Loading...
HomeMy WebLinkAboutCOMPRESSIVE STRENGTH OF CONCRETE - Filed CSS-COMPRESSIVE STRENGTH SUMMARY - (45)Specimen Number Test Age Days Test Date Field / Lab Cure Days Average Cylinder Diameter (in) Cylinder Area (in²) Max Load (lbs) Strength (psi) Fracture Type Break Remark Capping Method 203-1 7 02/01/24 1 / 6 4.00 12.57 51,950 4,130 3 N Test Age Average Strengths (psi): 7 Day - 4130 Tested By: Craig Ellis (1) Checked In : 01/26/2024 (1) Capping Methods N: Unbonded Caps (ASTM C1231) Set #:203 Specimen Size:4" X 8" Specimens In Set:5 Truck / Ticket #:1907 / 21094237 Contractor:Front Range Concrete Technician:McWhorter, Seth Cast By:McWhorter, Seth Date Cast:01/25/24 Sampled From:Truck Placement Method: Sample Details Batched:10:30 MST Sampled:11:10 MST Cast:11:25 MST Truck Empty: Placement Time: Placement Location:Sidewalk Location Details:Sidewalk ramp on south side of Conquest St, 100ft west of Whisperwind Ln Sample Location / Notes:Mix 45262 Batch Log Strength:4500 (psi) Specifications Supplier:SRM Concrete On-Site Admixtures: None Location Field Measurements Plastic Unit Weight:140.0 (lb/ft³) Air Content:6.4 Load Volume:6.25 (yd³) Weather:Slump (in):5 Air Temperature (F):45 Concrete Temp (F):65 Lab Test Results Testing Lab: Fort Collins, 400 North Link Lane, Fort Collins, CO, 80525 General Remarks 203-1: Reviewed by CE Test results relate only to the sample tested. Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064). This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc. Page 1 of 1 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-365 Compressive Strength of Concrete Test Method: ASTM C 39 Sample: 125627 Report #: CC-000712 Fort Collins 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Report Date: 02/02/2024