Loading...
HomeMy WebLinkAboutCOMPRESSIVE STRENGTH OF CONCRETE - Filed CSS-COMPRESSIVE STRENGTH SUMMARY - (29)Specimen Number Test Age Days Test Date Field / Lab Cure Days Average Cylinder Diameter (in) Cylinder Area (in²) Max Load (lbs) Strength (psi) Fracture Type Break Remark Capping Method 180-5 56 01/24/24 1 / 55 4.00 12.57 71,480 5,690 3 C4 N Test Age Average Strengths (psi): 56 Day - 5690 C4: Strength is greater than or equal to f'c. Tested By: Craig Ellis (5) Checked In : 11/30/2023 (5) Capping Methods N: Unbonded Caps (ASTM C1231) Set #:180 Specimen Size:4" X 8" Specimens In Set:5 Truck / Ticket #:2028 / 21093352 Contractor:Front Range Concrete Technician:Matte, Ryan Cast By:Matte, Ryan Date Cast:11/29/23 Sampled From:Truck Placement Method:Chute Sample Details Batched:10:55 MST Sampled:11:34 MST Cast:11:49 MST Truck Empty:12:00 MST Placement Time:65 (min) Placement Location:Inlet Top Slab Location Details:Inlet decks for inlets I4-A.1, I4-A.2, F3-A, and F3-B on Aria Way south of Sykes Dr. Sample Location / Notes:MX 45260 Batch Log Strength:4500 (psi) Specifications Supplier:SRM Concrete On-Site Admixtures: 15.00 Gal Water (10 yd³) Location Field Measurements Plastic Unit Weight:142.0 (lb/ft³) Air Content:6.6 Load Volume:10.00 (yd³) Weather:sunny Slump (in):2-1/2 Air Temperature (F):37 Concrete Temp (F):73 Lab Test Results Testing Lab: Fort Collins, 400 North Link Lane, Fort Collins, CO, 80525 Test results relate only to the sample tested. Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064). This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc. Page 1 of 1 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-365 Compressive Strength of Concrete Test Method: ASTM C 39 Sample: 124184 Report #: CC-000702 Fort Collins 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Report Date: 01/24/2024