HomeMy WebLinkAboutCOMPACTION TESTING - Filed CT-CONCRETE TEST - (11)Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 1021 Street Subgrade: Crusader St. - (west of Aria Way) SDMH I4, north side 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1022 Street Subgrade: Crusader St. - (west of Aria Way) SDMH I4, south side 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1023 Street Subgrade: Crusader St. - (west of Aria Way) SDMH I4.1, west side 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1024 Street Subgrade: Crusader St. - (west of Aria Way) SDMH I4.1, east side 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1025 Street Subgrade: Crusader St. - (west of Aria Way) SDMH I4.2, north side 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1026 Street Subgrade: Crusader St. - (west of Aria Way) SDMH I4.2, south side 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1027 Street Subgrade: Crusader St. - (west of Aria Way) SSMH 1.1, west side 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1028 Street Subgrade: Crusader St. - (west of Aria Way) SSMH 1.1, east side 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 1021 04/24/24 14 698C Granular 10.0 123.5 8.0 118.3 127.8 8 96 95 A 1022 04/24/24 14 698C Granular 10.0 123.5 8.8 117.6 127.9 8 95 95 A 1023 04/24/24 14 698C Granular 10.0 123.5 9.0 116.9 127.4 8 95 95 A 1024 04/24/24 14 698C Granular 10.0 123.5 8.5 119.0 129.1 8 96 95 A 1025 04/24/24 14 698C Granular 10.0 123.5 9.2 119.2 130.2 8 97 95 A 1026 04/24/24 14 698C Granular 10.0 123.5 9.9 117.0 128.6 8 95 95 A 1027 04/24/24 14 698C Granular 10.0 123.5 9.1 118.3 129.1 8 96 95 A 1028 04/24/24 14 698C Granular 10.0 123.5 11.1 118.6 131.8 8 96 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 1 of 13 Compaction Testing Test Method: ASTM D 6938 Report Date: 05/23/2024 Report #: SNG-000024 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 1029 Street Subgrade: Crusader St. - (west of Aria Way) SSMH 1.1-1, south side 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1030 Street Subgrade: Crusader St. - (west of Aria Way) SSMH 1.1-1, north side 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1031 Street Subgrade: Crusader St. - (west of Aria Way) SSMH 1.1-2, north side 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1032 Street Subgrade: Crusader St. - (west of Aria Way) SSMH 1.1-2, south side 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1033 Street Subgrade: Crusader St. - (west of Aria Way) SSMH 1.1-3, west side 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1034 Street Subgrade: Crusader St. - (west of Aria Way) SSMH 1.1-3, east side 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1035 Street Subgrade: Crusader St. - (west of Aria Way) SSMH 1.1-4, north side 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1036 Street Subgrade: Crusader St. - (west of Aria Way) SSMH 1.1-4, south side 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 1029 04/24/24 14 698C Granular 10.0 123.5 9.7 118.9 130.4 8 96 95 A 1030 04/24/24 14 698C Granular 10.0 123.5 8.7 118.6 128.9 8 96 95 A 1031 04/24/24 14 698C Granular 10.0 123.5 9.2 116.9 127.6 8 95 95 A 1032 04/24/24 14 698C Granular 10.0 123.5 9.3 117.9 128.9 8 95 95 A 1033 04/24/24 14 698C Granular 10.0 123.5 9.1 117.2 127.9 8 95 95 A 1034 04/24/24 14 698C Granular 10.0 123.5 8.8 117.7 128.0 8 95 95 A 1035 04/24/24 14 698C Granular 10.0 123.5 9.2 118.3 129.2 8 96 95 A 1036 04/24/24 14 698C Granular 10.0 123.5 10.4 117.0 129.2 8 95 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 2 of 13 Compaction Testing Test Method: ASTM D 6938 Report Date: 05/23/2024 Report #: SNG-000024 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 1037 Street Subgrade: Crusader St. - (west of Aria Way), westbound lane, intersection of Aria Way, center of lane 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1038 Street Subgrade: Crusader St. - (west of Aria Way), westbound lane, approximately station 125+75, along curb 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1039 Street Subgrade: Crusader St. - (west of Aria Way), westbound lane, approximately station 125+25, center of lane 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1040 Street Subgrade: Crusader St. - (west of Aria Way), westbound lane, approximately station 124+50, along curb 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1041 Street Subgrade: Crusader St. - (west of Aria Way), westbound lane, intersection of Roselyn Rd. - center of lane 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1042 Street Subgrade: Crusader St. - (west of Aria Way), westbound lane, approximately station 123+25 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1043 Street Subgrade: Crusader St. - (west of Aria Way), westbound lane, approximately station 122+25, center of lane 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1044 Street Subgrade: Crusader St. - (west of Aria Way), westbound lane, approximately station 121+50, along curb 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 1037 04/24/24 14 698C Granular 10.0 123.5 9.2 119.3 130.3 8 97 95 A 1038 04/24/24 14 698C Granular 10.0 123.5 8.7 120.6 131.1 8 98 95 A 1039 04/24/24 14 698C Granular 10.0 123.5 9.6 124.0 135.9 8 100 95 A 1040 04/24/24 14 698C Granular 10.0 123.5 8.7 118.8 129.1 8 96 95 A 1041 04/24/24 14 698C Granular 10.0 123.5 10.2 118.7 130.8 8 96 95 A 1042 04/24/24 14 698C Granular 10.0 123.5 9.3 118.1 129.1 8 96 95 A 1043 04/24/24 14 698C Granular 10.0 123.5 10.6 120.5 133.3 8 98 95 A 1044 04/24/24 14 698C Granular 10.0 123.5 11.6 117.3 130.9 8 95 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 3 of 13 Compaction Testing Test Method: ASTM D 6938 Report Date: 05/23/2024 Report #: SNG-000024 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 1045 Street Subgrade: Crusader St. - (west of Aria Way), westbound lane, approximately station 121+75, center of lane 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1046 Street Subgrade: Crusader St. - (west of Aria Way), eastbound lane, approximately station 1210+75, along curb 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1047 Street Subgrade: Crusader St. - (west of Aria Way), eastbound lane, approximately station 121+75, center of lane 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1048 Street Subgrade: Crusader St. - (west of Aria Way), eastbound lane, approximately station 122+50, along curb 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1049 Street Subgrade: Crusader St. - (west of Aria Way), eastbound lane, approximately station 123+00, center of lane 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1050 Street Subgrade: Crusader St. - (west of Aria Way), eastbound lane, approximately station 124+00, along curb 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1051 Street Subgrade: Crusader St. - (west of Aria Way), eastbound lane, approximately station 124+75, center of lane 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1052 Street Subgrade: Crusader St. - (west of Aria Way), eastbound lane, approximately station 125+50, along curb 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 1045 04/24/24 14 698C Granular 10.0 123.5 8.6 118.8 129.0 8 96 95 A 1046 04/24/24 14 698C Granular 10.0 123.5 11.4 117.1 130.5 8 95 95 A 1047 04/24/24 14 698C Granular 10.0 123.5 10.2 118.8 130.9 8 96 95 A 1048 04/24/24 14 698C Granular 10.0 123.5 11.7 117.5 131.3 8 95 95 A 1049 04/24/24 14 698C Granular 10.0 123.5 8.6 118.7 128.9 8 96 95 A 1050 04/24/24 14 698C Granular 10.0 123.5 8.6 120.3 130.7 8 97 95 A 1051 04/24/24 14 698C Granular 10.0 123.5 9.3 117.5 128.4 8 95 95 A 1052 04/24/24 14 698C Granular 10.0 123.5 8.1 118.1 127.7 8 96 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 4 of 13 Compaction Testing Test Method: ASTM D 6938 Report Date: 05/23/2024 Report #: SNG-000024 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 1053 Street Subgrade: Crusader St. - (west of Aria Way), eastbound lane, intersection of Aria Way, center of lane 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1054 Street Subgrade: Aria Way - (south of Crusader St.), southbound lane, approximately station 42+75, along curb 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1055 Street Subgrade: Aria Way - (south of Crusader St.), southbound lane, approximately station 43+80, center of lane 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1056 Street Subgrade: Aria Way - (south of Crusader St.), northbound lane, approximately station 44+50, along curb 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1057 Street Subgrade: Aria Way - (south of Crusader St.), northbound lane, approximately station 43+25, center of lane 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1058 Street Subgrade: Aria Way - (south of Crusader St.), SDMH J4.1, north side 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1059 Street Subgrade: Aria Way - (south of Crusader St.), SDMH J4.1, south side 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1060 Street Sub-Excavation and Backfill: Street repair, Greenfields Drive, Station 34+80, west curb 1.5 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 1060: Curb, adjacent street and underlying subgrade was removed to fix frost heave in subgrade Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 1053 04/24/24 14 698C Granular 10.0 123.5 10.2 118.2 130.3 8 96 95 A 1054 04/24/24 14 698C Granular 10.0 123.5 8.4 118.1 128.0 8 96 95 A 1055 04/24/24 14 698C Granular 10.0 123.5 10.3 121.0 133.5 8 98 95 A 1056 04/24/24 14 698C Granular 10.0 123.5 11.4 118.2 131.7 8 96 95 A 1057 04/24/24 14 698C Granular 10.0 123.5 11.0 120.8 134.1 8 98 95 A 1058 04/24/24 14 698C Granular 10.0 123.5 12.0 118.6 132.8 8 96 95 A 1059 04/24/24 14 698C Granular 10.0 123.5 11.9 117.5 131.5 8 95 95 A 1060 05/02/24 9 698A Granular 14.0 117.0 15.3 113.5 130.9 8 97 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 5 of 13 Compaction Testing Test Method: ASTM D 6938 Report Date: 05/23/2024 Report #: SNG-000024 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 1061 Street Sub-Excavation and Backfill: Street repair, Greenfields Drive, Station 34+60, west curb 1.5 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1062 Aggregate Base Course: Curb and Gutter, Crusader Street, Station 128+50, left side of street 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1063 Aggregate Base Course: Curb and Gutter, Flourish Lane, Station 124+50, right side of street 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1064 Aggregate Base Course: Curb and Gutter, Flourish Lane, Station 122+00, right side of street 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1065 Aggregate Base Course: Curb and Gutter, Flourish Lane, Station 120+50, right side of street 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1066 Aggregate Base Course: Curb and Gutter, Comet Street, Station 118+50, right side of street 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1067 Aggregate Base Course: Curb and Gutter, Crusader Street, Station 129+00, right side of street 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1068 Aggregate Base Course: Curb and Gutter, Flourish Lane, Station 124+50, left side of street 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 1061 05/02/24 9 698A Granular 14.0 117.0 15.7 113.8 131.7 8 97 95 A 1062 05/02/24 15 698C Granular 7.5 129.0 6.7 128.5 137.1 6 100 95 A 1063 05/02/24 15 698C Granular 7.5 129.0 5.7 127.4 134.6 6 99 95 A 1064 05/02/24 15 698C Granular 7.5 129.0 5.6 127.1 134.2 6 99 95 A 1065 05/02/24 15 698C Granular 7.5 129.0 6.2 129.4 137.4 6 100 95 A 1066 05/02/24 15 698C Granular 7.5 129.0 5.8 125.2 132.5 6 97 95 A 1067 05/03/24 15 698C Granular 7.5 129.0 6.6 132.5 141.2 6 103 95 A 1068 05/03/24 15 698C Granular 7.5 129.0 6.6 131.6 140.3 6 102 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 6 of 13 Compaction Testing Test Method: ASTM D 6938 Report Date: 05/23/2024 Report #: SNG-000024 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 1069 Aggregate Base Course: Curb and Gutter, Flourish Lane, Station 122+50, left side of street 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1070 Aggregate Base Course: Curb and Gutter, Flourish Lane, Station 121+00, left side of street 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1071 Aggregate Base Course: Curb and Gutter, Comet Street, Station 119+00, left side of street 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1072 Curb and Gutter Subgrade: Crusader Street, Station 129+00, south side of street, machine pour 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1073 Curb and Gutter Subgrade: Comet Street, Station 117+30, north side of street, hand pour 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1074 Curb and Gutter Subgrade: Comet Street, Station 117+30, south side of street, hand pour 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1075 Curb and Gutter Subgrade: Comet Street and Flourish Lane, radius on southwest corner of streets 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1076 Curb and Gutter Subgrade: Crusader Street and Flourish Lane, radius on northwest corner of streets 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 1069 05/03/24 15 698C Granular 7.5 129.0 6.5 127.3 135.6 6 99 95 A 1070 05/03/24 15 698C Granular 7.5 129.0 6.3 130.1 138.3 6 101 95 A 1071 05/03/24 15 698C Granular 7.5 129.0 5.8 131.3 138.9 6 102 95 A 1072 05/06/24 15 698C Granular 7.5 129.0 5.6 127.9 135.1 6 99 95 A 1073 05/06/24 15 698C Granular 7.5 129.0 6.6 123.1 131.2 6 95 95 A 1074 05/06/24 15 698C Granular 7.5 129.0 5.7 122.4 129.4 6 95 95 A 1075 05/06/24 15 698C Granular 7.5 129.0 5.8 123.4 130.6 6 96 95 A 1076 05/06/24 15 698C Granular 7.5 129.0 6.8 126.6 135.2 6 98 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 7 of 13 Compaction Testing Test Method: ASTM D 6938 Report Date: 05/23/2024 Report #: SNG-000024 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 1077 Curb and Gutter Subgrade: Crusader Street and Aria Way, radius on northeast corner of streets 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1078 Aggregate Base Course: Curb & Gutter, Tract J alleys, west side of Lot 14, Block 6 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1079 Aggregate Base Course: Curb & Gutter, Tract J, south side of cross pan southwest of Lot 25, Block 6 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1080 Aggregate Base Course: Curb & Gutter, Tract J, north side of cross pan southwest of Lot 25, Block 6 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1081 Aggregate Base Course: Curb & Gutter, Tract J, south side of cross pan southeast of Lot 30, Block 6 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1082 Aggregate Base Course: Curb & Gutter, Tract J, north side of cross pan southeast of Lot 30, Block 6 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1083 Aggregate Base Course: Curb & Gutter, Tract J alleys, east side of Lot 9, Block 6 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1084 Aggregate Base Course: Curb & Gutter, Tract J alleys, north side of Lot 12, Block 6 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 1077 05/06/24 15 698C Granular 7.5 129.0 6.4 124.1 132.0 6 96 95 A 1078 05/07/24 15 698C Granular 7.5 129.0 5.9 130.4 138.1 6 101 95 A 1079 05/07/24 15 698C Granular 7.5 129.0 6.0 124.8 132.3 6 97 95 A 1080 05/07/24 15 698C Granular 7.5 129.0 5.5 123.6 130.4 6 96 95 A 1081 05/07/24 15 698C Granular 7.5 129.0 6.3 122.4 130.1 6 95 95 A 1082 05/07/24 15 698C Granular 7.5 129.0 5.8 123.2 130.3 6 96 95 A 1083 05/07/24 15 698C Granular 7.5 129.0 5.6 129.0 136.2 6 100 95 A 1084 05/07/24 15 698C Granular 7.5 129.0 6.1 129.1 137.0 6 100 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 8 of 13 Compaction Testing Test Method: ASTM D 6938 Report Date: 05/23/2024 Report #: SNG-000024 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 1085 Sidewalk Subgrade: Parkland Street, east side of cul-de-sac 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1086 Sidewalk Subgrade: Parkland Street, northeast side of cul-de-sac 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1087 Aggregate Base Course: Southeast corner of Aria Way and Crusader Street 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1088 Aggregate Base Course: Curb and Gutter, Aria Way, Station 44+00, west side 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1089 Aggregate Base Course: Curb and Gutter, Crusader Street, Station 126+40, north side 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1090 Aggregate Base Course: Curb and Gutter, Crusader Street, Station 123+50, north side 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1091 Aggregate Base Course: Curb and Gutter, Crusader Street, Station 124+00, north side 0.0 below grade(feet)XPLORER / 3500 / 3383 / 01/24/2018 Braun, Frederick 1092 Aggregate Base Course: Tract J/ Block 6, west alley, adjacent to Lot 14 Block 6 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 1085 05/08/24 6 698C Granular 7.0 131.5 8.2 127.0 137.4 8 97 95 A 1086 05/08/24 6 698C Granular 7.0 131.5 8.5 126.1 136.8 8 96 95 A 1087 05/08/24 15 698C Granular 7.5 129.0 5.9 128.3 135.9 6 99 95 A 1088 05/08/24 15 698C Granular 7.5 129.0 6.5 131.7 140.2 6 102 95 A 1089 05/09/24 15 698C Granular 7.5 129.0 7.6 124.4 133.9 6 96 95 A 1090 05/09/24 15 698C Granular 7.5 129.0 5.8 128.3 135.7 6 99 95 A 1091 05/09/24 15 698C Granular 7.5 129.0 6.1 125.7 133.4 6 97 95 A 1092 04/30/24 15 698C Granular 7.5 129.0 6.9 131.4 140.5 4 102 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 9 of 13 Compaction Testing Test Method: ASTM D 6938 Report Date: 05/23/2024 Report #: SNG-000024 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 1093 Aggregate Base Course: Tract J/ Block 6, west alley, adjacent to Lot 25 Block 6 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1094 Aggregate Base Course: Tract J/ Block 6, center of west parking 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1095 Aggregate Base Course: Tract J/ Block 6, center alley, adjacent to Lot 26 Block 6 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1096 Aggregate Base Course: Tract J/ Block 6, center alley, adjacent to Lot 30 Block 6 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1097 Aggregate Base Course: Tract J/ Block 6, east alley, adjacent to Lot 9 Block 6 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1098 Aggregate Base Course: Tract J/ Block 6, east alley, adjacent to Lot 30 Block 6 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1099 Aggregate Base Course: Tract J/ Block 6, center of east parking lot 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1100 Aggregate Base Course: Aria Way, curb and gutter, southbound lane, approximately station 42+75 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 1093 04/30/24 15 698C Granular 7.5 129.0 5.8 131.3 138.9 4 102 95 A 1094 04/30/24 15 698C Granular 7.5 129.0 6.2 132.0 140.2 4 102 95 A 1095 04/30/24 15 698C Granular 7.5 129.0 7.4 131.0 140.7 4 102 95 A 1096 04/30/24 15 698C Granular 7.5 129.0 6.5 130.2 138.6 4 101 95 A 1097 04/30/24 15 698C Granular 7.5 129.0 6.3 129.4 137.6 10 100 95 A 1098 04/30/24 15 698C Granular 7.5 129.0 6.8 131.6 140.5 10 102 95 A 1099 04/30/24 15 698C Granular 7.5 129.0 6.2 130.7 138.8 10 101 95 A 1100 05/01/24 15 698C Granular 7.5 129.0 5.9 132.2 140.0 4 102 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 10 of 13 Compaction Testing Test Method: ASTM D 6938 Report Date: 05/23/2024 Report #: SNG-000024 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 1101 Aggregate Base Course: Aria Way, curb and gutter, southbound lane, approximately station 43+90 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1102 Aggregate Base Course: Aria Way, curb and gutter, northbound lane, approximately station 44+45 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1103 Aggregate Base Course: Aria Way, curb and gutter, northbound lane, approximately station 43+25 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1104 Aggregate Base Course: Crusader St. - curb and gutter, eastbound lane, approximately station 125+75 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1105 Aggregate Base Course: Crusader St. - curb and gutter, eastbound lane, approximately station 123+75 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1106 Aggregate Base Course: Crusader St. - curb and gutter, eastbound lane, approximately station 123+75 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1107 Aggregate Base Course: Crusader St. - curb and gutter, eastbound lane, approximately station 121+75 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1108 Aggregate Base Course: Crusader St. - curb and gutter, eastbound lane, approximately station 121+00 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 1101 05/01/24 15 698C Granular 7.5 129.0 5.5 125.6 132.5 4 97 95 A 1102 05/01/24 15 698C Granular 7.5 129.0 6.1 122.2 129.6 4 95 95 A 1103 05/01/24 15 698C Granular 7.5 129.0 7.2 131.4 140.9 4 102 95 A 1104 05/01/24 15 698C Granular 7.5 129.0 8.1 127.9 138.3 4 99 95 A 1105 05/01/24 15 698C Granular 7.5 129.0 7.3 131.0 140.5 4 102 95 A 1106 05/01/24 15 698C Granular 7.5 129.0 7.3 131.0 140.5 4 102 95 A 1107 05/01/24 15 698C Granular 7.5 129.0 5.9 127.2 134.7 4 99 95 A 1108 05/01/24 15 698C Granular 7.5 129.0 5.7 130.6 138.0 4 101 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 11 of 13 Compaction Testing Test Method: ASTM D 6938 Report Date: 05/23/2024 Report #: SNG-000024 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 1109 Aggregate Base Course: Crusader St. - curb and gutter, westbound lane, approximately station 120+75 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1110 Aggregate Base Course: Crusader St. - curb and gutter, westbound lane, approximately station 122+75 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1111 Aggregate Base Course: Crusader St. - curb and gutter, westbound lane, approximately station 124+50 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1112 Aggregate Base Course: Crusader St. - curb and gutter, westbound lane, approximately station 125+75 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1113 Street Subgrade: Flourish Ln. - in front of inlet S-205 (east inlet)0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1114 Street Subgrade: Flourish Ln. - in front of inlet S-202 (west inlet)0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1115 Street Subgrade: Crusader St. (east of Aria Way), in front of inlet S-211 (south inlet)0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1116 Street Subgrade: Crusader St. (east of Aria Way), in front of inlet S-210 (north inlet)0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 1109 05/01/24 15 698C Granular 7.5 129.0 7.5 126.5 136.0 4 98 95 A 1110 05/01/24 15 698C Granular 7.5 129.0 7.2 126.5 135.6 4 98 95 A 1111 05/01/24 15 698C Granular 7.5 129.0 6.6 124.7 132.9 4 97 95 A 1112 05/01/24 15 698C Granular 7.5 129.0 6.6 125.1 133.3 4 97 95 A 1113 04/26/24 50 Cohesive 13.5 113.5 14.8 110.1 126.4 8 97 95 A 1114 04/26/24 50 Cohesive 13.5 113.5 14.6 110.0 126.1 8 97 95 A 1115 04/26/24 50 Cohesive 13.5 113.5 14.8 109.3 125.5 8 96 95 A 1116 04/26/24 50 Cohesive 13.5 113.5 14.5 113.6 130.1 8 100 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 12 of 13 Compaction Testing Test Method: ASTM D 6938 Report Date: 05/23/2024 Report #: SNG-000024 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 1117 Street Subgrade: Crusader St. (west of Aria Way), in front of inlet I4.1-A.1(north inlet)0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1118 Street Subgrade: Crusader St. (west of Aria Way), in front of inlet I4.1-A (south inlet)0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1119 Street Subgrade: Aria Way, in front of inlet J4.1-A.1 (west inlet)0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 1120 Street Subgrade: Aria Way, in front of inlet J4.2 (east inlet)0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 1117 04/26/24 50 Cohesive 13.5 113.5 14.5 110.7 126.7 8 98 95 A 1118 04/26/24 50 Cohesive 13.5 113.5 14.6 109.1 125.0 8 96 95 A 1119 04/26/24 50 Cohesive 13.5 113.5 14.7 111.3 127.7 8 98 95 A 1120 04/26/24 50 Cohesive 13.5 113.5 14.7 108.5 124.4 8 96 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 13 of 13 Compaction Testing Test Method: ASTM D 6938 Report Date: 05/23/2024 Report #: SNG-000024 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins