Loading...
HomeMy WebLinkAboutRESPONSE - BID - 5406 LP TRANSFORMERS 150 300KVA (3)�0 FIRM NAME /A),66 e-i n all7k7 ka CITY OF FORT COLLINS BID PROPOSAL BID NO 5406 BID OPENING 2 00 p m (our clock) August 4, 1999 WE HEREBY ENTER OUR BID FOR THE CITY OF FORT COLLINS' REQUIREMENTS FOR TRANSFORMER, 150 KVA, 300 KVA PER THE BID INVITATION AND ANY REFERENCED SPECIFICATIONS QUANTITY DESCRIPTION* 15 Ea Transformer, 150 KVA pad -mounted compartmental -type, three phase distribution with separable insulated load break high -voltage connectors High voltage rating 13200 GRDY/7620 Low voltage rating 208Y/120 Serial number 015 to be in accordance with Specification #368-300- 015, Revision If $ S/76,, °O Ea $ 7764() °� Total Delivery in weeks ARO /7—/9 Mfr & Mfr # TaVwG�S The transformers being bid meet or exceed the specifications _J/es No If not, please list exceptions, (specifying paragraph reference number) on a separate sheet of paper and attach to your bid Guaranteed No Load Loss 37& Guaranteed Full Load Loss 888 Guaranteed Total Load Loss 1264 impedance (%)%) / 99 Escalation is , is not ✓ applicable for the transformers bid If escalation applies, the bidder shall indicate in his bid the specific items or materials subject to escalation, and shall give the method and indices to be used in computing the amount thereof Escalation occurring after the quoted delivery date will not be paid unless delays are the result of actions by the city Escalation occurring after acceptance if purchaser exercises the option to delay shipment after manufacturing is completed, will not be paid 3 1 Firm Name Un//&n Elt�a QUANTITY DESCRIPTION 4 Ea Transformer, 300 KVA pad -mounted compartmental -type three phase distribution with separable insulated load break high -voltage connectors High voltage rating 13200 GRDY/7620 Low voltage rating 208Y/120 Serial number 030 to be in accordance with Specification #368-300-030, Revision II $ 4401 oo Ea $ 25-,604 ° Total Delivery in weeks ARO 24-24 Luks Mfr & Mfr # {�o Iar� p oT/e'CT-2840 Guaranteed No Load loss S/7 Guaranteed Full Load Loss 209:!e Guaranteed Total Load Loss 261// Impedance (%) 2•CP Yes ZNo _ If not, please list exceptions (specifying paragraph reference number) on a separate sheet of paper The transformers being bid meet or exceed the attached specifications and attach to your bid documents Escalation is is not -,,—/ applicable for the transformers bid If escalation applies, the bidder shall indicate in his bid the specific items or materials subject to escalation, and shall give the method and indices to be used in computing the amount thereof Escalation occurring after the quoted delivery date will not be paid unless delays are the result of actions by the city Escalation occurring after acceptance if purchaser exercises the option to delay shipment after manufacturing is completed, will not be paid For purposes of warranty and service ONLY approved manufacturers or distributors authorized by an approved manufacturer to serve the Fort Collins area may bid. The City of Fort Collins reserves the right to split the bid in whatever percentages are most advantageous to the City 2 0 SUPPLEMENTAL INSTRUCTIDNS Prices quoted must remain firm for a 30 day period after the opening date Freight terms F O B destination freight prepaid All freight charges must be included in pricing submitted on proposal and not entered as separate pricing Any discount allowed by Vendor for prompt payment, etc must be reflected in quoted figure, and not entered as separate pricing The City reserves the right to accept or reject any and ail quotes Bidder not responding to the services requested in this bid shall be removed from our automated listing for Not applicable Any questions or inquiries regarding this bid should be directed to Opal F Dick, CPPO, Senior Buyer (970) 221-6778 SIGNATURE AND TITLE / TYPED OR PRINTED NAMFF AND TITLE t ��C 303-45 -? 25-433-��43 COMPANY NAME (AREA CODE) LEPHONE NO /FAX NO 80 z. // "7Z % ADDRESS STREET, CITY, STATE, ZIP AT 5 Howard Industries, me HOWARD Hi INDUSTRIES P 0 Box 1588merDlvrean P 0 Box 1588 Laurel, MS 39441-1588 Phone 601 425 3151 Fax 601 649 W90 WESTERN UNITED ELEC FOB DESTINATION Validity 30 DAYS 1313 W 46TH AVENUE Pricing FIRM FOR QUOTED SHIPMENT DENVER, CO 80211 Inquiry CITY OF FT COLLINS .. > lug' a �a •. f5,,. ' .etl ` :>[ >`� >� s s. 'I >>�"` •> ITEM 1 S G z ITEM 2 15 4 ;_,,, escnphan PRODUCT, 3-PHASE PAD MOUNT ANSI C57 12 26 DEAD FRONT SINGLE VOLTAGE KVA 150 KVA HV: 13200GRDY/7620 + GRD 95KV BIL LV: 20BY/I20 30KV BIL TAPS: (2) 2-1/2 ABOVE & BELOW LOSSES NO LOAD = 277, LOAD = 1110, TOTAL = 1387, IMPED = 2.2 "K nit INIBFF/- 01 F PRODUCT. 3-PHASE PAD MOUNT ANSI C57 12 26 DEAD FRONT SINGLE VOLTAGE KVA, 300 KVA HV: 13200GROY/7620 + GRD 95KV BIL LV. 20BY/120 30KV BIL TAPS' (2) 2-1/2 ABOVE & BELOW LOSSES, NO LOAD = 517, LOAD = 2094, TOTAL = 2611, IMPED = 2 6 STOCK NUMBER 030 LOW TOC PER SPEC 368-300 REV II DATED 6-3-99 ORDERS REQUIRING APPROVAL DRAWINGS. LEADTIMES QUOTED ASSUME THAT APPROVAL DRAWINGS WILL BE SIGNED AND RETURNED TO HOWARD INDUSTRIES WITHIN TWO WEEKS OF RECEIPT OF SAID DRAWING SHOULD THE PROCESS REQUIRE ANY ADDITIONAL TIME BEYOND THESE TWO WEEKS, THAT ADDITIONAL TIME WILL BE ADDED TO THE QUOTED LEADTIME. QUU I A I IVIY Quotation No CJ-2940 Quotation Date Jul 20 1999 Page No 1 = �,<t1o14Pnce „Shiprtlent AI *4620-°C' 1 24-26 WKS 124-26 WKS UNCONTROLLED COPY LAST PAGE SUBMITTED BY CLARICE JONES aoLT wt ,Mr¢M rt5S 1 ILV BUSH k 4 HOLE SPADE 3 1/2-13 GROUND PAD 4 HV BUSH DF WELL 5 LOAD BREAK PKG STAND 7 NP ON DOOR SER ON TANK 8 TANK JIFTING LUGS JACKING PROVISIONS 1/2-13 GROUND PAD 1 IN DRAIN VALVE AND SAMPU PAD LOCKABLE DOOR HANDLE 3 PT LATCH PENTA SEC BOLT 6 IN REMOVABLE Sn.L METAL LV-HIV BARRIER PRESS REL VALVE DIAL THERM W/MAX POINTER OIL LEVEL PLUG TAP CHANGER HANDLE I" UPPER FILTER PRESS CONK r 60 HOWARD U INDUSTRIES INC. LAUREL, MISS. USA 39440 HREE PHASE DISTRIBUTION TRANSFORMERS cyr klro FORT COLLINS. CO. OIL NOTE THE WEIGHTS AND DIMENSIONS ARE APPROXIMATE AND SUBJECT TO CHANGE WITHIN THE CUSTOMER SPECIFIED LIMITS. APPROVAL DRAYANGS WITH THE ACTUAL WEIGHTS AND IM S10)-N5 WLL BE PROVIDED UPON REQUEST AFTER R T OF ORDER WnTr-ftrT MENSIONS IN INC 0 m 1 n m DESCRIPTION SH, & 4 HOLE SPADE 3 GROUND PAD ISH OF WELL BREAK PKG STAND I DOOR SER ON TANK HANDHOLE & SECURITY COVER LIFTING LUGS JACKING PROVISIONS 1/2-13 GROUND PAD 1 IN DRAIN VALVE AND SAMPLER PAD LOCKABLE DOOR HANDLE 3 PT LATCH PENTA SEC BOLT 6 IN REMOVABLE SILL METAL LV-HV BARRIER PRESS REL VALVE DIAL THERM W AAX POINTER 2- MAG LL GAUGE: LV COMP OIL LEVEL PLUG TAP CHANGER HANDLE 1" UPPER FILTER PRESS CONN PROVISION FOR PRES VAC GAUGE LIMITING 61 55 P; HOWARD U INDUSTRIES INC LAUREL, MISS. USA 39440 THREE PHASE DISTRIBUTION TRANSFORMERS rr urn _ FORT COLLINS, CO NOTE THE WEIGHTS AND DIMENSIONS ARE APPROMMATE AND SUBJECT TO CHANGE WITHIN THE CUSTOMER SPECIFIED LIMITS APPROVAL DRAWINGS WITH THE ACTUAL WEIGHTS AND DIMENSIONS WILL BE PROVIDED UPON REQUEST AFTER 7ns T OF ORDER. NOTE (1) DIMENSIONS IN INC f2Y14EIGHTS IN POUND I L 3> FIRM NAME A),I CITY OF FORT COLLINS BID PROPOSAL BID NO 5406 BID OPENING 2 00 p m (our clock) August 4, 1999 WE HEREBY ENTER OUR BID FOR THE CITY OF FORT COLLINS' REQUIREMENTS FOR TRANSFORMER, 150 KVA, 300 KVA PER THE BID INVITATION AND ANY REFERENCED SPECIFICATIONS QUANTITY DESCRIPTION 15 Ea Transformer, 150 KVA pad -mounted compartmental -type, three phase distribution with separable insulated load break high -voltage connectors High voltage rating 13200 GRDY/7620 Low voltage rating 208Y/120 Serial number 015 to be in accordance with Specification #368-300- 015, Revision II $ 5254 Sn Ea $ 7$8/0. oo Total Delivery in weeks ARO 24-210 1 Mfr & Mfr #t"try /f!/t CuozeCT2 The transformers being bid meet or exceed the specifications __ZYes No If not, please list exceptions, (specifying paragraph reference number) on a separate sheet of paper and attach to your bid Guaranteed No Load Loss /22 Guaranteed Full Load Loss /023 Guaranteed Total Load Loss //49- Impedance M 2, 3 Escalation is , is not Z applicable for the transformers bid If escalation applies, the bidder shall indicate in his bid the specific items or materials subject to escalation, and shall give the method and indices to be used in computing the amount thereof Escalation occurring after the quoted delivery date will not be paid unless delays are the result of actions by the city Escalation occurring after acceptance if purchaser exercises the option to delay shipment after manufacturing is completed, will not be paid 3 Firm Name L t/c_57c� r� Uni/c�J QUANTITY DESCRIPTION 4 Ea Transformer, 300 KVA pad -mounted compartmental -type three phase distribution with separable insulated load break high -voltage connectors High voltage rating 13200 GRDY/7620 Low voltage rating 208Y/120 Serial number 030 to be in accordance with Specification #368-300-030, Revision 11 $ 7498. 00 Ea $ 29, 992 O2 Total Delivery in weeks ARO 24-24 Mfr & Mfr # "O /o %R/ 400Ya CT-284� .. orP ass Guaranteed No Load loss 199 Guaranteed Full Load Loss 2010 Guaranteed Total Load Loss 22(g8 Impedance (%) 29 Yes V No _ If not, please list exceptions (specifying paragraph reference number) on a separate sheet of paper The transformers being bid meet or exceed the attached specifications and attach to your bid documents Escalation is , is not -,—/ applicable for the transformers bid. If escalation applies, the bidder shall indicate in his bid the specific items or materials subject to escalation, and shall give the method and indices to be used in computing the amount thereof Escalation occurring after the quoted delivery date will not be paid unless delays are the result of actions by the city Escalation occurring after acceptance if purchaser exercises the option to delay shipment after manufacturing is completed, will not be paid For purposes of warranty and service ONLY approved manufacturers or distributors authorized by an approved manufacturer to serve the Fort Collins area may bid The City of Fort Collins reserves the right to split the bid in whatever percentages are most advantageous to the City 4 0 Bid #5406 SUPPLEMENTAL INSTRUCTIONS Prices quoted must remain firm for a 30 day period after the opening date Freight terms F 0 B destination freight prepaid All freight charges must be included in pricing submitted on proposal and not entered as separate pricing Any discount allowed by Vendor for prompt payment, etc must be reflected in quoted figure, and not entered as separate pricing The City reserves the right to accept or reject any and all quotes Bidder not responding to the services requested in this bid shall be removed from our automated listing for Not applicable Any questions or inquiries regarding this bid should be directed to Opal F Dick, CPPO, Senior Buyer (970) 221-6778 SIGNATURE AND TITLE PED OR PRINTED NAME COMPANY NAME /3/3 ADDRESS (AREA CODE) ET, CITY, STATE, ZIP 80 2 0 —/4 ) TITLE 303— 433—�3 NO /FAX NO 5 Howard Industries. me Utility Transtolmel Division HOWARD [9 INDUSTRIES PO Box ISM Laurel, MS 35441-15BB Phone 601 4251151 Fax 601 649 8090 WESTERN UNITED ELEC FOB DESTINATION Validity 30 DAYS 1313 W 46TH AVENUE Prtciag FIRM FOR QUOTED SHIPMENT 11 DENVER, CO 80211 Inquiry FT. COLLINS '(Itv" N W. ITEM 1 ITEM 2 15 Ell PRODUCT 3-PHASE PAD MOUNT ANSI C57.12,26 DEAD FRONT SINGLE VOLTAGE KVA 150 KVA HV- 13200GRDY/7620 + GRD 95KV BIL LV 20BY/120 30KV BIL TAPS 12) 2.112 ABOVE & BELOW LOSSES NO LOAD = 122, LOAD = 1023, TOTAL = 1145, IMPED = 2.3 iST.^.CK KilMARPA. ()1R PRODUCT, 3-PHASE PAD MOUNT ANSI C57.12 26 DEAD FRONT SINGLE VOLTAGE KVA 300 KVA HV. 13200GRDY/7620 + GRD 95KV BIL LV, 20SY/I20 30KV BIL TAPS, (2) 2-1/2 ABOVE & BELOW LOSSES. NO LOAD = 198, LOAD = 2070, TOTAL = 2268, IMPED = 2 9 STOCK NUMBER. 030 PER SPEC 368-300 REV 11 DATED 6-3-99 AMORPHOUS ALT. OF CJ-2B40 ORDERS REQUIRING APPROVAL DRAWINGS, LEADTIMES QUOTED ASSUME THAT APPROVAL DRAWINGS WILL BE SIGNED AND RETURNED TO HOWARD INDUSTRIES WITHIN TWO WEEKS OF RECEIPT OF SAID DRAWING SHOULD THE PROCESS REQUIRE ANY ADDITIONAL TIME BEYOND THESE TWO WEEKS, THAT ADDITIONAL TIME WILL BE ADDED TO THE QUOTED LEADTIME. UNCOr4TRO1,LED COPY ., ' 1 n' I"" nIJVO LAST PAGE QUU 1 A t! ►v►v Quo4ttoR No QuolaUoR Date Page No ,. ��,,8ni2Pnta° 5254 s SUBMITTED BY CLARICE JONES CJ-2841 Jul 20 1999 1 124.26 WKS B 124-26 WKS N O DESCRIPTION 7 LV BUSH. & 4 HOLE 3 1/2-13 GROUND PAD 4 IHV BUSH OF WELL 7 NP ON DOOR SER ON TANK 8 TANK in IWANDHOI F & SECURITY COVER /2-13 GROUND PAD IN ORAIN VALVE AND SAMPLER AD LOCKABLE DOOR HANDLE PT LATCH PENTA SEC BOLT I., nf',.IO:�BLE cu 47 PRESS REL EVALVE48 DIAL THERM ER 50 01l LEVEL P5T TAP CHANGE52 1" UPPER FICo I sn n 400 HOWARD U INDUSTRIES INC. LAUREL, MISS USA 39440 THREE PHASE DISTRIBUTION TRANSFORMERS ni ic7nuro FORT COLLINS, CO. NOTE THE WEIGHTS AND DIMENSIONS ARE APPROXIMATE AND SUBJECT TO CHANGE WITHIN THE CUSTOMER SPECIFIED LIMITS. APPROVAL DRA87NGS MTH THE ACTUAL WFJGHTS AND DIMENSIONS WILL BE PROVIDED UPON REQUEST AFTER RE OF ORDER • OTT' (11 DIM S10NS IN INCHES AP Firm Name /,( l/sited I1 C. - QUANTITY DESCRIPTION 4 Ea Transformer, 300 KVA pad -mounted compartmental -type three phase distribution with separable insulated load break high -voltage connectors High voltage rating 13200 GRDY/7620 Low voltage rating 208Y/120 Serial number 030 to be in accordance with Specification #368-300-030, Revision If $ 647/ e2� Ea $ 25 �� �� Total Delivery in weeks ARO /7— /9 Mfr & Mfr # /' UtAZt /S Guaranteed No Load loss 52$ Guaranteed Full Load Loss 9pS' Guaranteed Total Load Loss 24ZS Impedance (%) 2.4� Yes ✓ No _ If not, please list exceptions (specifying paragraph reference number) on a separate sheet of paper The transformers being bid meet or exceed the attached specifications and attach to your bid ocuments Escalation is is not applicable for the transformers bid If escalation applies, the bidder shall indicate in his bid the specific items or materials subject to escalation, and shall give the method and indices to be used in computing the amount thereof Escalation occurring after the quoted delivery date will not be paid unless delays are the result of actions by the city Escalation occurring after acceptance if purchaser exercises the option to delay shipment after manufacturing is completed, will not be paid For purposes of warranty and service ONLY approved manufacturers or distributors authorized by an approved manufacturer to serve the Fort Collins area may bid The City of Fort Collins reserves the right to split the bid in whatever percentages are most advantageous to the City 4 on DESCRIPTION DWG No. J 4 0 2 HOWARD ® INDUSTRIES INC. LAUREL, MISS USA 39440 THREE PHASE DISTRIBUTION TRANSFORMERS 760 CUSTOMER • FORT COLLINS, CO 70 SPEC 368-300 DATED 09 5 ------ -T7 KVA 300 OBIL 95 TAPS TS-Z ABOVE-k BELO HIGH VOLTAGE 0 G 6 O LOW VOLTAGE APPROX. CORE AND COIL WEIGHT 619 i �--------J i APPROX, TANK AND ACCESS WEIGHT 1388 vi GAL. [IF DLL 3811 APPRDX. WEIGHT 858 - APPROX TOTAL WEIGHT 6 �___ —y3, N A i REV. GATE DESCRIPTION Y P El { D 3 CJ0215 `------------------ -- -------- NOTE THE HEIGHTS AND DIMENSIONS ARE APPROXIMATE 5 AND SUBJECT TO CHANGE WITHIN THE CUSTOMER SPECIFIED LIMITS APPROVAL ORAWNGS WITH H1LL BE 52 48 7 57 4 THE PROVIDED U ON7GHT5 AND FT E RECEIqONSPT 5 4 PROVIDED UPON REQUEST AFTER RECEIPT "DER 51 49 12 IN INCHES 10 50 )HEIGHTS IN POUNDS 8 i 400 2 45 ©� �© ® ^ 21 •� - /!� 10 1 • 3 r o 13 i=7= 0 1 LV BUSH & 4 HOLE SPADE 3 t 2-13 GROUND PAD 4 HV BUSH DF WELL 5 LOAD BREAK PKG STAND 7 NP ON DOOR SER ON TANK B TANK 10 HANDHOLE & SECURITY COVER 12 LIFTING LUGS 13 JACKING PROVISIONS 14 t 2-13 GROUND PAD 15 1 IN GRAIN VALVE AND SAMPLER 21 PAD LOCKABLE DOOR HANDLE 22 3 PT LATCH PENTA SEC BOLT 24 6 IN REMOVABLE SILL 25 METAL LV-HV BARRIER 47 PRESS REL VALVE 48 DIAL THERM W AX POINTER 49 2" MAC ILL GAUCE LV COMP 50 OIL LEVEL PLUG 51 TAP CHANGER HANDLE 52 1" UPPER FILTER PRESS CONN 57 PROVISION FOR PRES VAC GAUGE SPECIAL NOTES g CURRENT LIMITING FUSE c D E AT NO 91 BY C DATES 07 17 99 PP BYE 74W CC 5 Bid #5406 SUPPLEMENTAL INSTRUCTIONS Prices quoted must remain firm for a 30 day period after the opening date Freight terms F 0 B destination freight prepaid All freight charges must be included in pricing submitted on proposal and not entered as separate pricing Any discount allowed by Vendor for prompt payment, etc must be reflected in quoted figure, and not entered as separate pricing The City reserves the right to accept or reject any and all quotes Bidder not responding to the services requested in this hid shall be removed from our automated listing for- Not applicable Any questions or inquiries regarding this bid should be directed to Opal F Dick, CPPO, Senior Buyer (970) 221-6778 SIGNATURE AND TITLE / TYPED OR PRINTED NAM ND TITLE y � 303 - 45 -27i '3COMPANY NAME (AREA CCODE)LEPHONE NO /FAX/NO '�' �vB.-�enver C D Sr02// '7�//39 ADDRESS STREET, CITY, STATE, ZIP AT 5 oT 20/99I rf '3R5" PA„y h J .r. r� t, ,1 r ' • R MERS QUOTATIONNUMBER K0716010 ITEMNUNLBER• 02 U=tiZT PRICE' S G471 � BILL OF MATERIAL OUANTIIY• 4 EXTFYDEiD PRICE: $ 2SP84 O° kVARarme- 300 MODEL#: Z13030132A200243 Three Phase Pad -Mount Tfansformer(s) COOLING CLASS• OA Muted Oil Immersed TREOUENCY- 60 Hz AVG WINDINGTEMP.RISE• 65-C PRIMARY VOLTAGE- 13200 GrdY/7620 Volts SECONDARY VOLTAGE- 208Y/120-Volts PRINL&RY BIL R-ATING: 95 kV SECONDARY BIL RATIISG 30 kV HV WINDING MATERIAL: LV WINDING MATERIAL, HIGH VOLT AGE TAPS. Two 2 5%'Paps below Nominal and Two 2 5% Taps above Nominal NO LOAD LOSS 52� V Utts LOAD LOSS 3905 Wptt TOTAL LOSS, 2133 IMPEDANCE 259% TANK & ENCLOSURE- Dolted Cover Cabinet Depth 19 Inches w/Pentahead Bolts Steel HV/LV Barnet BUSHINGS. Loop Feed Custom Dimensions Dead Front Primary Terminations- Wells, (6) Inserts Secondary Terimnahons Epoxy Bushmgs wTIhread-on 4 Hole Aluminum H Spades PROTECTION PRCLF (R-M ELSP 80A / 8 3kV). Weak Lmk Carhdge (RTE FAULT CIO / I5k4i� ACCESSORIES Pressure Relief Vah e Quahtrol202-037-01, Drain Valve w/Sampler Liquid Temperatur, Gauge SWITCff qG HQX0 Removable Link _ FA_NT COLOR DESERT TAN (NfUNSELL 10YR6 0/3/0), Coal Tar Over Powder STANDARDS. Quoted in compliance with the latest applicable ANSI sGuidards unless otherwise specified by the customer SHIPMENT IN 17 TO 19 WEEKS AFTER RECEIPT OF ORDER LLJUUJ UU0 OUOTATION COMMENTS ESCALATION IS NOT APPLICABLE FOR THIS TRANSFORMER BID PALtiVELS STANDARD TANK LEAK TEST ONLY WILL BE PERFORMED ON EACH UNIT IFATFMPF.RATURE RISF AND SOLND I FVFLTEST ARE REQUIRED ON ONE UNIT OF EACH DESIGN PER ORDER, PLEASE NOT THE COSTS OF SUCH TESTS ARE SGLq,!D LEVEL TEST M 600 00 T EMPERATTJRE RISE TEST 52400 00 07 '2 0 99 15 aS Fa\ 314 239 PaLVVELS TR:1\5 L,'_.UU- uu0 QUOTATIONNUMBER. K0716010 ITEtiINUNIBER 01 UNIT PRICE, S 5170 '�2 BILL OF MATERIAL QUANTITY! is EXTENDED PRICE- S 177, 640 00 KV A Ratme. 150 MODEL 4 Z13015132jV200241 Three Phase Pad -Mount Trra sformet(s) COOLING CLASS. OA Mineral Oil Immersed FREOUENCY. 60 Hz AVG WINDING TENIP. RISE' 65 IC PRINLARY VOLTAGE: 13200 GrdY/7620 Vo1G SECONDARY VOLTAGE: 208Y/120'Volts PRIMARY BIL RATING• 95 kV SECONDARY BIL RATING. 30 kV HV '.VLNDING MATERIAL- LV WINDING MATERIAI,: HIGH VOLTAGE TAPS Two 2 5% Taps below Nominal and Two 2 5%Taps above Nominal NO LOAD TOSS- 376 Watts LOADLOSS* FSR tVftms TOTAL I OSS 3264 IIh1I1P,llAICCE 199 TANK & ENCLOSURE Bolted Cover Cabinet Depth 19 Tnches w/Pentahead Bolts Steel HV/LV Barrier BUSIIENGS- Loop Feed Cristom Dimension, Dead Front PrimaD Te;.nmahons Wells, (6) Inserts Secondary Tmmiatons Epox} Buchmgs wlPhread-on 4 Hole Alum num H Spades PROTECTION: PRCLF (PTE ELSP 50A / 8 3kV) Weak Link Cartdge (RTE FAULT C07 / 15kV) .ACCESSORIES. Pressure Rehef Valve Quabtrol 202-037-01, Drain Plug Liquid Temperature Gauge MN`1TCHING HOXO Removable Link PAINI COLOR' DESERT TAN NU-N. SELL I0YR6 0/3/0), Coal Tar Over Poµ der STANDARDS Quoted m compliance with the latest appheable ANSI standards unless otherw%se speafiedby the customer' SHIPMENT IN 17 TO 19 WEEKS AFTER RF,CEIPT OF ORDER OUOTATION COMMENTS. ESCALATION IS NOTAPPLICABLE FORTHIS TRgNSFORMER BID FAU%%'ELS STANDARD TANK LEAKTEST ONLY WILL BE PERFORMED ON EACH UNIT IF A TFMPRRATURF RISE AND SOUND LEVEL TEST ARE REQUIRED ON ONE UN71T OP EACH DESIGN PER ORDER, PLEASE NOT THE COSTS OF SUCH TESTS ARE SOUND LEVEL TESL- S1600 00 TE%IPERATURE RISE TEST $2400 00 07/20/99 15 49 FAX 314 299 9072 PAUWELS TRANS lihG04/006 COLUNJS 07 '20/99 15 49 FAX 314 239 U12 PALIWELS TRANS Z 005/006 ALL FFEMS MARKED ' ® ' ARE INCLUDED FFEM NO. DESCRIPTION fFEM NO. DESCRIPTION High Volta a Bushings Raised Air Compartment Wells Top For Bay- -Net Fuse Load Break Inserts Replacement 20 Load Break Integral 21 jacking Provisions 11- Livefront Porcelain 22 Cooling Fins Low Voltage Bushings Tap Changer Studs A' Taos -2.5% -5% -7 5% -10% 4 Hole Spade B Ta s +5% +2.5% -2 5% -5% 6 Hole Spade 11C Taos 6 Hole Su orted J Spade 11 Ta s 23 8 Hole SuRported J Spade 24 HoXo Switch 10 Hole Supported J Spade 'vv C4 e Fwse 2 112 Hole SUDDorted J Spade 25 Dual Sensing 3 XParking Stand Current Sensing 4 Pressure Relief Valve 26 CTC Plastic Drip Cu Provision For Liquid Level Ga Door Holding Bars 120' Open 51, 27 X Liquid Level Gauge Position Provision For Liquid Temp. Go. Internal Under Oil Current Liquid Temperature Gauge Limitin Fuses 6' 28 7 Oil Fill Plug29 Paint Munse11 fJese Ta Oil Drain Plug 30 Additional Protective Coating Oil Drain Plug And Sampler 31 Hi h - Low Barrier Oil Drain Valve 32 St<rinless Steel Hinges 8 1 10il Drain Valve And Sampler 33 All Bushings Are Externoll 9 Name late clamped nd Pads 34 Bolted Cover 10ole Ground Pads 35 Pressure Voc Guo e 11 Voltage Ground Strop 12ision 13 For Lifting ock FacilityAnd Door Bolt tahead Bolt EHexhecid Bolt14 A EI - 8 Voltage Door Handle XRemovable Lower Front Sill E - -2-715 F - l<5f-- Base Arrangement For Rollin G - �z 16 In Two Directions H - 47/5 17 Transformer Tank 18lHigh 19 Low Voltage Compartment Door Voltage Compartment Door _ K - �1(z L 4k — ISO Hv - 13200OrdY %(OZO N - �o L-v - 208V la-0 0 - 3 Cl 1/4 RISE - &S'C. OIL (GALS.) - 1 O(O WEIGHT (LEIS,) - Zg9-7 I 51/y Y s( 2 - e PHlSE NAIL T� ACES DATE UMWING NO- SNT_NN 3 07-20-qq PSK071(o010 2NF F'LF1 ml� NAME DRAWN �' APP D S RME -S RS 07/20/99 15 50 FAX 314 299 9072 PAUWELS TRANS a Z 006/006 ALL ITEMS MARKED " ARE INCLUDED FEM NO. DESCRIPTION ITEM NO. DESCRIP11ON HI h Voltage Bushings Raised Air Compartment Wells To For Ba -O-Net Fuse xi Load Break Inserts Replacement 20 1 N Load Break Integral 21 Jacking Provisions 1 I Livefront Porcelain 22 Coalinq Fins Low Voltage Bushings 25 Top Changer Studs A Tops -2.5% -5% -7 5% -10% 4 Hole Spade B lam +5% +2.5% -2 5% -5% 6 Hole Spade C Tos 6 Hole Supported J Spade 23 D"' Tops S Hole Supported J Spade 24 "Ho)(o Switch 10 Hole Supported J S ade Xn er,wl nK C0. r e �UCA- 2 12 Hole Su orted J S ade 25 Dudl Sensing 3 X Parkinq Stand 1 1 Current Sensing 4 Pressure Relief Valve 26 1 ICTC Plastic Drip Cu Provision For Liquid Level Ga. MDoar Holding Bars 120' Open 5 27 Liquid Level Gaucie Position Provision For Liquid Temp. Ga. Minternal Under Oil Current Temperature Gau a Limitina Fuses 6 28 n 7 §-Ljqutd Oil Fill Plug 29 Paint Munsell 0eS2.c Tn Oil Drain Plug 30 Additional Protective Coating Drain Plug And Sampler 31 High - Low Barrier --Oil OII Drain Valve 32 Stainless Steel Hinges 8 Oil Drain Valve And Sampler 33 All Bushin s Are External) 9 DQ Nameplate Clamped Ground Pads 34 Bolted Cover 10 2-Hole Ground Pads 35 Pressure Vac Gua e 11' Low Voltage Ground Strap 12, Provision For Lifting Padlock FacilityAnd Door Bolt A Pentahead Bolt B - $ 13 Hexhead Bolt D - 2_7 14 Low Voltage Door Handle 15 Removable Lower Front Sill E - 73 1 F - �I' I Base Arrangement For Rotting G _ !2. 16 In Two Directions H _ 4' 8 17, Transformer Tank -_ is Low Voltage Com artment Door 19 High Voltage Compartment Door I _ J - -735/6 K - to b 2. L - kVA- - 3oo HV. - IS2005rdY 76Z0 M - N - G LV 208Y 17-0 RISE - (oS�CG OIL (GALS.) - (al WEIGHT (LBS.) - 3(0(07 o- 4olz- Y - 101!2_ Z - 6Sl8 REF PHASE MA L TOLERANimCES � v DATE DPAWING NO SHr. NO RENSION LFMO01D 3 ®. 0'I-2m-49 RSK071(6010 29 0 RAN SFO RM EiRS orciuu. ,wcuuR NAME DRAWN BY RS APP D BT Q�1 FIRM NAME /^%S7lrri 1Jyj J 64- CITY OF FORT COLLINS BID PROPOSAL BID NO 5406 BID OPENING 2 00 p m lour clock) August 4, 1999 WE HEREBY ENTER OUR BID FOR THE CITY OF FORT COLLINS' REQUIREMENTS FOR TRANSFORMER, 150 KVA, 300 KVA PER THE BID INVITATION AND ANY REFERENCED SPECIFICATIONS QUANTITY DESCRIPTION* 15 Ea Transformer, 150 KVA pad -mounted compartmental -type, three phase distribution with separable insulated load break high -voltage connectors High voltage rating 13200 GRDY/7620 Low voltage rating 208Y/120 Serial number 015 to be in accordance with Specification #368-300- 015, Revision II $ 4620. '2Q Ea $ ca Total Delivery in weeks ARO 24 - 24, Mfr & Mfr # {uE�y�vo2 e�7-28�� The transformers being bid meet or exceed the specifications V_ Yes No If not, please list exceptions, (specifying paragraph reference number) on a separate sheet of paper and attach to your bid Guaranteed No Load Loss 277 Guaranteed Full Load Loss ///D Guaranteed Total Load Loss /387 Impedance (%) 2.2 Escalation is is not Z applicable for the transformers bid If escalation applies, the bidder shall indicate in his bid the specific items or materials subject to escalation, and shall give the method and indices to be used in computing the amount thereof Escalation occurring after the quoted delivery date will not be paid unless delays are the result of actions by the city Escalation occurring after acceptance if purchaser exercises the option to delay shipment after manufacturing is completed, will not be paid 3