HomeMy WebLinkAboutRESPONSE - BID - 5452 MAPO TRAFFIC SIGN POSTSSIGNATURE PAGE
The undersigned Bidder, having examined these documents, and having full knowledge of the condition under
which the work described herein must be performed, hereby proposes that he will fulfill the obligations
contained herein in accordance with all terms, conditions, and specifications set forth, and that he will furnish
all required products and pay all incidental costs in strict conformity with these documents, for the stated prices
as payment in full
Submitting Finn
Address — y9__. C Vtq T! / \ V
C;
0
Telephone Number 3o 3 - ag to - 7 o s I _
Name of Agent (printttype)
Title
Autho
Date
Attest tAXAY Au ) 11_1 X )I
My Commission Expires
CORPORATE: SEAL
N.XOTA�
COO
oPP
cod
ADDENDA FORM
My Commission Expires lZ23P2003
tThe,undersrgned�hereby.;acknowledges receipt of the following applicable addenda
Addenda Number Date
f8
' vul
ESTIMATED QUANTITIES
EST QTY UNIT
PRICE
SECTION 1 -SIGN POSTS
1. TEL-SPAR 12 gauge
/V6 Z /,D
1" Perf Sq Post 10' length
50
$
1 1/2' Perf Sq Post, 10' length
100
$
$ �07
1 3/4" Perf Sq Post, 8' length
300
I�
1 3/4" Perf Sq Post, 10' length
3550
$�%
1 3/4" Perf Sq Post, 11' length
1000
$ 02 �I'7o
70
1 3/4" Perf Sq Post, 12' length
200
$ c2
2" Perf Sq Post, 10' length
750
$
2" Perf Sq Post, 11' length
100
$
Sq Pos1, 12' length
1000
O
$
2" Perf
2 TEL-SPAR 14 gauge
2" Perf Sq Anchors, 3' length base
1200
$ S_
e�llff 6f
1 3/4" Perf Sq Post, 10' length
200
s 14,
!`
1 3/4" Perf Sq Post, 12' length
500
$�_
3. TEL-SPAR'12 gauge
1 1/2" by 1 1/2" Anchors, 1 1/2' length
200
$ 0` _
�i
$
1 1/2" Perf Sq Post, 3' length
750
1 3/4" Perf Sq Post 2' length 100
0
2" Perf Sq Anchors, 3' length base
5230
$?,
a�
21/4" Perf Sq Anchors, 3' length base
1400
$�_
FIRM NAME S= S�v eET16� yd&DVC4�
SECTION 2 -DELINEATOR POSTS
TOTAL
16
1- 6' u Channel Delineator Posts
min 1 121bs per foot 800
2 6' U-Channel Posts, min 31bs per foot 800
3 11' U-Channel Posts, min 21bs per foot 400
SECTION 3 - MISCELLANEOUS
1 FO 175-VS2 V-LOCKS 24" X 1 3/4" 475
Includes wedges
GRAND TOTAL
DO
$ a1 `i,3 D.
17
H1/04/HH 15:10:07 City of FO&
Collins-> 3034671302 D303 T&ITAX Page 016
1. SECTION 1 SIGN POSTS
Material
Steel posts furnished shall conform to the Standard Specifications for Hot rolled Carbon Steel, commercial
quality ASTM Designation A-569-72
Finish
Material shall i be hot dipped galvanized coating conforming to ASTM A525, Des G-90 Zinc coating to
form an excellent bond with the steel surface so as not to be affected by subsequent forming operations
Corner weld shall be zinc coated after scarfing operation Exposed edges to be protected against
corrosion by "sacrificial action" when zinc is present on intimate adjacent areas
Shape
The cross section of the post shall be square tubing formed of 12 gauge ( 105 USS gauge) steel, carefully
formed into six and, if necessary, shall be welded in such a manner that weld or flash shall not interfere
with telescoping
Holes
Hole diameter shall be seven -sixteenth (7/16") plus or minus one sixty-fourth ('1/64") inch on 1" centers, on
all four sides, for the entire length of the post Holes shall be on the center line of each side true alignment,
and opposite to each other
Length
The length of each post shall be as specified, and have a permissible length tolerance of plus or minus
one -quarter (114) inch Cuts through holes will not be accepted
Telescoping Properties
The finished posts shall be straight and shall have a smooth, uniform finish It shall be possible to
telescope all consecutive sizes of square tubes freely and for not less than ten feet or their length without
the necessity, of matching any particular face to any other face All holes and ends shall be free from burrs,
and ends shall be cut square
Delivery Requirements
Delivery of these materials must be made in a flat-bed trailer for fork lift unloading, otherwise the order shall
be refused, unless transporter agrees to unload on -site Twenty-four (24) hour notice must be given prior
to delivery
Specifications
The specifications shall be considered a minimum specification
2. SECTION 2 U-CHANNEL DELINEATOR POSTS
A Must have baked green enamel finish The post must have centered 3/8"' holes on 1 "centers the
entire length with the length and pounds per linear foot as specified on bid schedule, Section VIII
FIRM NAME: ��avut��a' S e S r� 5,
15