Loading...
HomeMy WebLinkAboutBloom Compressive Strength of Concrete - Filed CSS-COMPRESSIVE STRENGTH SUMMARY - (7)Specimen Number Test Age Days Test Date Field / Lab Cure Days Average Cylinder Diameter (in) Cylinder Area (in²) Max Load (lbs) Strength (psi) Fracture Type Break Remark Capping Method 154-1 7 11/02/23 1 / 6 4.00 12.57 59,260 4,710 3 N 154-2 28 11/23/23 1 / 27 4.00 12.57 73,450 5,840 3 C4 N 154-3 28 11/23/23 1 / 27 4.00 12.57 74,340 5,910 3 C4 N 154-4 28 11/23/23 1 / 27 4.00 12.57 73,970 5,890 3 C4 N 154-5 56 12/21/23 1 / 55 4.00 12.57 77,040 6,130 3 C4 N Test Age Average Strengths (psi): 7 Day - 4710, 28 Day - 5880, 56 Day - 6130 C4: Strength is greater than or equal to f'c. Tested By: Craig Ellis (1,2,3,4,5) Checked In : 10/27/2023 (1,2,3,4,5) Capping Methods N: Unbonded Caps (ASTM C1231) Set #:154 Specimen Size:4" X 8" Specimens In Set:5 Truck / Ticket #:1623 / 21092548 Contractor:From Range Concrete Technician:Matte, Ryan Cast By:Matte, Ryan Date Cast:10/26/23 Sampled From:Truck Placement Method:Chute Sample Details Batched:08:36 MDT Sampled:09:22 MDT Cast:09:37 MDT Truck Empty:09:50 MDT Placement Time:74 (min) Placement Location:Manhole Location Details:Manhole for Area Inlet F4.1 and F5.1 south of Sykes Dr. Sample Location / Notes:Mix Design: 45262 Batch Log Strength:4500 (psi) Specifications Supplier:SRM Concrete On-Site Admixtures: 2.00 Bag WR-Low Range Water Reducing Admixture (8.5 yd³) Location Field Measurements Plastic Unit Weight:142.7 (lb/ft³) Air Content:6.0 Load Volume:8.50 (yd³) Weather:Slump (in):3-1/4 Air Temperature (F):43 Concrete Temp (F):65 Lab Test Results Testing Lab: Fort Collins, 400 North Link Lane, Fort Collins, CO, 80525 General Remarks 154-1: 105% of specified strength at 7 days. Test results relate only to the sample tested. Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064). This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc. Page 1 of 1 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-365 Compressive Strength of Concrete Test Method: ASTM C 39 Sample: 122871 Report #: CC-000650 Fort Collins 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Report Date: 12/21/2023