HomeMy WebLinkAboutIMPORT AUTO SALES - Filed CS-COMMENT SHEETS -6QSelected Issues Report
C.ity=of I rart Collin
Date: 9/29/2008
IMPORT AUTO SALES, TOWING & STORAGE PDP - TYPE I
SELECTION CRITERIA: Status = All
ISSUES:
Department: Engineering Issue Contact: Randy Maizland
Topic: Engineering
Number:2 Created:10/30/2007 Pending
10/30/07] Deeds of dedication: ROW and easement deeds of dedication were submitted
without review fee payment. I have done a preliminary check of the easement documents
however, the legal descriptions will not be reviewed by our survey division until all fees have
been paid. The following dedications are needed for this project: 3 foot ROW dedication
submitted), 9 foot Utility Easement behind the ROW (nothing submitted), on -site Drainage
Easement.for the detention pond (nothing submitted), and an off -site Drainage & Utility
Easement (submitted). To cut'down on fees, you may combine the on -site & off -site
easement into one document if you wish since they are connected and can be described in
one legal description. Please submit 3 or 4 revised easement documents for review with the
appropriate review fees and County recording fees. Please see the red -line Check Prints
and Utility Plan comments attached for clarification.
Number:3 Created:10/30/2007 Pending
10/30/07] Site Plan - Please show all existing and proposed easements (on & off -site) on
the Site Plan drawing.
Number:4 Created:10/30/2007 Pending
10/30/07] Please show and label all existing and proposed easements by separate
document on the Utility Plan set, see redlines for clarification..
Number:5 Created:10/30/2007 Pending
10/30/07] Call out the new driveway and H.C. ramps with the LCUASS standard. Please
add the H.C. ramp standard to the Details on sheet 4.
Number:6 Created:10/30/2007 Pending
10/30./07] Please show any existing driveway curb cuts on the west side of Red Cedar to
verify that minimum standard driveway spacing will work. Submit a variance request for any
spacing less than 50 feet CL to CL. List on Note 48 of the General Notes if a variance is
requested.
Number:7 Created:10/30/2007 Pending
10/30/07] Please show and label a type II barricade at the new sidewalk terminus on the
south end.
Number: 8 Created:10/30/2007 Pending
Page 1
10/30/07] The drainage outfall to Conifer street should be through a standard LCUASS or
Stormwater approved curb chase drain. Since there is existing C&G on Conifer, a standard
chase drain can be constructed in the ultimate location for future sidewalk. Please show
and call out on the plans with adequate spot elevations. Add the appropriate detail on sheet
4.
Number:9 Created:10/30/2007 Pending
10/30/07] See redlines for any other minor comments related to drafting or labeling as well
as easement dedication options. We will need either a signed deed of dedication or letter of
intent from the owner of Lot 9 prior to scheduling a hearing. All other plan related issues can
be resolved with Final Compliance.
Department: Traffic Operations
Topic: Tra'Mc
Number: 16
11/12/07] No Issues. No Automotive TIS required.
Issue Contact: Ward Stanford
Created:11/12/2007 Pending
Page 2