HomeMy WebLinkAboutCOMPACTION TEST - Filed P-PERMITS - (3)Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 667 Sidewalk Subgrade: South side of Conquest St. - adjacent to greenspace across from Lot 19 Block 2 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 668 Sidewalk Subgrade: South side of Conquest St. - ramp on the southwest corner of Aria Way and Conquest St. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 669 Driveway Apron Subgrade: South side of Conquest St. - driveway apron for alley, adjacent to Lot 22 Block 6 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 670 Sidewalk Subgrade: South side of Conquest St. - sidewalk ramp, west end of Conquest St. - across from Lot 19 Block 2 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan 671 Sidewalk Subgrade: North side of Sykes Dr. - approximately 50 feet east of Delozier Rd. 0.0 Below final grade (feet)XPLORER / 3500 / 3812 / 07/18/2019 Matte, Ryan Remarks A: Test results comply with specifications. Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 667 01/23/24 4 698B Granular 12.5 118.0 10.9 117.1 129.9 12 99 95 A 668 01/23/24 7 698B Granular 9.5 126.0 8.8 121.1 131.8 12 96 95 A 669 01/23/24 4 698B Granular 12.5 118.0 10.6 112.7 124.6 12 96 95 A 670 01/23/24 4 698B Granular 12.5 118.0 10.9 111.6 123.8 12 95 95 A 671 01/23/24 4 698B Granular 12.5 118.0 11.1 114.0 126.7 12 97 95 A This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications. Our test results, observations and opinions do not constitute acceptance of the work. Page 1 of 1 Compaction Testing Test Method: ASTM D 6938 Report Date: 01/29/2024 Report #: SNG-000015 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-340 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Fort Collins