HomeMy WebLinkAboutBITUMINOUS DENSITY - Filed CT-CONCRETE TEST -Test Results Test # Retest Of Test Date Test Location Material Mix Design Thickness (in) Max Density (pcf) Max Density Source In Place Density (pcf) Probe Depth (in) Percent Comp. Min/Max Comp. (%)Remark Gauge SN Technician 201 12/05/23 Asphalt Placement: Greenfields Dr. - southbound lane, approximately 600 feet south of Sykes Dr. - 11 feet from centerline Base Lift 1 3 155.8 12-5-23 Mix 5493 Taft / Rice 143.8 Backscatter 92 92 / 96 A 3812 Matte, Ryan 202 12/05/23 Asphalt Placement: Greenfields Dr. - southbound lane, approximately 800 feet south of Sykes Dr. - 8 feet from curb Base Lift 1 3 155.8 12-5-23 Mix 5493 Taft / Rice 144.0 Backscatter 92 92 / 96 A 3812 Matte, Ryan 203 12/05/23 Asphalt Placement: Greenfields Dr. - southbound lane, approximately 1000 feet south of Sykes Dr. - 4 feet from centerline Base Lift 1 3 155.8 12-5-23 Mix 5493 Taft / Rice 144.4 Backscatter 93 92 / 96 A 3812 Matte, Ryan 204 12/05/23 Asphalt Placement: Greenfields Dr. - southbound lane, approximately 1115 feet south of Sykes Dr. - center of lane Base Lift 1 3 155.8 12-5-23 Mix 5493 Taft / Rice 144.1 Backscatter 92 92 / 96 A 3812 Matte, Ryan 205 12/05/23 Asphalt Placement: Greenfields Dr. - northbound lane, approximately 50 feet south of Sykes Dr. - 10 feet from centerline Base Lift 1 3 155.8 12-5-23 Mix 5493 Taft / Rice 144.1 Backscatter 92 92 / 96 A 3812 Matte, Ryan 206 12/05/23 Asphalt Placement: Greenfields Dr. - northbound lane, approximately 250 feet south of Sykes Dr. - 4 feet from curb Base Lift 1 3 155.8 12-5-23 Mix 5493 Taft / Rice 145.6 Backscatter 93 92 / 96 A 3812 Matte, Ryan This report presents opinions formed as a result of our observations of asphalt placement and the test results shown above. Test data are not the sole basis for opinions whether the asphalt meets project specifications. The contractor is responsible to apply necessary compaction effort to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 1 of 5 Bituminous Density Test Method: ASTM D2950 Report Date: 02/16/2024 Report #: BNG-000003 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-355 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Results Test # Retest Of Test Date Test Location Material Mix Design Thickness (in) Max Density (pcf) Max Density Source In Place Density (pcf) Probe Depth (in) Percent Comp. Min/Max Comp. (%)Remark Gauge SN Technician 207 12/05/23 Asphalt Placement: Greenfields Dr. - northbound lane, approximately 450 feet south of Sykes Dr. - 4 feet from ccenterline Base Lift 1 3 155.8 12-5-23 Mix 5493 Taft / Rice 145.0 Backscatter 93 92 / 96 A 3812 Matte, Ryan 208 12/05/23 Asphalt Placement: Greenfields Dr. - northbound lane, approximately 650 feet south of Sykes Dr. - 8 feet from curb Base Lift 1 3 155.8 12-5-23 Mix 5493 Taft / Rice 143.8 Backscatter 92 92 / 96 A 3812 Matte, Ryan 209 12/05/23 Asphalt Placement: Greenfields Dr. - northbound lane, approximately 850 feet south of Sykes Dr. - 7 feet from centerline Base Lift 1 3 155.8 12-5-23 Mix 5493 Taft / Rice 144.8 Backscatter 93 92 / 96 A 3812 Matte, Ryan 210 12/05/23 Asphalt Placement: Greenfields Dr. - northbound lane, approximately 1050 feet south of Sykes Dr. - 6 feet from curb Base Lift 1 3 155.8 12-5-23 Mix 5493 Taft / Rice 143.0 Backscatter 92 92 / 96 A 3812 Matte, Ryan 211 12/05/23 Asphalt Placement: Greenfields Dr. - northbound lane, approximately 1120 feet south of Sykes Dr. - 2 feet from centerline Base Lift 1 3 155.8 12-5-23 Mix 5493 Taft / Rice 143.8 Backscatter 92 92 / 96 A 3812 Matte, Ryan 212 12/07/23 Asphalt Placement: Greenfields Dr. - southbound lane, outside lane, approximately 100 feet south of Sykes Dr. - 6 feet from curb Base Lift 2 2 154.4 12-7-23 Mix 5493 Taft / Rice 143.6 Backscatter 93 92 / 96 A 3812 Matte, Ryan This report presents opinions formed as a result of our observations of asphalt placement and the test results shown above. Test data are not the sole basis for opinions whether the asphalt meets project specifications. The contractor is responsible to apply necessary compaction effort to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 2 of 5 Bituminous Density Test Method: ASTM D2950 Report Date: 02/16/2024 Report #: BNG-000003 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-355 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Results Test # Retest Of Test Date Test Location Material Mix Design Thickness (in) Max Density (pcf) Max Density Source In Place Density (pcf) Probe Depth (in) Percent Comp. Min/Max Comp. (%)Remark Gauge SN Technician 213 12/07/23 Asphalt Placement: Greenfields Dr. - southbound lane, inside lane, approximately 300 feet south of Sykes Dr. - 3 feet from centerline Base Lift 2 2 154.4 12-7-23 Mix 5493 Taft / Rice 142.6 Backscatter 92 92 / 96 A 3812 Matte, Ryan 214 12/07/23 Asphalt Placement: Greenfields Dr. - southbound lane, outside lane, approximately 500 feet south of Sykes Dr. - 4 feet from curb Base Lift 2 2 154.4 12-7-23 Mix 5493 Taft / Rice 143.5 Backscatter 93 92 / 96 A 3812 Matte, Ryan 215 12/07/23 Asphalt Placement: Greenfields Dr. - southbound lane, inside lane, approximately 700 feet south of Sykes Dr. - 9 feet from centerline Base Lift 2 2 154.4 12-7-23 Mix 5493 Taft / Rice 143.8 Backscatter 93 92 / 96 A 3812 Matte, Ryan 216 12/07/23 Asphalt Placement: Greenfields Dr. - southbound lane, outside lane, approximately 900 feet south of Sykes Dr. - 7 feet from curb Base Lift 2 2 154.4 12-7-23 Mix 5493 Taft / Rice 142.9 Backscatter 93 92 / 96 A 3812 Matte, Ryan 217 12/07/23 Asphalt Placement: Greenfields Dr. - southbound lane, inside lane, approximately 1100 feet south of Sykes Dr. - 5 feet from centerline Base Lift 2 2 154.4 12-7-23 Mix 5493 Taft / Rice 142.3 Backscatter 92 92 / 96 A 3812 Matte, Ryan 218 12/07/23 Asphalt Placement: Greenfields Dr. - northbound lane, outside lane, intersection of Sykes Dr. - 4 feet from curb Base Lift 2 2 154.4 12-7-23 Mix 5493 Taft / Rice 143.5 Backscatter 93 92 / 96 A 3812 Matte, Ryan This report presents opinions formed as a result of our observations of asphalt placement and the test results shown above. Test data are not the sole basis for opinions whether the asphalt meets project specifications. The contractor is responsible to apply necessary compaction effort to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 3 of 5 Bituminous Density Test Method: ASTM D2950 Report Date: 02/16/2024 Report #: BNG-000003 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-355 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Results Test # Retest Of Test Date Test Location Material Mix Design Thickness (in) Max Density (pcf) Max Density Source In Place Density (pcf) Probe Depth (in) Percent Comp. Min/Max Comp. (%)Remark Gauge SN Technician 219 12/07/23 Asphalt Placement: Greenfields Dr. - northbound lane, inside lane, approximately 200 feet south of Sykes Dr. - 3 feet from centerline Base Lift 2 2 154.4 12-7-23 Mix 5493 Taft / Rice 143.0 Backscatter 93 92 / 96 A 3812 Matte, Ryan 220 12/07/23 Asphalt Placement: Greenfields Dr. - northbound lane, outside lane, approximately 400 feet south of Sykes Dr. - 8 feet from curb Base Lift 2 2 154.4 12-7-23 Mix 5493 Taft / Rice 143.3 Backscatter 93 92 / 96 A 3812 Matte, Ryan 221 12/07/23 Asphalt Placement: Greenfields Dr. - northbound lane, inside lane, approximately 600 feet south of Sykes Dr. - 6 feet from centerline Base Lift 2 2 154.4 12-7-23 Mix 5493 Taft / Rice 142.6 Backscatter 92 92 / 96 A 3812 Matte, Ryan 222 12/07/23 Asphalt Placement: Greenfields Dr. - northbound lane, outside lane, approximately 800 feet south of Sykes Dr. - 2 feet from curb Base Lift 2 2 154.4 12-7-23 Mix 5493 Taft / Rice 143.0 Backscatter 93 92 / 96 A 3812 Matte, Ryan 223 12/07/23 Asphalt Placement: Greenfields Dr. - northbound lane, inside lane, approximately 1000 feet south of Sykes Dr. - 5 feet from centerline Base Lift 2 2 154.4 12-7-23 Mix 5493 Taft / Rice 143.1 Backscatter 93 92 / 96 A 3812 Matte, Ryan This report presents opinions formed as a result of our observations of asphalt placement and the test results shown above. Test data are not the sole basis for opinions whether the asphalt meets project specifications. The contractor is responsible to apply necessary compaction effort to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 4 of 5 Bituminous Density Test Method: ASTM D2950 Report Date: 02/16/2024 Report #: BNG-000003 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-355 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins Test Results Test # Retest Of Test Date Test Location Material Mix Design Thickness (in) Max Density (pcf) Max Density Source In Place Density (pcf) Probe Depth (in) Percent Comp. Min/Max Comp. (%)Remark Gauge SN Technician 224 12/07/23 Asphalt Placement: Greenfields Dr. - northbound lane, outside lane, approximately 1115 feet south of Sykes Dr. - 6 feet from curb Base Lift 2 2 154.4 12-7-23 Mix 5493 Taft / Rice 143.5 Backscatter 93 92 / 96 A 3812 Matte, Ryan Gauge Information Gauge SN Make Model Density Count Moisture Count Standard Count Date Last Calibration Date Last Calibrated By 3812 XPLORER 3500 2446 702 12/05/23 07/18/19 Instrotek 3812 XPLORER 3500 2424 695 12/07/23 07/18/19 Instrotek Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter" This report presents opinions formed as a result of our observations of asphalt placement and the test results shown above. Test data are not the sole basis for opinions whether the asphalt meets project specifications. The contractor is responsible to apply necessary compaction effort to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 5 of 5 Bituminous Density Test Method: ASTM D2950 Report Date: 02/16/2024 Report #: BNG-000003 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-355 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins