HomeMy WebLinkAboutCOMPACTION TESTING - Filed CT-CONCRETE TEST - (4)Test Information
Test #Test Location Elevation Reference
Gauge
Make / Model / SN / Calibrated Field Technician
701 Sidewalk Subgrade: North side of Sykes Dr. - center of the ramp on the northwest
corner of Sykes Dr. and Greenfields Dr.
0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan
702 Sidewalk Subgrade: North side of Sykes Dr. - approximately 20 feet west of the ramp
on northwest corner of Sykes Dr. and Greenfields Dr.
0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan
703 Sidewalk Subgrade: North side of Sykes Dr. - center of the ramp on the northeast
corner of Sykes Dr. and Aria Way
0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan
704 Sidewalk Subgrade: West side of Greenfields Dr. - south of Donella Dr. -
approximately station 51+50
0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan
Remarks
A: Test results comply with specifications.
Comments
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
Test Results
Test #
Retest
Of Test Date Proctor ID Method
Soil
Classification
Optimum
Moisture
(%)
Maximum
Dry
Density (pcf)
In Place
Moisture
(%)
In Place
Dry
Density
(pcf)
In Place
Wet
Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min Comp.
(%)Remark
701 02/13/24 4 698B Granular 12.5 118.0 11.3 113.6 126.4 10 96 95 A
702 02/13/24 4 698B Granular 12.5 118.0 12.0 112.1 125.6 10 95 95 A
703 02/12/24 4 698B Granular 12.5 118.0 11.0 116.2 129.0 10 98 95 A
704 02/13/24 7 698B Granular 9.5 126.0 9.9 119.1 130.9 10 95 95 A
This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for
opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project
specifications. Our test results, observations and opinions do not constitute acceptance of the work.
Page 1 of 1
Compaction Testing
Test Method: ASTM D 6938
Report Date: 02/16/2024
Report #: SNG-000018
Client:
Hartford Homes Construction
Timnath, CO 80547
4801 Goodman St
Project:
Bloom Filing 1
FC07733.001F-340
400 North Link Lane
Fort Collins, CO 80524
Phone: 970-206-9455
Fort Collins