HomeMy WebLinkAboutCOMPRESSIVE STRENGTH OF CONCRETE - Filed CSS-COMPRESSIVE STRENGTH SUMMARY - (26)Specimen Number Test Age Days Test Date Field / Lab Cure Days Average Cylinder Diameter (in) Cylinder Area (in²) Max Load (lbs) Strength (psi) Fracture Type Break Remark Capping Method 178-1 7 11/29/23 1 / 6 4.00 12.57 45,820 3,650 3 N 178-2 28 12/20/23 1 / 27 4.00 12.57 58,920 4,690 3 C4 N 178-3 28 12/20/23 1 / 27 4.00 12.57 60,980 4,850 3 C4 N 178-4 28 12/20/23 1 / 27 4.00 12.57 60,850 4,840 3 C4 N 178-5 56 01/17/24 1 / 55 4.00 12.57 68,490 5,450 3 C4 N Test Age Average Strengths (psi): 7 Day - 3650, 28 Day - 4790, 56 Day - 5450 C4: Strength is greater than or equal to f'c. Tested By: Craig Ellis (1,2,3,4,5) Checked In : 11/23/2023 (1,2,3,4,5) Capping Methods N: Unbonded Caps (ASTM C1231) Set #:178 Specimen Size:4" X 8" Specimens In Set:5 Truck / Ticket #:1606 / 21093288 Contractor:Front Range Concrete Technician:England, Adam Cast By:England, Adam Date Cast:11/22/23 Sampled From:Chute Placement Method:Chute Sample Details Batched:08:33 MST Sampled:09:10 MST Cast:09:25 MST Truck Empty: Placement Time: Placement Location:Sidewalk Location Details:East side of street, approximately 370 feet north and 715 feet east of Delozier Road and Sykes Drive. Sample Location / Notes:Mix: 45260 Batch Log Strength:4500 (psi) Specifications Supplier:SRM Concrete On-Site Admixtures: None Location Field Measurements Plastic Unit Weight:141.6 (lb/ft³) Air Content:6.3 Load Volume:11.00 (yd³) Weather:Clear Slump (in):2 Air Temperature (F):50 Concrete Temp (F):69 Lab Test Results Testing Lab: Fort Collins, 400 North Link Lane, Fort Collins, CO, 80525 General Remarks 178-1: 81% of specified strength at 7 days. Test results relate only to the sample tested. Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064). This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc. Page 1 of 1 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-365 Compressive Strength of Concrete Test Method: ASTM C 39 Sample: 124047 Report #: CC-000700 Fort Collins 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Report Date: 01/17/2024