Loading...
HomeMy WebLinkAboutBloom Compressive Strength of Concrete - Filed CSS-COMPRESSIVE STRENGTH SUMMARY - (10)Specimen Number Test Age Days Test Date Field / Lab Cure Days Average Cylinder Diameter (in) Cylinder Area (in²) Max Load (lbs) Strength (psi) Fracture Type Break Remark Capping Method 194-1 7 12/26/23 1 / 6 4.00 12.57 61,380 4,880 3 N Test Age Average Strengths (psi): 7 Day - 4880 Tested By: Craig Ellis (1) Checked In : 12/20/2023 (1) Capping Methods N: Unbonded Caps (ASTM C1231) Set #:194 Specimen Size:4" X 8" Specimens In Set:5 Truck / Ticket #:2024 / 21093770 Contractor:Front Range Concrete Technician:Matte, Ryan Cast By:Matte, Ryan Date Cast:12/19/23 Sampled From:Truck Placement Method:Conveyor Sample Details Batched:10:34 MST Sampled:11:30 MST Cast:11:45 MST Truck Empty:11:55 MST Placement Time:81 (min) Placement Location:Sidewalk Location Details:North side of Sykes Dr. - adjacent to Lot 8 Block 6 Sample Location / Notes:Mix Design: 45260 Batch Log Strength:4500 (psi) Specifications Supplier:SRM Concrete On-Site Admixtures: None Location Field Measurements Plastic Unit Weight:143.0 (lb/ft³) Air Content:6.6 Load Volume:11.00 (yd³) Weather:Partly cloudy Slump (in):1-3/4 Air Temperature (F):58 Concrete Temp (F):65 Lab Test Results Testing Lab: Fort Collins, 400 North Link Lane, Fort Collins, CO, 80525 General Remarks 194-1: Reviewed by CE Test results relate only to the sample tested. Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064). This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc. Page 1 of 1 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-365 Compressive Strength of Concrete Test Method: ASTM C 39 Sample: 124862 Report #: CC-000654 Fort Collins 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Report Date: 12/26/2023