ADDENDUM NO. 1
SPECIFICATIONS AND CONTRACT DOCUMENTS
D escription of Bid 9919 Pre-Procurement of Ultraviolet Disinfection System
OPENING DATE: 3:00 PM (Our Clock) January 16, 2023
To all prospective bidders under the specifications and contract documents described above, the
following changes/additions are hereby made and detailed in the following sections of this
addendum :
1.T he Due Date for Bid 9919 is extended to January 16, 2024 at 3:00 PM.
2.In the attached Exhibit, some of the responses by the City require additional
information. That additional information is to be submitted with the Bid
response.
3.Additional changes:
•Added # ballasts in service on 'average day flow criteria' sheet.
•Added sleeve replacement to 'Cost Summary' sheet.
•Revised Total Lamp Power @ ADAF cell on 'Cost Summary' sheet to
reference Power cell I9 on 'Average Day Flow Criteria' sheet.
•Added Note (1) on 'Average Day Flow Criteria' sheet.
4. The Revised Bid Price Spreadsheet is issued separately on BidNet, as part of
this addendum.
Exhibit 1 – Questions and Answers
Please contact Pat Johnson, CPPB, Senior Buyer at pjohnson@fcgov.com with any questions
regarding this addendum.
RECEIPT OF THIS ADDENDUM MUST BE ACKNOWLEDGED BY A WRITTEN STATEMENT
ENCLOSED WITH THE BID STATING THAT THIS ADDENDUM HAS BEEN RECEIVED.
Financial Services
Purchasing Division
215 N. Mason St. 2nd Floor
PO Box 580
Fort Collins, CO 80522
970.221.6775
970.221.6707
fcgov.com/purchasing
Exhibit 1
Q1. Cost Summary Sheet – Cell G17 is pulling from the “non-prorated” ballast life of one year instead of the Guaranteed ballast life of 5 years. The calculation for Annual # Ballasts Replaced
in cell E25 should use the guaranteed ballast life of 5 years. The way the calculation is set up,
all ballasts in the system are replaced annually.
A1. Ballast life in cell G17 revised calculation to reference guaranteed life (5 yr).
Q2. Cost Summary Sheet – Cell E25, Annual # Ballasts Replaced is calculated using total
installed ballasts and not total operational ballasts at average flow. The total installed ballasts
includes the redundant ballasts that will not be operational.
A2. Annual # ballasts replaced in cell E25 revised calculation to reference # ballasts
in service on sheet "Average Day Flow Criteria", cell G9.
Q3. Lamp sleeve information is requested on the Warranty Replacement Costs sheet, however,
lamp sleeves are not utilized on the cost summary or 20 Yr LCCA sheets. Quarts sleeves
should be factored into the 20 Yr LCCA.
A3. Assumption is sleeves will be replaced at 20 yrs. Cost of one full batch of sleeve replacements added to 20 yr LCCA.
Q4. Cost Summary Sheet – on line 25, all annual costs are rounded up to the nearest
$1000. ie. $4,001 and $4,999 would be rounded up to $5,000 and result in the same annual
amount. Over the 20 Yr LCCA this could amount to a significant difference. Should these be
actual results and not rounded for a more accurate comparison.
A4. Removed all rounding from 'Cost Summary' and '20 yr LCCA' sheets, except for final life cycle cost calculation in cell M33 on sheet '20 yr LCCA'.
SECTION PARAGRAPH SPECIFICATION REQUIREMENT QUESTION RESPONSE
00300 11A.
Bid Submittal – 11 A. Is the entered value here to actually be the
20 year life cycle cost or the Total Capital
Cost from the bid Price Forms? If it is to be
20 year life cycle please confirm if this
comes from the 20 Yr LCCA tab on the bid
price forms, line item 33
The value that will be most used for
cost evaluation is line 33 on the “20
Yr LCCA” tab. Other items will be
evaluated to ensure a balanced and
qualified bid are awarded.
46 66 53
2.4.
And
3.6 D.
Provide a theoretical electrical
system harmonics study for the
electrical distribution system
including utility
Will Generic UV3+ harmonic study be
acceptable and/or is this in addition to the
requirements of 3.6 D.
Requirements of 3.3.D is in addition
to 2.4. A generic UV3+ harmonic
study is acceptable during submittal
phase, but electrical acceptance
tests are required to verify
performance of installed
components.
46 66 53 - 24 2.5 C.3.a
HMI screens shall be developed per
OWNER standards and as per
specification Section 40 95 10 - PLC
Based Control Systems Hardware.
The
SUPPLIER shall schedule a meeting
with the OWNER to discuss graphic
screen development prior to start
of construction.
Is it acceptable to use Trojan standard
screens
Supplier screens are generally
acceptable. Contract equipment
tagging shall be utilized. Sample
screens shall be provided prior to
graphics meeting with the owner
for review/discussion for final
approval.
46 66 53 - 24 2.5 C.3.a
Screens shall be developed utilizing
Schneider Ecostruxture Software.
Trojan Modicon HMI programs use Vijeo
desiger v6.2. Is this acceptable?
No exception to the HMI software is
allowed.
46 66 53 - 26 2.5 C.5.b.9
High temperature Please confirm what this is monitoring -
Custom programming will be required
This is in reference to PDC high
temperature.
46 66 53 - 29 2.5.F.2.b
UVT probe shall be model IQ UVT-
254 by YSI Incorporated.
Are either Trojan standard options
acceptable : Real Tech Inc.UV254 P200 UVT
meter or HACH SC4500 UVT-254 for Online
UVT.
No OR EQUAL UVT instruments shall
be considered.
46 66 53 - 33 3.6.A.
The OWNER shall be given 45
calendar days notice prior to testing
and the SUPPLIER shall provide and
coordinate all travel
accommodations for the Factory
Testing
Is the UV manufacturer responsible for the
owners travel expenses. If so , this section
does not indicate how many
representatives will be attending.
Please clarify.
Owner will be responsible for their
own travel expenses. However,
Vendor should be ready for up to
Six (6) representatives for any
conference room or other on-site
accommodations.
46 66 53 3.6.C.2
Laboratory analyses will be
performed by the OWNER. All
laboratory test results shall
be submitted by the OWNER and
forwarded to the SUPPLIER.
Will Owner or Supplier cover cost of
equipment and lab expenses?
Owner will cover the cost of
laboratory testing in their own lab.
40 92 00 - 3 2.2.A.1
Panel section faces shall be No. 10
gauge minimum thickness for free
standing panels
Our standard for free standing panel is 12
gauge. Is this acceptable?
Provide a price deduct option for
substituting 12 gauge in lieu of 10
gauge.
40 92 00 - 7 2.2.H.12.d
A 15 amp, 2 pole circuit breaker
shall be provided in each branch
circuit.
Trojan use single pole breaker for single
phase power source. Is this acceptable?
Yes , paragraph 2.2.H.12.d indicates
single pole 15 amp breaker.
Page 1 of 3
0BPg 1BSpec Reference 2BSpec Comments 3BResponse
92 26 00 00 Please allow for at least 8 weeks to provide submittal
documents.
No exceptions allowed .
123 26 35 26
1.1.A We take exception as proposed system will be IEEE519
compliant without the active filter.
Installation shall meet the requirements of
IEEE519 for THD. Certificate of compliance
shall be provided.
139 40 91 00
1.2.D.3 &4 Please allow for the loop drawings to be submitted after the
drawings and schematics are approved in order to capture any changes.
Yes. This is fine.
158 40 91 06
2.1.A-C Please consider our standard, Endress & Hauser FTW31, as an
approved equal.
Per P&ID, continuous level measurement
is required on each channel. FTW31 is
acceptable for level switches, but shall not
replace continuous level measurement .
165 40 92 00
2.1.H We take exception our discrete outputs are 24VDC. Discrete outputs from the control panel
shall be provided by elec trically isolated
contacts rated for 5 amps at 120 VA C.
165 40 92 00
2.1.K We will be supplying our standard Rittal cabinets with our standard outer coating with no coatings on the inside.
Outer coating shall be in accordance with
this section. Provide details to the
WEDECO s tandard outer coating if a
variance is requested for review.
165 40 92 00
2.2 A thru I We will be supplying our standard Rittal cabinets and
components and our standard wiring methods.
Control panel shall mee t the requirements
of this section. Provide detailed exceptions
where the installation doesn’t meet the
requirements for re view.
170 40 92 00
2.3 We will be supplying will be supplying our standard Rittal
cabinets.
Control panel shall mee t the requirements
of this section. Provide detailed exceptions
where the installation doesn’t meet the
requirements for re view.
Specification Review
Project: City of Fort Collins - Mulberry
2
0BPg 1BSpec Reference 2BSpec Comments 3BResponse
172 40 92 00 3.2.E We will be supplying will be supplying our standard Rittal
cabinets.
Manufacturer to ensure labels will be
durable and have good longevity
174 40 95 10
1.3 Wire labels are not adhesive labels and we don’t provide a
portable label marker “Brady, BMP 41 Model”.
A single submittal for the PLC control
panel (control panel, plc and supporting
hardware) is acceptable
182 40 95 10
2.6.C Please confirm if a separate submittal is required just for the
PLC, the schematics will need to be accepted and full PLC
program completed. Please allow for 4-5 months.
Generally structured text is not allowed.
Please provide an explanation of why it is
necessary.
186 40 95 10
3.5.A We take exception. We use ladder mainly throughout the
program but need to use structured text for some items.
Summary description of multiple rungs is
acceptable .
239 46 66 53
2.2.A.1 We take exception for each rung having a description. We use
ladder mainly throughout the program but need to use structured
text for some items.
Desig n intent is to have two banks per
cabinet with a redundant channel (if one
cabinet goes down, the second channel
provides disinfection). With a redundant
bank per channel, there would need to be
two cabinets per channel and both
channels running if a cabinet goes down,
which deviates from design intent . Please
describe the imp acts of maintaining a
redundant channel instead of redundant
bank per channel.
242 46 66 53
2.3.A.4.g Please consider returning to previous allowance of “redundant
bank per channel at peak during the peak flow of 6 MGD and at a UVT of 65% while delivering a dose of 30 mJ/cm2”.
No exceptio ns allowed .
243 46 66 53
2.3.A.6.b Please allow for maximum option without flow is 60 min. No exceptions allowed .
243 46 66 53
2.3.A.7 .d/g We take exception. Our banks are not rated for complete submerg ence
and are not Type 6P .
Noted. Please provide a description of
what would happen if the water level in the
UV c hannel overtopped the banks, and
what repairs might be req uired.
3
0BPg 1BSpec Reference 2BSpec Comments 3BResponse
251 46 66 53 2.3.J.5.a Please consider our standard 304SS . Assuming this spec reference was meant
to be 2.3.K.5.a (junction box). See Exhibit
A Price Forms, Pirce Schedule tab, row 48
–304S S acceptable as offering with price
deduct .
252 46 66 53
2.4.5
Please allow for submission after submittal as the harmonic s tudy is
dependent on the schematics and other s ubmittal documents.
No exceptions allowed.