HomeMy WebLinkAboutBID - 5406 LP TRANSFORMERS 150 300KVAAdmix. strative Services Purchasing Division City of Fort Collins INVITATION TO BID Sealed bids will be received and publicly opened at the office of The Director of Purchasing and Risk Management, 256 West Mountain Avenue, Fort Collins, Colorado 80521, ( P O Box 580, 80522) at the time and date noted on the bid proposal and/or contract documents Bids must be received at the Office of the Director prior to the opening time (our clock) SPECIAL INSTRUCTIONS All bids must be signed by an authorized representative of the company with the legal capacity to bind the company to the agreement Bids may be withdrawn up to the date and hour set for opening Once bids have been accepted by the City and opening time has passed, failure to enter into contract or honor the purchase order will be cause for removal of supplier's name from the city of Fort Collins' bidders list for a period of twelve months from the date of the opening. The City may also pursue any remedies available at law or in equity Bid prices must be held firm for a period of forty-five days after bid openings Submission of a bid is deemed as acceptance of all terms, conditions and specifications contained in the City's specifications initially provided to the bidder Any proposed modification must be accepted in writing by the City prior to award of the bid Only bids properly received by the Purchasing Department will be accepted No proposal will be accepted from, or any purchase order awarded, to any person, firm or corporation in default on any obligation to the City All bids must be labeled with both the project name and bid number indicated on the bid proposal Bids must be furnished exclusive of any federal excise tax, wherever applicable Bidders must be properly licensed and secure necessary permits wherever applicable Vendors not responding to requests for bid shall be removed from our automated listing for the requested commodities/services The City may elect where applicable, to award bids on an individual item/group basis or on a total bid basis, whichever is most beneficial to the City The City reserves the right to accept or reject any and all bids, and to waive any irregularities or informalities Sales Prohibited/Conflict of Interest No officer, employee, or member of City Council, shall have a financial interest in the sale to the City of any real or personal property, equipment, material, supplies or services where such officer or employee exercises directly or indirectly any decision -making authority concerning such sale or any supervisory authority over the services to be rendered This rule also applies to subcontracts with the City Soliciting or accepting any gift, gratuity favor, entertainment, kickback or any items of monetary value from any person who has or is seeking to do business with the City of Fort Collins is prohibited 256 W Mountain Avenue • PO Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6775 • FAX (970) 221-6707 TABLE OF CONTENTS REV. SYM CC PAGE Title Page 1 Items Covered by this Specification. 2 Revision Record 3 List of Active Pages. 4 Table of Contents 5 1 0 Scope 6 2 0 Applicable Documents . . . .. . . 6 3.0 Requirements.. .1..... . .. . ... ..... . 7 3 1 General Requirements for Design ................ 7 3 2 Specific Requirements for Design of 368-300-015 9 3 3 Specific Requirements for Design of 368-300-016 20 3 4 Specific Requirements for Design of 368-300-030 20 3 5 Specific Requirements for Design of 368-300-031 20 3 6 Specific Requirements for Design of 368-300-050 20 3 7 Specific Requirements for Design of 368-300-051 21 3 8 Specific Requirements for Design of 368-300-076 21 3 9 Specific Requirements for Design of 368-300-101 22 3 10 Specific Requirements for Design of 368-300-151 22 3 11 Specific Requirements for Design of 368-300-201 23 3 12 Specific Requirements for Design of 368-300-251 23 3 13 Specific Requirements for Design of 368-300-006 24 3.14 Specific Requirements for Design of 368-300-075 25 3 15 Specific Requirements for Design of 368-300-100 25 3 16 Specific Requirements for Design of 368-300-008 26 3 17 Specific Requirements for Design of 368-300-007 26 3 18 Specific Requirements for Design of 368-300-009 27 4 0 Quality Assurance 27 4 1 General Q C 27 4 2 Test Conditions 27 4 3 Not Used 28 4 4 Functional Tests 28 4.5 Not Used 28 4 6 Test Methods - Functional Tests 28 5 0 Preparation for Delivery 29 6 0 Definitions 30 Appendix A 31 Appendix B 35 Appendix C 36 5 368-300 GIBS W41 REV SYM: CC SPECIFICATION FOR PAD -MOUNTED COMPARTMENTAL -TYPE, THREE-PHASE DISTRIBUTION TRANSFORMERS WITH SEPARABLE INSULATED LOAD BREAK HIGH -VOLTAGE CONNECTORS 1.0 SCOPE 1 1 This Specification establishes the minimum electrical requirements and mechanical features of three phase, 60 HZ, mineral oil immersed, self -cooled, pad -mounted, compartmental -type distribution transformers rated 2500 kVA and smaller, high voltage 13,200 Grd Y/7620 volts, with separable insulated load break high voltage connectors These transformers are used for step down purposes from an underground primary cable supply 1.2 This standard generally conforms with ANSI requirements for pad - mounted compartmental -type, self -cooled, three-phase, distribution transformers for use with separable insulated high -voltage connectors, C57.12 26 2 0 APPLICABLE DOCUMENTS The following documents form a part of this Specification to the extent specified herein The latest issue in effect on the date of invitation for bids shall form a part of this Specification, unless otherwise noted. 2 1 ANSI C57.12.00 Distribution, power, and regulating transformers, and shunt reactors, general requirements for 2.2 ANSI C57.12.26 Pad mounted, compartmental -type, self -cooled three phase, distribution transformers for use with separable insulated high voltage connectors, high voltage 34,500 Grd Y/19,920 volts and below, 2500 kVA and smaller, requirements for 2.3 ANSI C57.12.70 Terminal markings and connections for distribution and power transformers. 2 4 ANSI C57.12.80 Terminology for power and distribution transformers 2 5 ANSI C57.12.90 Distribution, power, and regulating transformers, and shunt reactors, test code for 6 368-300 REV SYM• CC 2 6 ANSI/IEEE 386 Separable insulated connectors for power distribution systems above 600V 2 7 NEMA STANDARD TR1 Transformers, regulators and reactors 3.0 REQUIREMENTS 3.1 GENERAL REQUIREMENTS FOR DESIGN 3.1 1 BASIC DESIGN STANDARDS Transformers purchased under these Specifications shall be new and, unless otherwise specified, meet the requirements of the applicable ANSI Standards and the modifications and additions given in the subsequent paragraphs In case of conflict, the requirements of the following documents shall apply in the priority shown: a) This Specification b) ANSI C57 12.26 c) Other applicable ANSI and NEMA Standards 3 1 2 KILOVOLT -AMPERE TEMPERATURE RATINGS Kilovolt -ampere ratings are continuous and are based on not exceeding either a 65°C average winding temperature or an 800C hot spot temperature rise The temperature rise of the insulating oil shall not exceed 650C when measured near the top of the tank The temperature rise is based on an altitude of 3,300 feet 3 1 3 GENERAL CONSTRUCTION 3.1 3.1 The pad -mounted compartmental -type transformers shall consist of the transformer tank, high -voltage cable terminating compartment, and the low -voltage cable terminating compartment. All three of these components shall be assembled as an integral unit, tamperproof and weatherproof for mounting on a pad. There shall be no exposed screws, bolts or other fastening devices which are externally removable, except the main cover bolts may be exposed Where the main cover bolts are exposed, the corner bolts shall be welded or otherwise rendered tamperproof There shall be no opening through which foreign objects such as sticks, rods, or wires might be inserted to contact live parts Suitable means for padlocking the compartment door(s) shall be provided 3 1 3 2 The high and low -voltage compartment shall be located side by side on one side of the transformer tank When facing the compartment, the low -voltage compartment shall be on the right. 7 368-300 REV. SYM. CC 3 1 3 3 Construction of the unit shall be such that it can be lifted, skidded, and slid into place on the mounting pad without disturbing the entrance cables 3 1 3 4 An undercoating over the regular finish or an equivalent treatment shall be applied to all surfaces that are in contact with the pad to minimize corrosion 3 1.3 5 Minimum dimensions shall be as shown in Fig 1 or Fig 2 of this Specification Maximum transformer and minimum pad dimensions are shown in Fig 6 of this Specification 3.1 4 LOSSES The total losses of a transformer shall be the sum of the excitation losses and the load losses (I'R losses) Load loss tests shall be performed and reported on all units regardless of whether or not a record of such tests is available on duplicate units Loss evaluations and loss costs will be based on the values shown in the "Special Conditions and Supplemental Instructions to Bidders." Transformers will be evaluated on excitation losses and I'R losses at the specified rates If tested losses exceed quoted losses but are within the tolerances of Table 18, ANSI C57 12 00-1987, the additional cost incurred from the differential of losses will be calculated using the following equation and the above specified rates and will be deducted from the original Purchase Order or back charged to the manufacturer In Table 18 and the following equation "Units" shall mean "Transformers of the same size and desiq_n on one order " Excess loss $ _ [No of units] [(No Load Loss Evaluation $) (Avg No Load Losses Quoted No Load Losses) + (Load Loss Evaluation $) (Avg Load Losses - Quoted Load Losses)]. If this equation results in a negative number no credit will be given the Supplier If any unit or units exceed the tolerances of Table 18, ANSI C57.12.00-1987, that unit or units shall not be shipped without express permission from the City. If accepted, the deduction for excess losses will be based on the following equation Excess loss $ = (No Load Loss Evaluation $) (No Load Losses - Quoted No Load Losses) But Not Less Than Zero + (Load Loss Evaluation $) (Load Losses - Quoted Losses) But Not Less Than Zero 3 1 5 SERVICE CONDITIONS Service conditions shall be as defined in paragraph 4 1 of ANSI C57 12 00 except the ambient temperature range shall be 400C above to 32°C below zero The transformer shall operate safely with starting temperatures as low as 32°C below zero 8 368-300 REV. SYM: EE 3.2 SPECIFIC REQUIREMENTS FOR DESIGN OF 368-300-015 3.2.1 FUNCTIONAL DESCRIPTION The transformer shall be a three phase, pad mounted, loop feed -safe break, "deadfront" type for use on a 13.8 kV grounded "Y" distribution system. 3.2.2 DESIGN AND CONSTRUCTION 3.2.2.1 RATING The transformer shall be rated as follows: a) kVA Capacity b) High Voltage c) Low Voltage d) Taps e) Impedance f) Angular displacement 3 2 2.2 INSULATION LEVEL 150 13,200 Grd. Y/7620 (neutral commonly grounded with secondary neutral) 208Y/120 Two - 2Yz% FC above and below normal. 2.1% Fig 10 ANSI C57 12.26-1987 3.2.2 2.1 The basic impulse insulation level (BIL) of the completely assembled transformer, including high -voltage and low -voltage terminals shall be 95 kV and 30 kV respectively. 3.2.2 2.2 Dielectric test levels shall be in accordance with the distribution levels in Paragraph 5 10 of ANSI C57.12.00-1987. 3.2.2 2.3 The unit shall withstand test voltages in accordance with ANSI Standard C57.12 00 and impulse tests in accordance with NEMA Standards for Transformers, Publication No. TR1. 3.2.2 3 TRANSFORMER CORE A five -legged core -coil assembly or three separate core -coil assemblies shall be employed. The use of three-legged designs is expressly prohibited. 3.2.2.4 HIGH VOLTAGE TAPS A no-load tap changer with external operating handle shall provide two 21/2% full capacity taps above and below normal. The operating handle shall be mounted in the primary compartment 9 368-300 REV SYM• CC 3 2 2 5 BUSHING WELLS AND TERMINALS 3.2 2 5.1 The number, location, and arrangement of bushing wells, terminals and parking stands shall be as shown in Fig. 1 or Fig 2 and Fig. 5 All low -voltage bushings and high -voltage wells shall be externally clamped and shall have leads of sufficient length to allow them to be changed without removing the cover Welded bushings and wells are expressly prohibited. 3 2 2.5 2 High -voltage bushing wells shall be 200A loadbreak interface 8.3/14 4 kV bushings in accordance with ANSI/IEEE Std 386. 3 2 2.5 3 Low -voltage line and neutral terminals shall be stud type bushings in accordance with ANSI C57 12 26-1987, Fig 9(d), shall include a separate spade with NEMA standard drilling and shall be in accordance with Fig 3 of this Specification Bushing arrangement and spacing shall be "staggered", as shown in Fig 5 of this Specification 3.2.2 5 4 The low -voltage neutral shall be a fully insulated bushing. A ground pad shall be provided on the outer surface of the tank and a removable copper ground strap shall be provided and connected between the low -voltage neutral bushing and the ground pad 3 2 2 5 5 The high -voltage neutral shall be connected to the low -voltage neutral internally with provision for opening this connection for testing 3 2 2 6 ACCLSSORY CABINET 3 2 2 6 1 The accessory cabinet shall consist of a high -voltage and low - voltage compartment generally constructed in accordance with applicable ANSI specifications and dimensioned in accordance with Fig I or Fig 2 of this Specification 3 2 2 6 2 Cabinet doors shall be hinged, removable, and lockable Stainless hinge pins shall be provided 3 2 2 7 ACCESSORY EQUIPMENT Accessory equipment shall be provided in accordance with Table I and the following details 3.2 2.7 1 Suitable jack bosses or equivalent jacking facilities shall be provided on the tank Vertical clearance for a jack shall be 111= inches minimum, 3'/2 inches maximum 3 2 2 7 2 The transformer base shall be arranged for rolling in two directions Parallel to and at right angles to the center line of the high - voltage bushings 10 368-300 REV. SYM. CC 3 2 2 7.3 Four lifting lugs shall be provided. These lugs shall be adequate strength and size and arranged on the tank to provide a suitable lift for the completely assembled unit 3 2.2 7 4 The base of the assembly shall be provided with suitable means for mounting the unit on the pad An internal flange shall be provided at the base of the accessory compartment to provide means for mounting the unit on the pad (Fig 1 and 2). 3 2 2.7 5 Terminal designations are shown in Figures 1 and 2. The identification of terminal connections shall be shown on the instruction nameplate. Instruction nameplate shall be located in the low -voltage compartment and shall be readable with cables in place Where the nameplate is mounted on a removable part, the manufacturer's name and transformer serial number shall be permanently affixed to a non -removable part Instruction nameplate shall contain the information specified in ANSI C57.12 00-1987, paragraph 5 12. In addition, either on the nameplate or label affixed near it, the manufacturer shall indicate that the dielectric fluid is non -PCB 3 2 2 7 6 An automatic pressure relief device shall be located within the compartment This device shall meet the following requirements - /4" NPT or larger male Inlet Port - Exposed parts of weather and corrosion resistant materials - Non -deteriorating gasket and o-ring material. - Manual pull ring able to withstand 25 pound force minimum - Body able to withstand 100 pound force minimum - Bug shield - Cracking pressure of 10 ± 2 psig - Resealing pressure of 6 psig minimum - Zero leak rate from resealing pressure to -8 psig - Minimum flow rate of 35 SUM at 15 psig 3 2 2 8 OIL PRESERVATION Transformers shall be of sealed -tank construction Sealed -tank construction is that which seals the interior of the tank from the atmosphere, and in which the gas plus the oil volume remains constant The transformer will remain effectively sealed for a top - oil temperature range of -320C to 105°C 3 2 2 9 TANKS The tank shall be domed or sloped to shed water and shall be of sufficient strength to support a minimum of 500 lbs Construction of the tank shall be in accordance with ANSI C57 12 26-1987, Section 7, except bolted cover is preferred. 11 368-300 REV SYM II 3 2 2 9 1 If main cover is welded, adequate handhole(s) shall be provided Handholes shall be concealed Bolted -on covers shall be adequately gasketed and tamperproof Main cover bolts may be exposed, however, where cover bolts are exposed, the corner bolts shall be welded or otherwise rendered tamperproof 3 2 2 9 2 Tank grounding provision shall be in accordance with paragraph 7 6 4 of ANSI C52 12 26-1987 3 2 2 9 3 Locking bolts shall be pentahead 3 2 2 10 OVERCURRENT PROTECTION Overcorrect protection consisting of a Cooper Power Systems ELSP oil - immersed partial range current limiting fuse in series with a Cooper Power Systems oil -immersed current sensing weak link cartridge shall be provided Fuses shall be sized to meet the following criteria • Withstand 25 times transformer rated load current for 01 second • Withstand 12 times transformer rated current for 0 1 second • Withstand 3 times transformer rated load current for 10 seconds • Allow not less than 140% nor more than 200% continuous overload • Clear fault at 3 to 4 times transformer rated current in 300 seconds 32211 COMPONENTS FOR LOOPED PRIMARY The minimum current -carrying capability of components for the looped primary cable system shall be 200 amperes (continuous) and 10,000 amperes symmetrical (momentary) 3 2 2 12 AUDIBLE SOUND LEVEL The audible sound level shall be in accordance with NEMA Standard TR1 3 2 2 13 BASE PLAN The base plan of a completely assembled unit shall be such that it can be installed on a pad of the dimensions shown in Fig 6 3 2 2 14 PAINT 3 2 2 14 1 Surfaces to be painted shall be blast cleaned (commercial blast) to provide a clean dry surface free of dirt, dust, chalk, loose paint, rust, grease and any other contaminants 3 2 2 142 EEI "Finishing Guidelines" specification shall apply Finish coat shall be Desert Tan, Munsell #10YR6 0/3 0, glossy 3 2 2 15 SAFETY LABELS The manufacturer shall NOT apply NEMA 260 Safety Labels, Purchaser will apply custom "Mr Ouch" labels after delivery 12 368-300 REV SYM II 2', 1 BELOW Q �45 MIN ON I 4 11A A 65 i_ 65 H1B I 1 L + XI X3 4 `. .. H2v B + + + H39B XO X2 B 0 I I I I 45 45 65 65 4 65 Q 380 MIN, A FLANGE 3/4' MIN 1 I/2' MAX MIN RL MIN. KVA RATINGS LOW VOLTAGE RATINGS COMPARTMENT DIMENSIONS (MINIMUM) BUSHING HEIGHT A' B 75-15O ALL 1 23 75 27 ALL 28 31 50-150-100 7000 480Y/277,208Y/I20 28 46 1500-2500 480Y1227 28 46 iw I I All tl1lllull wR III (mUun) ' IAOotCG InSInL cwp➢ nsionA -- sec 1 Ig) � V111\I1Oum (IIOILnMOIIv ~hill alloy onL inch cicaraOCL from LdLl Of pad (Ile 6) Fig 1 — Accessory Compartment and Bushing Dimensions — Configuration i 13 368-300 REV SYM: CC This configuration deleted 7/92 Fig. 2 - Accessory Compartment and Bushing Dimensions - Configuration II 14 368-306 Freight Terms Unless otherwise noted, all freight is F O B destination, freight prepaid All freight charges must be included in prices submitted on proposal Discounts Any discounts allowed for prompt payment, etc, must be reflected in bid figures and not entered as separate pricing on the proposal form Purchasing Restrictions Your authorized signature of this bid assures your firm's compliance with the City s purchasing restrictions on cement A copy of the Resolution 91-121 is available for review in the Purchasing Division or the City Clerk's office Collusive or Sham Bids Any bid deemed to be collusive or a sham bid will be rejected and reported to authorities as such Your authorized signature of this bid assures that such bid is genuine and is not a collusive or sham bid Bid Results For information regarding results for individual bids send a self-addressed, self -stamped envelope and a bid tally will be mailed to you a es B O'Neill, II, CPPO ector of Purchasing & Risk Management REV SYM CC ,6 D HOLE q PLHGES KVA 75 150 150 300 300 500 SERIAL -007 -015 -016 -030 -031 -051 -008 Fig. 3 - Four Hole "H" Spade Low Voltage Terminals 15 368-300 J- 9° i REV. SYM: CC 4 PL 4 GcS KVA 500 750 750 1000 1000 1500 2000 2500 SERIAL 050 075 076 -100 -101 -151 -201 -251 Fig. 4 - Six Hole "J" Spade Low Voltage Terminals 16 368-300 REV SYM II 4,00 A A A 4,0° 6" RADIUS MIN MIN TYPICAL 4 PLACES 1 j 3 B I I — — _— CL XO X2 KVA Low VOLTAGE RATING - e 75 - ]50 A1 4 '_ 8 225 - 500 All u P 750 - 2500 480�/277, 208Y/120 E i0 =ig 5 - Staggered low - voltage DL5"-- erra,ge n-- dimensions minimum (-,nches) NOTL ',ne snared area shown above shall ce onstroc_t v.1s ;j,h as gauges, eta 17 - 168-100 REV. SYM. CC KVA SERIAL PAD DIMENSIONS inches A B C D E F 75 -006 thru -009 75 55 40 21 15 61 150 -015 75 55 40 21 15 61 150 -016 75 55 40 21 15 61 300 -030 75 55 40 21 15 61 300 -031 75 55 40 21 15 61 500 -050 75 55 40 21 15 61 500 -051 75 55 40 21 15 61 750 -076, -075 85 72 49 23 15 67 1000 -101, -100 85 72 49 23 15 67 1500 -151 101 87 51 23 15 76 2000 -201 107 88 51 23 15 79 2500 -251 107 88 51 23 15 79 Fig. 6 - Pad Dimensions 18 368-300 REV SYM CC TABLE I ACCESSORY EQUIPMENT KVA 75-150 300 500-2500 ACCESSORY Tap changer handle in HV compartment x X x Instruction nameplate in LV compartment X X X Jacking provisions X X X Provisions for rolling in two directions X X X Lifting lugs X X X Provisions for mounting on pad X X X Arrester mounting provisions Grounding provisions in both compartments X X X Oil Drain. 1" drain plug 1" valve with sampling device X X x Upper filter press and filling plug or cap) 1" X X X Provisions for oil gauge X Provisions forpressure-vacuum gauge X X Oil gauge X Thermometer X X X Secondary CT mounting holes 4 holes on 4 3 8" x 5 5 8" centers X X X Manual/automatic pressure relief valve X X X 19 368-300 REV. SYM: EE 3 3 SPECIFIC REQUIREMENTS FOR DESIGN OF 368-300-016 The requirements for 368-300-016 transformer shall be the same as the -015 with the following exception: 3 3 1 RATING The transformer shall be rated as follows a) kVA Capacity 150 b) Low Voltage 480Y/277 c) Impedance 2.1% 3 4 SPECIFIC REQUIREMENTS FOR DESIGN OF 368-300-030 The requirements for 368-300-030 transformer shall be the same as the -015 with the following exception: 3 4 1 RATING The transformer shall be rated as follows a) kVA Capacity 300 b) Low Voltage 208Y/120 c) Impedance 2 5% 3 5 SPECIFIC REQUIREMENTS FOR DESIGN OF 368-300-031 The requirements for 368-300-031 transformers shall be the same as the -015 with the following exception 3 5 1 RATING a) kVA Capacity 300 b) Low Voltage 480Y/277 c) Impedance 2 5% 3 6 SPECIFIC REQUIREMENTS FOR DESIGN OF 368-300-050 The requirements for 368-300-050 transformers shall be the same as the -015 with the following exceptions- 3 6.1 RATING a) kVA Capacity 500 b) Low Voltage 20BY1120 c) Impedance 3 047 3 6 2 LOW VOLTAGE TERMINALS Low voltage line and neutral spades shall be in accordance with Fig. 4 20 368-306 REV. SYM: EE 3 7 SPECIFIC REQUIREMENTS FOR DESIGN OF 368-3DO-051 The requirements for 368-300-051 transformers shall be the same as the -015 with the following exceptions 3 7.1 RATING a) kVA Capacity 500 b) Low Voltage 4BOY1277 c) Impedance 3 04% 3 7 2 LOW VOLTAGE TERMINALS Low voltage line and neutral spades shall be in accordance with Fig. 3 3 8 SPECIFIC REQUIREMENTS FOR DESIGN OF 368-300-076 The requirements for 368-300-076 transformers shall be the same as the -015 with the following exceptions. 3 8 1 RATING a) kVA Capacity 750 b) Low Voltage 480Y/277 c) Impedance 5 75% 3 8 2 LOW VOLTAGE TERMINALS Low voltage line and neutral spades shall be in accordance with Fig 4 3 8 3 TANK Tank grounding provisions shall be in accordance with paragraph 7 6 4 of ANSI C57 12.26-1987 21 368-300 REV SYM• CC 3 9 SPECIFIC REQUIREMENTS FOR DESIGN OF 368-300-101 The requirements for 368-300-101 transformers shall be the same as the -015 with the following exceptions: 3 9 1 RATING a) kVA Capacity 1000 b) Low Voltage 480Y/277 c) Impedance 5 75% 3.9 2 LOW VOLTAGE TERMINALS Low voltage line and neutral spades shall be in accordance with Fig 4 3.9 3 TANK Tank grounding provisions shall be in accordance with paragraph 7 6 4 of ANSI C57 12 26-1987 3 10 SPECIFIC REQUIREMENTS FOR DESIGN OF 368-300-151 The requirements for 368-300-151 transformers shall be the same as the -015 with the following exceptions 3 10 1 RATING a) kVA Capacity 1500 b) Low Voltage 480Y/277 c) Impedance 5 75% 3.10 2 LOW VOLTAGE TERMINALS Low voltage line and neutral spades shall be in accordance with Fig 4 3 10 3 TANK Tank grounding provisions shall be in accordance with paragraph 7 6 4 of ANSI C57 12 26-1987 22 368-300 REV. SYM• CC 3 11 SPECIFIC REQUIREMENTS FOR DESIGN OF 368-300-201 The requirements for 368-300-201 transformers shall be the same as the -015 with the following exceptions 3.11.1 RATING a) kVA Capacity 2000 b) Low Voltage 480Y/277 c) Impedance 5 75% 3 11 2 LOW VOLTAGE TERMINALS Low voltage line and neutral spades shall be in accordance with Fig 4 3.11 3 TANK Tank grounding provisions shall be in accordance with paragraph 7 6.4 of ANSI C57 12 26-1987 3 12 SPECIFIC REQUIREMENTS FOR DESIGN OF 368-300-251 The requirements for 368-300-251 transformers shall be the same as the -0I5 with the following exceptions 3 12.1 RATING a) kVA Capacity 2500 b) Low Voltage 480Y/277 c) Impedance 5 75% 3 12 2 LOW VOLTAGE TERMINALS Low voltage line and neutral spades shall be in accordance with Fig 4 3 12 3 TANK Tank grounding provisions shall be in accordance with paragraph 7 6 4 of ANSI C57 12 26-1987 23 368-300 REV. SYM: EE 3.13 SPECIFIC REQUIREMENTS FOR DESIGN OF 368-300-006 The requirements for 368-300-006 transformers shall be the same as the -015 with the following exceptions. 3 13 1 FUNCTIONAL DESCRIPTION The transformer shall be a three phase, pad mounted, radial tap -safe break, "deadfront" type for use on a 13 8 kV grounded "Y" distribution system 3.13 2 RATING a) kVA Capacity 75 b) Low Voltage 208Y/120 c) Impedance 1 90% 3 13 3 BUSHING WELLS AND TERMINALS The number, location, and arrangement of bushing wells, terminals and parking stands shall be as shown in Fig 5A, 7 and 8(a) of ANSI C57 12 26-1987 except high voltage bushing wells shall be 32 to 36 inches from the base of the transformer 3 13 3 2 High voltage bushing wells shall be 200A loadbreak interface 8 3/14 4 kV in accordance with ANSI/IEEE 368 3 13 3 3 Low voltage bushings shall be staggered 3 13 4 ACCESSORY CABINET The accessory cabinet shall be dimensioned in accordance with Fig 7 of ANSI C57 12.26-1987 24 368-300 E FIRM NAME CITY OF FORT COLLINS BID PROPOSAL BID NO 5406 BID OPENING 2 00 p m lour clock) August 4, 1999 WE HEREBY ENTER OUR BID FOR THE CITY OF FORT COLLINS' REQUIREMENTS FOR TRANSFORMER, 150 KVA, 300 KVA PER THE BID INVITATION AND ANY REFERENCED SPECIFICATIONS QUANTITY DESCRIPTION 15 Ea Transformer, 150 KVA pad -mounted compartmental -type, three phase distribution with separable insulated load break high -voltage connectors High voltage rating 13200 GRDY/7620 Low voltage rating 208Y/120 Serial number 015 to be in accordance with Specification #368-300- 015, Revision II $ Ea $ Total Delivery in weeks ARO Mir & Mir # The transformers being bid meet or exceed the specifications Yes No If not, please list exceptions, (specifying paragraph reference number) on a separate sheet of paper and attach to your bid Guaranteed No Load Loss Guaranteed Full Load Loss Guaranteed Total Load Loss Impedance 1%) Escalation is , is not applicable for the transformers bid If escalation applies, the bidder shall indicate in his bid the specific items or materials subject to escalation, and shall give the method and indices to be used in computing the amount thereof Escalation occurring after the quoted delivery date will not be paid unless delays are the result of actions by the city Escalation occurring after acceptance if purchaser exercises the option to delay shipment after manufacturing is completed, will not be paid 3 REV SYM CC 3 14 SPECIFIC REQUIREMENTS FOR DESIGN OF 368-300-075 The requirements for design of 368-300-075 transformers shall be the same as the -015 with the following exceptions- 3 14.1 RATING a) kVA Capacity 750 b) Low Voltage 208Y/120 c) Impedance 5.75% 3 14.2 LOW VOLTAGE TERMINALS Low voltage line and neutral spades shall be in accordance with Fig 4 3.14.3 TANK Tank grounding provisions shall be in accordance with paragraph 7 6 4 of ANSI C57 12 26-1987. 3 15 SPECIFIC REQUIREMENTS FOR DESIGN OF 368-30-100 The requirements for 368-300-100 transformers shall be the same as the -015 with the following exceptions 3 15 1 RATING a) kVA Capacity 1000 b) Low Voltage 208Y/120 c) Impedance 5 75% 3.15.2 LOW VOLTAGE TERMINALS Low voltage line and neutral spades shall be in accordance with Fig. 4 3 15 3 TANK Tank grounding provisions shall be in accordance with paragraph 7 6 4 of ANSI C57 12 26-1987. 25 368-300 REV. SYM: EE 3 16 SPECIFIC REQUIREMENTS FOR DESIGN OF 368-300-008 The requirements for 368-300-008 transformers shall be the same as the -015 with the following exception: 3 16 1 RATING a) kVA Capacity 75 b) Low Voltage 208Y/120 c) Impedance 1.90% 3 17 SPECIFIC REQUIREMENTS FOR DESIGN OF 368-300-007 The requirements for 368-300-007 transformers shall be the same as the -015 with the following exceptions 3 17 1 FUNCTIONAL DESCRIPTION The transformer shall be a three phase, pad mounted, radial tap -safe break, "deadfront" type for use on a 13 8 kV grounded "Y" distribution system 3 17 2 RATING a) kVA Capacity 75 b) Low Voltage 480Y/277 c) Impedance I 90% 3 17 3 BUSHING WELLS AND TERMINALS 3 17 3 1 The number, location, and arrangement of bushing wells, terminals and parking stands shall be as shown in Fig. 5A, 7, and 8(a) of ANSI C57 12 26-1987, except high voltage bushings shall be 32 to 36 inches above the base of the transformer. 3.17 3 2 High voltage bushing wells shall be a 200A loadbreak interface 8 3/14 4 kV in accordance with ANSI/IEEE 386 3 17 3 3 Low voltage bushings shall be staggered 3 17 4 ACCESSORY CABINET The accessory cabinet shall be dimensioned in accordance with Fig 7 of ANSI C57 12 26-1987 26 368-300 REV. SYM: EE 3 18 SPECIFIC REQUIREMENTS FOR DESIGN OF 368-300-009 The requirements for 368-300-009 transformers shall be the same as the -015 with the following exception 3 18 1 RATING a) kVA Capacity 75 b) Low Voltage 480Y/277 c) Impedance 1 70% 4 0 QUALITY ASSURANCE 4 1 GENERAL 4 1 1 RESPONSIBILITY FOR INSPECTION Unless otherwise specified, the vendor is responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified, the vendor may utilize his own facilities or any commercial laboratory acceotable to the City of Fort Collins The City reserves the right to perform or witness any of the inspections set forth in this Specification where such inspections are deemed necessary 4 1 2 TEST REPORT The manufacturer shall furnish to the purchaser certified copies of the results of all tests prior to payment Copies shall be sent to the Design Section as well as with the invoice Unsigned copies are not acceptable even if accompanied by a signed cover letter The Quality Control Manager shall review and sign each test report 4 2 TEST CONDITIONS Unless otherwise specified, testing defined in Section 4.6 shall be conducted under the following conditions 4 2 1 REFERENCE TEMPERATURE The reference temperature to which losses, impedance, regulation, and efficiency are corrected shall be 851 C 4.2 2 TOLERANCE ON IMPEDANCE VOLTAGE Tolerance shall be as specified in ANSI C57 12 00 4 2 3 TOLERANCE ON IMPEDANCE VOLTAGE ON A TAP The percent departure of tested impedance voltage on any tap from tested impedance voltage at rated voltage shall not be greater than the total tap voltage range expressed as a percentage of the rated voltage 27 368-306 REV SYM GG 4 4 FUNCTIONAL TESTS Functional tests shall consist of those tests and related requirements as cross referenced in Table II and shall be performed on each unit except Temperature and Noise Tests which shall be performed on one unit of each design (KVA) per order 4 5 Not used TABLE II FUNCTIONAL TESTS TEST TEST PARAGRAPH REQUIREMENT REFERENCE OR Examination of Product 4 6 3 0, 3 1, 3 2, 3 10 (This Spec) Ratio 4 6 C57 12 00 Section 8 (ANSI) Polarity and Phase Relation 4 6 C57 12 00 Section 8 (ANSI) Excitation Loss 4 6 IC57 12 00 Section 8 (ANSI) Excitation Current 4 6 C57 12 00 Section 8 (ANSI) Impedance and Load Loss 4 6 C57 12 00 Section 8 (ANSI) Temperature Tests * 4 6 C57 12 00 Section 8 (ANSI) Dialectric Tests 4 6 1 3 2 2 2 (This Spec) Impulse Tests 4 6 2 3 2 2 2 (This Spec) Leak Testing 4 6 3 3 2 2 8, 3 2 2 9 (This Spec) Noise Testing * 4 6 4 3 2 2 11 (This Spec) one unit per design per order 4 6 TEST METHODS -- FUNCTIONAL TESTS Each completed unit shall be inspected to determine compliance with respect to dimensions material workmanship construction and marking, and routine tests on all units shall be made as specified in Section 8 of ANSI Standard C57 12 00 and in ANSI Standard C57 12 90 In addition to routine tests the following test requirements and/or modifications shall apply 4 6 1 DIELECTRIC TESTS Induced and applied potential Dielectric Tests shall be performed in accordance with ANSI C57 12 00 and C57 12 90 The low voltage windings shall have a test potential to ground of 10 000 volts for one minute The test potential between high voltage windings shall be 34 000 volts for one minute 28 368-300 4.6.2 4.6.3 4,6.4 Im IMPULSE TESTS ANSI Standard Impulse Tests shall be performed Test shall use a 1 5 x 50 microsecond wave LEAK TESTING 41TAS '0=1111 Full Wave Impulse The transformer tank shall be filled with oil and tested for air and oil leaks under (1) 4 psig vacuum for i hour, (2) 7 psig pressure for 24 hours in the sequence indicated An alternate method of leak testing may be performed by injecting halogen gas under 10 psig and detecting leaks through the use of a halogen detector (Note, the automatic/manual pressure relief device must be removed for this test) NOISE TESTING Noise testing shall be conducted in accordance with applicable NEMA Standards PREPARATION FOR DELIVERY Transformers shall be prefilled with the appropriate amount of transformer oil and shall be shipped by open -bed truck Units shall be packaged in such a way as to provide for ease of handling and to protect units from shipping damage Units shall be fully pallatized in four-way universal pallats with 28" minimum openings to facilitate handling from any side Pallats shall be independent of the transformer The Supplier shall give 24 hour notice prior to delivery for any shipments where an individual transformer weighs over 4,000 pounds In addition to these requirements, the Supplier shall comply with any additional requirements or modifications shown on the purchase order and/or supplemental instructions 29 368-300 F REV. SYM: CC 6 0 DEFINITIONS AND ABBREVIATIONS 6 1 Vendor or Supplier - The manufacturer and/or manufacturer's agent supplying or quoting on the specified article 6 2 Article, Unit, Assembly - All refers to the equipment defined by this Specification 6 3 DC or d.c. - Direct Current. 6.4 AC or a.c. - Alternating Current 6.5 °C - Degree Celsius (Centigrade) 6 6 °F - Degree Fahrenheit 6 7 kV - 1000 volts. 6 8 CPS or Hz - Cycles per second. 6 9 prig - Pounds per square inch gauge 6 10 V or v - Volts 6 11 kVA - 1000 Volt-amperes 30 368-300 REV. SYM: CC APPENDIX A Typical pad designs are shown in Figures IA through 3A. The dimensions in inches of Figures lA through 3A will fit the minimum compartments on transformers covered by this Specification as well as the maximum transformer envelope 31 368-306 b REV. SYM: EE L 85' 15' I PRIMARY SEC 6' FRONT _ I I T3' l FOUR R3 REBAR LENGTH AND VI➢TH 10 _ 40 3 L 7 S/8' 3 Notes on Pod Material — i Concrete must be 3,000 psi minimum 2 Maximum coarse aggregate size 1 1/2 inches Space requirements for pad and primary switching cabinet will generally be 9' X 12' Factors to be considered in locating the pad include -- I Accessibility — The transformer pad shall be accessible to line boom trucks equipped for the installation and removal of heavy transformers Such accessibility shall not require intrusion on adjacent property 2 Proximity of Buildings, Walls, Barriers, and/or Overhangs -- In addition to the clearances required for installation and removal, the minimum clearance in front of the transformer pad shall be eight (8) feet and the minimum clearance from all other sides shall be three (3) feet If the building has on overhang, clearance to the edge of the transformer pad shall be measures horizontally from the outer edge of the overhang Transformers through 300 KVA may be installed under the overhang if the vertical clearance between the pad and the overhang is at least 25 feet and the location is accessible to line boom trucks 3 Codes and Standards — In addition to the above, the installation shall conform to the National Electric Code and federal, state and city codes and standards CITY OF FORT COLLINS LIGHT AND POWER DEPARTMENT TRANSFORMER PAD DESIGN 75 - 500 KVA 3 PHASE 32 368-300 Figure 2A - Pad Design 85, I I I I I I I I I I I I I I I I I I I I I I 15' I PRIMARY SECONDARY FRONT � — T 8' — 26' — 23' —+— 18, 3 I 49 I 3, e I / Notes on Pad Material - 72 REV. SY MCC T 3' i L 3' T 3' FOUR 43 REBAR LENGTH AND V1DTH 3' 1 Concrete must be 3,000 psi minimum 2 Maximum coarse aggregate size 1 1/2 inches Space requirements for pad and primary sw,tching cabins t will generally be 9' X 12' Factors to be considered in locating the pad include - 1 Accessibility - The transformer pod shall be accessili to Une boom trucks equipped for the installation and removal of heavy transformers Such accessibility shall not require intrusion on adjacent property 2 Proximity of Budd,ngs, Walls Barriers and/or Dverhangs - In addition to the clearances required for Instottation and removal, the minimum clearance ,n front of the trans Former pod shall be eight (8) Feet and the ninimun clearance From all other sides shall be Four (4) feet If the budding has an overhang, clearance to the edge or the trans Fo,-mer pad shall he measured horizontally Rrom thr outer edge of the overhang Transformers through 300 KVA moy be installed under the overhang ,F the vertical clearance between the pad and the overhang is at least 25 Feet and the lC)CUtiOn is accessible to i,ne boom trucks 3 lodes is ad Stanoards - In addition to the above the nstalletlon shall connorm to the notional Electric Code and Federal state and city codes Ono ,tandar-ds iSF04f1 _F POD DESIGni r I11' Lj- FORT COL' INS i 500 - 1000 �v; PE�/1;10N D/�TF�� I IC, l „r'q POW''=4 Nile 2 1990 -- - - - - - ---_33- 368-300 Figure 3A - Pad Design REV SYM. CC 107' - - -1-1- - T -1-1- PRIMARY IS' vIN➢Ov SECONDARY FRONT f 28' — 23'— — 28' 28' _I �3, FIVE k5 REBAR LENGTH AND VIDTH 3' 3' 7T5/8' I Notes on Pad Mate-lal - 1 Concrete must be 3,000 psi minimum 2 Maximum coarse aggregate size 1 1/2 Inches Space requirements for pod and primary switching cabinet �,U generally be 9' X 12' Factors to be considered in locating the pad include - 1 Accesslol6ty - The transformer pad shall be accessible to line boom trucks equipped For the installation and removal of heavy transformers Such access�b,hty shall not require intrusion on adjacent property 2 Proximity of Buildings, Walls, Barriers and/or Overhangs In addition to the clearances requred For installation and removal, the minrmum clearance is front of the transformer pad shall be eight (8) feet and the minl�ur^ clearance From all other side shall be four (4) Feet If the hjiidmq has an overhang, clearance to the edge of the trans Former pad shall be measured horizontally from the outer edge of the overhang Transformers through 300 KVA ma, oe installed under the overhang IF the vertical clearance het -en the pad an,) the overhang Is at least 25 feet and trim locatior IS occessible to line boom trucps 3 Codes ano Standards - In aooltion to :he -hovo the vrstaUa tlon shui' Conform Ao ',, I,,twnal f_'c C'r-i� Codc and federal Stotc 0n3 C,"� Codes nrn Sto�dards - --- - — — - — TR„r.'�_J " CI1', Ur FOR i ('DI r IIdS i .g^ . yr-, 12r • i I ��l i r.iJD P01✓� � 000 34 368-300 Firm Na QUANTITY DESCRIPTION 4 Ea Transformer, 300 KVA pad -mounted compartmental -type three phase distribution with separable insulated load break high -voltage connectors High voltage rating 13200 GRDY/7620 Low voltage rating 208Y/120 Serial number 030 to be in accordance with Specification #368-300-030, Revision II $ Ea $ Total Delivery in weeks ARO Mfr & Mfr # Guaranteed No Load loss Guaranteed Full Load Loss Guaranteed Total Load Loss Impedance I%) Yes _ No _ If not, please list exceptions (specifying paragraph reference number) on a separate sheet of paper The transformers being bid meet or exceed the attached specifications and attach to your bid documents Escalation is , is not applicable for the transformers bid If escalation applies, the bidder shall indicate in his bid the specific items or materials subject to escalation, and shall give the method and indices to be used in computing the amount thereof Escalation occurring after the quoted delivery date will not be paid unless delays are the result of actions by the city Escalation occurring after acceptance if purchaser exercises the option to delay shipment after manufacturing is completed, will not be paid For purposes of warranty and service ONLY approved manufacturers or distributors authorized by an approved manufacturer to serve the Fort Collins area may bid The City of Fort Collins reserves the right to split the bid in whatever percentages are most advantageous to the City 0 "A rTNI [K] APPENDIX B REV SYM. HH Transformers purchased under this Specification shall be of the make shown below. Manufacturers not listed below may submit written proposals demonstrating compliance with these Specifications for consideration of addition to the accepted manufacturers list prior to the next request for bids. In addition to inclusion on the list below, manufacturer's equipment must also satisfy all requirements of this Specification to be acceptable TABLE IIIB MANUFACTURER SERIAL NO. Cooper Power Systems All ASEA Brown-Bovari All Howard Industries All Pauwels Transformers All The manufacturers in the following list have been conditionally approved and may bid as an alternate The definition and intent of "Conditional Approval" of a manufacturer is to allow the City to gain some experience with the manufacturer's product Should a conditionally approved manufacturer be the evaluated low bidder, the City reserves the right to award all, part, or none of the order to them, dependant upon the current needs of the City for that item or items 35 368-300 C7 APPENDIX C REV. SYM• CC The following forms for Individual and Average Transformer Losses are used by the City of Fort Collins to determine loss penalties 1) Transformer Loss Evaluation Average Losses Form 2) Individual Transformer Loss Evaluation Form 36 368-300 REV. SYM• CC City Order No Manufacturer KVA/Unit TRANSFORMER LOSS EVALUATION AVERAGE LOSSES S/N — Invoice No LINE DESCRIPTION (1) No. of units (2) Average core losses (3) Quoted core losses (4) Excess average core losses. line (2) less line (3) (5) Penalty for excess average core losses line (1) x line (4) x $ _ (6) Average copper losses (7) Quoted copper losses (8) Excess average copper losses line (6) less line (7) (9) Penalty for excess average copper losses line (1) x line (8) x $ (10) Penalty to be assessed manufacturer line (5) plus line (9) but not less than zero Prepared By Design Engineering AMOUNT NOTE If any unit(s) exceeds the loss tolerances of ANSI C57 12 00, Light & Power will either reject it, include it on these averages, or calculate losses using the Individual Transformer Losses Evaluation Form, whichever is most favorable to Light and Power 37 368-300 INDIVIDUAL TRANSFORMER LOSS EVALUATIOi4 City Order No. Manufacturer KVA/Unit S/N -- Invoice No REV SYM: EE LINE DESCRIPTION AMOUNT (1) Tested core losses (2) Quoted core losses (3) Excess core losses line (I) less line (2) but not less than zero (4) Percent difference line (3) — line (2) x 100 (5) Tested total losses (6) Quoted total losses (7) Excess total losses line (5) less line (6) but not less than zero (8) Percent difference line (7) — line (6) x 100 (9) Tested copper losses (10) Quoted copper losses (11) Excess copper losses line (9) less line (10) but not less than zero (12) Penalty for excess core losses line (3) x $ (13) Penalty for excess copper losses line (I1) x $ (14) Penalty to be assessed manufacturer line (12) plus line (13) Date Prepared By Design Engineering 38 368-306 Issued: 8/17172 Revised: 3/14/94 Revised: 12/13/96 Special Conditions and Supplemental Instructions to Bidders Applicable to Specification 368-300 A. Data to be Supplied with Bidder's Proposal The following data shall be supplied with the bidder's proposal in addition to that information required by the "Invitation to Bid" and the "Purchase Requisition". 1. Impedance volts in % at full load, high voltage to low voltage at 85°C. 2 No load and total losses at 85°C. 3. Delivery in weeks 4, A statement indicating compliance with our Specification without exception or a detailed list of exceptions. 5. Escalation is , is not applicable for the transformers bid. If escalation applies, the Bidder shall indicate in his bid the specific items or materials subject to escalation, and shall give the method and indices to be used in computing the amount thereof. Escalation occurring after the quoted delivery date will not be paid unless delays are the result of actions by the City. Escalation occurring after acceptance, if Purchaser exercises the option to delay shipment after manufacturing is completed, will not be paid If the above information and compliance statement are not supplied, the proposal will not be evaluated. An alternate bid for the total order may be submitted in addition to the unit bids. B Loss Evaluations Loss penalties and loss evaluations will be based on the following values 1 No load or excitation losses at $3 90/watt 2 Load losses at $2 30/watt. C. Shipping Terms Ship F.O.B. point of destination, freight prepaid. D. Terms of Payment 1. If escalation applies, the City of Fort Collins shall not be billed for escalation occurring after the promised delivery date. 2. Test reports shall accompany the invoice. If test reports do not accompany the invoice, late payment penalty charges incurred due to delays in obtaining the test reports will not be paid. Certified copies of test reports shall be sent to the Design Section, Fort Collins Light and Power Utility. 3. Loss penalty credits and escalation charges shall be itemized on the invoice. Purchase user ierm I 1 COMMERCIAL DETAILS Invoice Address To ensure prompt Payment mail invoices in duplicate to City of Fort Collins Accounting Division P 0 Box 580 Fort Collins, CO 80522 Tax exemptions By statute the City of Fort Collins is exempt from state and local taxes Our Exemption Number is 98-04502 Federal Excise Tax Exemption Certificate of Registry 84-6000587 is registered with the Collector of Internal Revenue, Denver, Colorado (Ref Colorado Revised Statutes 1973, Chapter 39-26, 114 (a) Goods Rejected GOODS REJECTED due to failure to meet specifications, either when shipped or due to defects of damage in transit, may be returned to you for credit and are not to be replaced except upon receipt of written instructions from the City of Fort Collins Inspection GOODS are subject to the City of Fort Collins inspection on arrival Final Acceptance Receipt of the merchandise, services or equipment in response to this order can result in authorized payment on the part of the City of Fort Collins However, it is to be understood that FINAL ACCEPTANCE is dependent upon completion of all applicable required inspection procedures Freight Terms Shipments must be F 0 B , City of Fort Collins, 700 Wood St , Fort Collins, CO 80522, unless otherwise specified on this order If permission is given to prepay freight and charge separately, the original freight bill must accompany invoice Additional charges for packing will not be accepted Shipment Distance Where manufacturers have distributing points in various parts of the country, shipment is expected from the nearest distribution point to destination and excess freight will be deducted from Invoice when shipments are made from greater distance Permits Seller shall procure at sellers sole cost all necessary permits, certificates and licenses required by all applicable laws, regulations, ordinances and rules of the state, municipality, territory or political subdivision where the work is performed, or required by any other duly constituted public authority having jurisdiction over the work of vendor Seller further agrees to hold the City of Fort Collins harmless from and against all liability and loss incurred by them by reason of an asserted or established violation of any such laws, regulations, ordinances, rules and requirements Authorization All parties to this contract agree that the representatives are, in fact, bona fide and possess full and complete authority to bind said parties LIMITATION OF TERMS This Purchase Order expressly limits acceptance to the terms and conditions stated herein set forth and any supplementary or additional terms and conditions annexed hereto or incorporated herein by reference Any additional or different terms and conditions proposed by seller are objected to and hereby rejected 2 DELIVERY PLEASE ADVISE PURCHASING AGENT immediately if you cannot make complete shipment to arrive on your promised delivery date as noted Time is of the essence Delivery and performance must be effected within the time stated on the purchase order and the documents attached hereto No acts of the Purchasers including, without limitation, acceptance of partial late deliveries, shall operate as a waiver of this provision In the event of any delay, the Purchaser shall have, in addition to other legal and equitable remedies, the option of placing this order elsewhere and holding the Seller liable for damages However, the Seller shall not be liable for damages as a result of delays due to causes not reasonably foreseeable which are beyond its reasonable control and without its fault of negligence, such acts of God, acts of civil or military authorities, governmental priorities, fires, strikes, flood, epidemics, wars or riots provided that notice of the conditions causing such delay is given to the Purchaser within five f5) days of the time when the Seller first received knowledge thereof In the event of any such delay, the date of delivery shall be extended for the period equal to the time actually lost by reason of the delay 3 WARRANTY The Seller warrants that all goods articles, materials and work covered by this order will conform with applicable drawings, specifications, samples and/or other descriptions given, will be fit for the purposes intended, and performed with the highest degree of care and competence in accordance with accepted standards for work of a similar nature The Seller agrees to hold the purchaser harmless from any loss, damage or expense which the Purchaser may suffer or incur on account of the Sellers breach of warranty The Seller shall replace, repair or make good, without cost to the purchaser, any defects or faults arising within one (1) year or within such longer period of time as may be prescribed by law or by the terms of any applicable warranty provided by the Seller after the date of acceptance of the goods furnished hereunder (acceptance not to be unreasonably delayed), resulting from imperfect or defective work done or materials furnished s ano wnmugns Aak by the Seller Acceptanqgr use of goods by the Purchaser shall not constitute a waiver of any claim under this warranty Except as otherwise provided in this purchase order, the Sellers liability hereunder shall extend to all damages proximately caused by the breach of any of the foregoing warranties or guarantees, but such liability shall in no event include loss of profits or loss of use NO IMPLIED WARRANTY OR MERCHANTABILITY OR OF FITNESS FOR PURPOS SHALL APPLY 4 CHANGES IN LEGAL TERMS The Purchaser may make changes to legal terms by written change order 5 CHANGES IN COMMERCIAL TERMS The Purchaser may make any changes to the terms, other than legal terms, including additions to or deletions from the quantities originally ordered in the specifications or drawings, by verbal or written change order If any such chang affects the amount due or the time of performance hereunder, an equitable adjustment shall be made 6 TERMINATIONS The Purchaser may at any time by written change order, terminate this agreemen as to any or all portions of the goods then not shipped, subject to any equitable adjustment between the parties as to any work or materials then in progress provided that the Purchaser shall not be liable for any claims for anticipated profit on the uncompleted portion of the goods and/or work, for incidental or consequential damages, and that no such adjustment be made in favor of the Seller with respect to any goods which are the Sellers standard stock No such termination shall relieve the Purchaser or the Seller of any of their obligations a to any goods delivered hereunder 7 CLAIMS FOR ADJUSTMENT Any claim for adjustment must be asserted within thirty (30) days from the dat the change or termination is ordered 8 COMPLIANCE WITH LAW The Seller warrants that all goods sold hereunder shall have been produced, sold delivered and furnished in strict compliance with all applicable laws and regulations to which the goods are subject The Seller shall execute and deliver such documents as may be required to effect or evidence compliance All laws an regulations required to be incorporated in agreements of this character are hereb incorporated herein by this reference The Seller agrees to indemnify and hold th Purchaser harmless from ail costs and damages suffered by the Purchaser as a result of the Sellers failure to comply with such law 9 ASSIGNMENT Neither party shall assign, transfer, or convey this order, or any monies due or t become due hereunder without the prior written consent of the other party 10 TITLE The Seller warrants full, clear and unrestricted title to the Purchaser for all equipment, materials and items furnished in performance of this agreement, fre and clear of any and all liens, restrictions, reservations, security interest encumbrances and claims of others 11 NONWAIVER Failure of the Purchaser to insist upon strict performance of the terms and conditions hereof, failure or delay to exercise any rights or remedies provided herein or by law, failure to promptly notify the Seiler in the event of a breach, th acceptance of or payment for goods hereunder or approval of the design, shall no release the Seller of any of the warranties or obligations of this purchase order an shall not be deemed a waiver of any right of the purchaser to insist upon strict performance hereof or any of its rights or remedies as to any such goods, regardless of when shipped, received or accepted, as to any prior or subsequen default hereunder, nor shall any purported oral modification or rescission of this purchase order by the Purchaser operate as a waiver of any of the terms hereof 12 ASSIGNMENT OF ANTITRUST CLAIMS Seller and the Purchaser recognize that in actual ec c practice overcharges resulting from antitrust violations are in fact borne b Purchaser Theretofore, for good cause and as consideration for executing this purchase order the Seller hereby assigns to the Purchaser any and all claims it may now have or hereafter acquired under federal or state antitrust jaws for such overcharges relating to the particular goods or services purchased or acquired by the Purchaser pursuant to this purchase order 13 PURCHASERS PERFORMANCE OF SELLERS OBLIGATIONS If the Purchaser directs the Seller to correct nonconforming or defective goods by a date to be agreed upon by the Purchaser and the Seller, and the Seller thereafter indicates its inability or unwillingness to comply, the Purchaser may cause the work to be performed by the most expeditious means available to it, and the Seller shall pay all costs associated with such work The Seller shall release the Purchaser and its contractors of any tier from all liability and claims of any nature resulting from the performance of such work This release shall apply even in the event of fault of negligence of the party released and shall extend to the directors, officers and employees of such party The Seller's contractual obligations, including warranty, shall not be deemed to be reduced, in any way, because such work is performed or caused to be performed by the Purchaser 14 PATENTS Whenever the Seller is required to use any design, device, material or process covered by letter, patent, trademark or copyright, the Seller shall indemnify and save harmless the Purchaser from any and all claims for infringement by reason of the use of such patented design, device, material or process in connection with the contract, and shall indemnify the Purchaser for any cost, expense or damage which it may be obliged to pay by reason of such infringement at any time during the prosecution or after the completion of the work In case said equipment, or any pan thereof or the intended use of the goods, is in such suit held to constitute infringement and the use of said equipment or part is enjoined, the Seller shall, at its own expense and at its option, either procure for the Purchaser the right to continue using said equipment or parts replace the same with substantially equal but non -infringing equipment or modify it so it becomes non -infringing 15 INSOLVENCY If the Seller shall become insolvent or bankrupt, make an assignment for the benefit of creditors, appoint a receiver or trustee for any of the Sellers property or business, this order may forthwith be canceled by the Purchaser without liability 16 GOVERNING LAW The definitions of terms used or the interpretation of the agreement and the rights of all parties hereunder shall be construed under and governed by the laws of the State of Colorado, USA The following Additional Conditions apply only in cases where the Seller is to perform work hereunder, including the services of Sellers Representative(s), on the premises of others 17 SELLERS RESPONSIBILITY The Seller shall carry on said work at Seller's own risk until the same is fully completed and accepted, and shall, in case of any accident, destruction or injury to the work and/or materials before Seller's final completion and acceptance, complete the work at Seller's own expense and to the satisfaction of the Purchaser When materials and equipment are furnished by others for installation or erection by the Seller, the Seller shall receive, unload, store and handle same at the site and become responsible therefor as though such materials and/or equipment were being furnished by the Seller under the order 18 INSURANCE The Seller shall, at his own expense, provide for the payment of workers compensation, including occupational disease benefits, to its employees employed on or in connection with the work covered by this purchase order, and/or to their dependents in accordance with the laws of the state in which the work is to be done The Seller shall also carry comprehensive general liability including, but not limited to, contractual and automobile public liability insurance with bodily injury and death limits of at least $300,000 for any one person, $500,000 for any one accident and property damage limit per accident of $400,000 The Seller shall likewise require his contractors, if any, to provide for such compensation and insurance Before any of the Sellers or his contractors employees shall do any work upon the premises of others the Seller shall furnish the Purchaser with a certificate that such compensation and insurance have been provided Such certificates shall specify the date when such compensation and insurance have been provided Such certificates shall specify the date when such compensation and insurance expires The Seller agrees that such compensation and insurance shall be maintained until after the entire work is completed and accepted 19 PROTECTION AG ACCIDENTS AND DAMAGES The Seller hereby assu _ the enure responsibility and liability for any and all damage loss or injury of any kind or nature whatsoever to persons or property caused by or resulting from the execution of the work provided for in this purchase order or in connection herewith The Seller will indemnify and hold harmless the Purchaser and any or all of the Purchasers officers, agents and employees from and against any and all claims, losses, damages, charges or expenses whether direct or indirect, and whether to persons or property to whit the Purchaser may be put or subject by reason of any act, action, neglect, omission or default on the part of the Seller, any of his contractors, or any of th Sellers or contractors officers, agents or employees In case any suit or other proceedings shall be brought against the Purchaser, or its officers, agents or employees at any time on account or by reason of any act, action, neglect, omission or default of the Seller of any of his contractors or any of its or their officers, agents or employees as aforesaid, the Seller hereby agrees to assume th defense thereof and to defend the same at the Sellers own expense, to pay any and all costs, charges, attorneys fees and other expenses, any and all judgment that may be incurred by or obtained against the Purchaser or any of its or their officers, agents or employees in such suits or other proceedings, and in case judgment or other lien be placed upon or obtained against the property of the Purchaser, or said parties in or as a result of such suits or other proceedings, th Seller will at once cause the same to be dissolved and discharged by giving bon or otherwise The Seller and his contractors shall take all safety precautions, furnish and install all guards necessary for the prevention of accidents, comply with all laws and regulations with regard to safety including, but without limitation, the Occupational Safety and Health Act of 1970 and ail rules and regulations issued pursuant thereto 9/90 Revised 11/91 Bid #5406 SUPPLEMENTAL INSTRUCTIONS Prices quoted must remain firm for a 30 day period after the opening date Freight terms F 0 B destination freight prepaid All freight charges must be included in pricing submitted on proposal and not entered as separate pricing Any discount allowed by Vendor for prompt payment, etc must be reflected in quoted figure, and not entered as separate pricing The City reserves the right to accept or reject any and all quotes Bidder not responding to the services requested in this bid shall be removed from our automated listing for Not applicable Any questions or inquiries regarding this bid should be directed to Opal F. Dick, CPPO, Senior Buyer (970) 221-6778 SIGNATURE AND TITLE TYPED OR PRINTED NAME AND TITLE COMPANY NAME (AREA CODE) TELEPHONE NO /FAX NO ADDRESS STREET, CITY, STATE, ZIP DATE 5 REV SYM II THE CITY OF FORT COLLINS Light and Power Department P O Box 580 Fort Collins, CO 80522 SPECIFICATION NO 368-300 TITLE PAD -MOUNTED COMPARTMENTAL -TYPE THREE-PHASE DISTRIBUTION TRANSFORMERS WITH SEPARABLE INSULATED LOAD BREAK HIGH -VOLTAGE CONNECTORS APPROVED BY A' 6w Tim M Sagen Design Engineer DATE 8/12/83 REVISED 6/3/99 i 368-300 REV SYM CC ITEMS COVERED BY THIS SPECIFICATION DESCRIPTION STOCK NO SPECIFICATION NO SERIAL 75 KVA, 208Y/120 Radial 368-300 -006 75 KVA, 480Y/277 Radial 368-300 -007 75 KVA, 208Y/120 Loop 368-300 -008 75 KVA, 480YI277 Loop 368-300 -009 150 KVA, 208Y/120 Loop 368-300 -015 150 KVA, 480Y/277 Loop 368-300 -016 300 KVA, 208Y/120 Loop 368-300 -030 300 KVA, 480Y/277 Loop 368-300 -031 500 KVA, 208Y/120 Loop 368-300 -050 500 KVA, 480Y/277 Loop 368-300 -051 750 KVA, 208Y/120 Loop 368-300 -075 750 KVA, 4BOY1277 Loop 36B-300 -076 1000 KVA, 208Y/120 Loop 368-300 -100 1000 KVA 480Y/277 Loop 368-300 -101 1500 KVA, 480Y/277 Loop 368-300 -151 2000 KVA, 480Y/277 Loop 368-300 -201 2500 KVA, 480Y/277 Loop 368-300 -251 368-300 REV SYN II PREVIOUS REVISION DESCRIPTIONS ON FILE REVISION DESCRIPTION APPROVED Tim Sagen REVISION FF Add Paragraph 5 2 2 9 3 Susan Corer, pentahead locking bolts 10-18-95 Paragraph 3 2 2 13 1 add glossy Requirement Susan Coram REVISION GG Title page Remove revised date Tim Sagan Paragraph 4 4 and Table II 9-22-95 Change Temperature Tests and Noise Test from every unit to one unit of aesign Opal Dick REVISION HH Title Page Add revision date Tim Sagan 12-13-96 GE removed from Appendix B REVISION II Add paragraph 3 2 2 10 OVERCURRENT Tim Sagen PROTECTION and renumber remaining 6/3/99 paragraphs in section 3 2 Revise Fig 1 to reflect a "V" configuration for the primary bushing arrangement vs an in line arrangement Revise Fig 17 to remove requirement for CT mounting studs and increase dimension A from 5 and 5 5" to 6" on 225-2500 kVA sizes 3 368-300 LIB C] REV SYM II LIST OF ACTIVE PAGES ORIGINAL PAGES ORIGINAL PAGES ADDED PAGES SHEET NO REV SYM SHEET NO REV SYM SHEET NO REV SYM 1 II 29 DD 2 CC 30 CC 3 II 31 CC 4 II 32 HE 5 CC 33 CC 6 CC 34 CC 7 CC 35 HH 8 CC 36 CC 9 EE 37 cc 10 cc 38 EE 11 Cc 12 II �3 I1 14 cc I 15 cc 16 CC 17 II 18 CC 19 CC 20 LE 21 EE 22 CC 23 CC 24 EE 25 CC 2E EE 27 F,E 26 GG 4 368-300