HomeMy WebLinkAboutBloom Compressive Strength of Concrete - Filed CSS-COMPRESSIVE STRENGTH SUMMARY - (9)Specimen Number Test Age Days Test Date Field / Lab Cure Days Average Cylinder Diameter (in) Cylinder Area (in²) Max Load (lbs) Strength (psi) Fracture Type Break Remark Capping Method 109-1 7 09/27/23 1 / 6 4.00 12.57 58,170 4,630 3 N 109-2 28 10/18/23 1 / 27 4.00 12.57 65,360 5,200 3 C4 N 109-3 28 10/18/23 1 / 27 4.00 12.57 68,720 5,470 3 C4 N 109-4 28 10/18/23 1 / 27 4.00 12.57 66,440 5,290 3 C4 N 109-5 56 11/15/23 1 / 55 4.00 12.57 76,470 6,080 3 C4 N Test Age Average Strengths (psi): 7 Day - 4630, 28 Day - 5320, 56 Day - 6080 C4: Strength is greater than or equal to f'c. Tested By: Craig Ellis (1,2,3,4,5) Checked In : 09/21/2023 (1,2,3,4,5) Capping Methods N: Unbonded Caps (ASTM C1231) Set #:109 Specimen Size:4" X 8" Specimens In Set:5 Truck / Ticket #:2029 / 21091376 Contractor:Front Range Concrete Technician:Matte, Ryan Cast By:Matte, Ryan Date Cast:09/20/23 Sampled From:Truck Placement Method:Chute Sample Details Batched:13:34 MDT Sampled:14:05 MDT Cast:14:20 MDT Truck Empty:14:45 MDT Placement Time:71 (min) Placement Location:Manhole Location Details:Storm manhole SDMH J4.1 on Aria Way Sample Location / Notes:Mix Design: 45262 Batch Log Strength:4500 (psi) Specifications Supplier:SRM Concrete On-Site Admixtures: None Location Field Measurements Plastic Unit Weight:143.7 (lb/ft³) Air Content:6.2 Load Volume:8.00 (yd³) Weather:Slump (in):3 Air Temperature (F):78 Concrete Temp (F):83 Lab Test Results Testing Lab: Fort Collins, 400 North Link Lane, Fort Collins, CO, 80525 General Remarks 109-1: 103% of specified strength at 7 days. Test results relate only to the sample tested. Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064). This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc. Page 1 of 1 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-365 Compressive Strength of Concrete Test Method: ASTM C 39 Sample: 121101 Report #: CC-000653 Fort Collins 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Report Date: 12/26/2023