Loading...
HomeMy WebLinkAboutCOMPACTION TESTING - Filed CT-CONCRETE TEST - (7)Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 705 Sidewalk Subgrade: West side of Greenfields Dr. - south of Donella Dr. - approximately station 50+50 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 706 Sidewalk Subgrade: West side of Greenfields Dr. - south of Donella Dr. - approximately station 52+50 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 707 Sidewalk Subgrade: West side of Greenfields Dr. - south of Donella Dr. - approximately station 54+50 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 708 Sidewalk Subgrade: West side of Greenfields Dr. - south of Donella Dr. - approximately station 56+50 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 709 Sidewalk Subgrade: South side of Sykes Dr. - tie in on the southwest corner of Sykes Dr. and Greenfields Dr. - approximately 15 feet west of ramp 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 710 Sidewalk Subgrade: South side of Sykes Dr. - tie in on the southwest corner of Sykes Dr. and Greenfields Dr. - approximately 40 feet west of ramp 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 705 02/14/24 7 698B Granular 9.5 126.0 10.1 125.4 138.1 10 100 95 A 706 02/14/24 7 698B Granular 9.5 126.0 8.1 127.3 137.6 10 101 95 A 707 02/14/24 7 698B Granular 9.5 126.0 11.3 122.3 136.1 10 97 95 A 708 02/14/24 7 698B Granular 9.5 126.0 11.0 119.5 132.6 10 95 95 A 709 02/14/24 4 698B Granular 12.5 118.0 10.7 117.0 129.5 10 99 95 A 710 02/14/24 4 698B Granular 12.5 118.0 11.3 120.0 133.5 10 102 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 1 of 1 Compaction Testing Test Method: ASTM D 6938 Report Date: 02/16/2024 Report #: SNG-000019 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins