Bales Pipe -USA 4876 Leaf Court Denver, CO 80216 Attn: Art Schellinger SUGGESTED VENDORS Spec. #366-200 APPROVED BY: DA Tim CITY OF FORT COLLINS Light and Power Department P.O. Box 580 Fort Collins, CO 80522 SPECIFICATION NO: 366-200 PLASTIC CONDUIT FOR UNDERGROUND INSTALLATION APPROVED BY: Tim M. Sagen Standards Engineering Manager DATE: 3/20/87 REVISED: 5/5/99 ITEMS COVERED BY THIS SPECIFICATION DESCRIPTION ASTM REFERENCE SERIAL STORE'S NO. 2" P.V.C. Conduit DB 120 02 6535-1081 4" P.V.C. Conduit DB 120 04 6541-1120 5" P.V.C. Conduit EB 35 05 6543-1142 REVISION DESCRIPTION REVISION D: Add Appendix A, Approved Manufacturers A, Remove upaare Appendix A, Change Manufacturer (Quail Plastics to NAPCO Change 4" conduit to DB 120, wall thickness 0.154 CHANGE NOTICE N/A ---- N/A ---- APPROVED S. Coram Tim Sagen 3-12-92 S. Coram Tim Sagen 3-10-94 O. Dick Tim Sagen Rev. Sym, G 2 366-200 Rev. Sym. G TABLE OF CONTENTS PREVIOUS REVISION DESCRIPTIONS ON FILE................................................................................2 TABLEOF CONTENTS................................................................................................. 1 SCOPE ...............................................: 2 APPLICABLE DOCUMENTS...............................................................................................................4 3 REQUIREMENTS..........................................................................................................................4 3.1 GENERAL REQUIREMENTS FOR DESIGN .................................................................................4 3.2 SPECIFIC REQUIREMENTS FOR DESIGN 4 ........................................... 4 QUALITY ASSURANCE......................................................................................................................6 4.1 RESPONSIBILITY FOR INSPECTION ............... 4.2 REQUIREMENTS AND TEST METHODS....................................................................................6 5 PREPARATION FOR DELIVERY ................................................ APPENDIX A - APPROVED MANUFACTURERS..................................................................................8 3 366-200 SPECIFICATION FOR PLASTIC CONDUIT SPEC. #366-200 1 SCOPE Rev. Sym. G This Specification establishes the minimum requirements for 2", 4", and 5" plastic conduit to be used with electric Power conductors and cables for aboveground use indoors or outdoors exposed to weather and sunlight at 5,000 feet altitude, and for underground use by direct burial or encasement in concrete. 2 APPLICABLE DOCUMENTS This Specification is in accordance with the requirements of ASTM F512, titled "Standard Specification for Smoothwall Poly(vinyi Chloride) (PVC) Conduit and Fittings for Underground Installation", with exceptions as noted in the following paragraphs. 3 REQUIREMENTS 3.1 GENERAL REQUIREMENTS FOR DESIGN All conduit furnished under this Specification shall, unless otherwise specified, comply with ASTM F512. In case of conflict, the requirements of the following documents shall apply in the priority shown: This Specification. ASTM F512. Other referenced standards. 3.1.1 MATERIAL Conduit furnished under this Specification shall be made of virgin polyvinyl -chloride (PVC) compound conforming to ASTM D1784 with the minimum cell classification shown in Table I of this Specification. Chemical resistance shall be in accordance with ASTM D1784, suffix A or B. ASTM D1784 Minimum ASTM Designation Property and Value A eST D178 Order No. Unit stA Classsif tonlCell 1 Base resin Poly (vinyl Method NA Limit No. homo of mer chloride 1 Impact strength 2 (Izod)min ft-Ib/in. of 0.65 D256 2 notch Tensile strength, min 3 si 5,000 D638 2 Modulus of elasticity 4 intension, min si 500,000 D638 >6 Deflection Tempera- 158 D648 4 5 ture under load, min 4 366-200 Rev. Sym. G 3.1.2 COMPOUND Virgin compound is defined as compound, which has not previously been used to make another Product. Reworked material is defined as clean reground or repel letized materials generated from a manufacturer's own conduit extrusion, and used by the same manufacturer who generates it. Clean is considered to exclude anything foreign to the specific compound designated by the manufacturer for use under this Specification. Rework material may be used provided that the conduit or fittings produced meet all of the requirements of this Specification. 3.1.3 CONDUIT TYPE Conduit type shall be as specified in Specific Requirements for Design. 3.1.4 WORKMANSHIP The conduit shall be homogeneous throughout and free from visible cracks, holes, foreign inclusions, or other injurious defects. The conduit bore shall be smooth and free from blisters, nicks or other imperfections which could mar conductors or cables. 3.1.5 SUNLIGHT RESISTANCE/COLOR The conduit shall contain titanium dioxide pigment to produce a white color with a reflective factor of greater than eighty percent to allow outdoor storage and/or installation at 5,000 feet altitude for an indefinite period without deterioration. 3.1.6 LENGTH Conduit shall be in lengths of twenty feet overall including integral bell. Tolerance of length shall be t one inch (t 25 mm). 3.2 SPECIFIC REQUIREMENTS FOR DESIGN 3.2.1 CONDUIT DIMENSIONS AND TOLERANCES Dimensions, tolerances and pipe stiffness shall be in accordance with Table 11 of this Specification. Wall thicknesses shown in Table II are based on a minimum modulus of 500,000 psi. 5 366-200 Rev. Sym. G 3.2.2 BELLED ENDS Each length of conduit shall have an integral belled end. Glued couplings are specifically prohibited. Belled end dimensions shall be based on the clearance fit system defined in Table 2 of ASTM F512 except socket depth and out -of -round requirements shall be in accordance with Table III of this Specification. Belled ends shall be centered on the longitudinal axis to provide a visible shoulder around the entire circumference of the conduit. Both ends of each length of the conduit shall be perpendicular to the longitudinal axis of the conduit, i.e., both ends shall be square cut. cminal I Socket Entrance I Socket Bottom Socket Depth Out-of-Rour Size Inside Dia. Inside Dia, 1Ct1P.G Innhoc ._ Inches I Tolerance. 4 QUALITY ASSURANCE 4.1 RESPONSIBILITY FOR INSPECTION Unless otherwise specified, the vendor is responsible for the performance of all tests and inspection requirements specified herein. Except as otherwise specified, the vendor may utilize his own facilities or any commercial laboratory acceptable to the City of Fort Collins. The City reserves the right to perform or witness any of the tests and inspections set forth in this Specification, where such inspections are deemed necessary. If the City, upon receipt of the conduit, deems it necessary to have an independent laboratory perform tests and inspections set forth in this Specification, the manufacturer shall be responsible for all fees incurred in testing if any requirement of the specifications is not met and/or test results for that lot or shipment are not consistent with the manufacturer's certified test results. 4.2 REQUIREMENTS AND TEST METHODS 4.2.1 COMPOUND TESTS All the tests required by ASTM D1784, except the chemical resistance test, shall be made on a compound sample from each new lot or batch. The average value for all the tests made on each batch or lot shall comply with the requirements of paragraph 3,1.1 of this Specification and shall be reported in the certified test report. The chemical resistance test shall be performed annually or when compound suppliers are changed and test results shall be included in the certified test report. 4.2.2 SUNLIGHT RESISTANCE TESTS Evidence that the compound being used has been qualified in accordance with all tests required by Paragraph 17 of UL 651 shall be included in the certified test report. 4.2.3 PERFORMANCE TESTS Conduit furnished under this Specification shall pass all tests required by and performed in accordance with ASTM F512 except 2-inch conduit shall have a minimum impact resistance of 40-foot-pounds at 32°F (0°C). 6 366-200 Rev. Sym. G 4.2.4 EXTRUSION QUALITY TEST The extrusion quality shall be determined by immersion in anhydrous acetone in accordance with ASTM D2152. Finished duct shall not flake or disintegrate when subjected to this test. 4.2.5 CERTIFICATION The manufacturer shall furnish to the purchaser certified copies of the results of the tests on each lot or shipment and size of conduit ordered, prior to payment. The certified test report shall state the lot or control number and manufacturer of compound used and shall give specific test values for compound tests, stiffness test, and tests having other than a simple Pass/Fail result. Any conduit tested by the City that does not yield results consistent with the certified test reports for that lot or shipment will be sufficient reason for rejection of the entire lot or shipment. City of Fort Collins purchase order number shall be noted on the first page of each report. Copies shall be sent to the Design section of Fort Collins Light & Power. Unsigned copies are not acceptable even if accompanied by a signed cover letter. 5 PREPARATION FOR DELIVERY Conduit shall be bundled by individual size into units suitable for shipping and stacked storage To protect the bells from deformation caused by pressure from adjacent conduits, each bundle shall be assembled such that bells are all at the same end of the bundle with the bell ends of alternating layers recessed at least the full length of the bells in adjacent layers. The bundles shall be secured using two steel bands with 2" x 4" minimum wooden boards under the bands, sets of bands and boards to be spaced appropriately along the length of the bundle forming adequate crate frames to provide the vertical stacking, frame to frame, to minimize stacked storage deformation with the stack height up to ten feet. Direct contact between the steel bands and the conduit anywhere on the perimeter of the bundle is expressly prohibited. Bundles shall be shipped on an open bed truck. 7 366-200 Rev. Sym. G APPENDIX A Conduit purchased under this Specification shall be of the manufacturers shown below. Manufacturers not listed below may submit written proposals demonstrating compliance with these Specifications for consideration of addition to the accepted manufacturers list prior to the next request for bids. In addition to inclusion on the list below, manufacturer's conduit must also satisfy all requirements of this Specification to be acceptable. MANUFACTURER Can -Tex Certainteed North American Pipe Corporation (NAPCO) 8 366-200