Loading...
HomeMy WebLinkAboutPROSPECT SPORTS CLUB - PDP230009 - SUBMITTAL DOCUMENTS - ROUND 3 - STORMWATER-RELATED DOCUMENTSStormwater Alternative Compliance/Variance Application City of Fort Collins Water Utilities Engineering Section A: Engineer/Owner Information Engineer Name____________________________________________Phone___________________________ Street Address_____________________________________________________________________________ City__________________________________________State________________________Zip_____________ Owner Name______________________________________________Phone___________________________ Street Address_____________________________________________________________________________ City__________________________________________State________________________Zip_____________ Section C: Alternative Compliance/Variance Information Section B: Proposed Project Information Legal description and/or address of property____________________________________________________ Project Name______________________________________________________________________________ Project/Application Number from Development Review (i.e. FDP123456)__________________________ Description of Project_______________________________________________________________________ __________________________________________________________________________________________ Existing Use (check one): ☐ residential ☐ non-residential ☐ mixed-use ☐ vacant ground Proposed Use (check one): ☐ residential ☐ non-residential ☐ mixed-use ☐ other____________________ If non-residential or mixed use, describe in detail_______________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ State the requirement from which alternative compliance/variance is sought. (Please include applicable Drainage Criteria Manual volume, chapter and section.) What hardship prevents this site from meeting the requirement? What alternative is proposed for the site? Attach separate sheet if necessary Attach separate sheet if necessary Kevin Brazelton 970-530-4044 19 Old Town Square #238 Fort Collins CO 80524 Max West Inc (Attn:Jonathan O'Neil)970-218-9453 1500 Buckeye Street Fort Collins CO 80525 Prospect Sports Club Lot 5,Prospect Park East,PUD,FTC Development of existing vacant lot into a sports complex Property to be developed into a sports complex containing (2)gymnasiums and associated supporting infrastructure. Alt.Compliance -Section 6,Detention See attached. See attached. page 2 The owner agrees to comply with the provisions of the zoning ordinance, building code and all other applicable sections of the City Code, Land Use Code, City Plan and all other laws and ordinances affecting the construction and occupancy of the proposed building that are not directly approved by this variance. The owner understands that if this variance is approved, the structure and its occupants may be more susceptible to fl ood or runoff damage as well as other adverse drainage issues. Signature of owner:_____________________________________________Date:_______________________ The engineer hereby certifi es that the above information, along with the reference plans and project descriptions is correct. Signature of engineer:___________________________________________Date:_______________________ PE STAMP If you have questions or need assistance fi lling out forms, contact Fort Collins Utilities at: Phone: 970-221-6700 · TDD 970-224-6003 Web: fcgov.com/stormwater · Email: WaterUtilitiesEng@fcgov.com Utilities Of f i c e u s e o n l y Date complete application submitted:_____________ Date of approval/denial:__________________________ Variance: ☐ approved ☐ denied Staff justifi cation/notes/conditions:_______________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ Approved by:__________________________________ Entered in UtilityFile Database? ☐ yes ☐ no 12/13/23 12/13/23 S TORMWATER V ARIANCE R EQUEST P ROSPECT S PORTS C LUB F ORT C OLLINS ,CO 19 OLD TOWN SQUARE #238 | FORT COLLINS, CO 80524 | 970-530-4044 | www.unitedcivil.com December 20, 2023 DAN MOGEN 700 WOOD STREET FORT COLLINS,CO 80522 RE: STORMWATER ALTERNATIVE COMPLIANCE AND VARIANCE REQUESTS PROSPECT SPORTS CLUB –1600 EAST PROSPECT ROAD PROJECT NUMBER:U22014 Dan, This letter is being submitted on behalf of the owners of the Prospect Sports Club development. The project is currently in the Preliminary Development Plan process and currently one (1) variance is being requested to modify portions of the Fort Collins Stormwater Criteria Manual as follows: VARIANCE REQUEST –STORMWATER DETENTION STANDARDS DESIGN CRITERIA OF VARIANCE BEING REQUESTED Section 6.0 within the Fort Collins Stormwater Criteria Manual which states: Onsite detention is required for all development projects. The required minimum detention volume and maximum release rate(s) for the developed condition 100-year recurrence interval storm must be determined in accordance with the conditions and regulations established in the appropriate Master Drainage Plan(s) for that area of the City, for the development and in accordance with the criteria set forth in this Manual. HARDSHIP REGARDING REQUIREMENT The site is located at 1600 East Prospect Road within Prospect Park East P.U.D and is surrounded by existing fully developed commercial properties to the south (Advanced Energy) and west (Larimer County Coroner) along with Prospect Road and Sharp Point to the north and east respectively. The original subdivision development planned for drainage to be conveyed via overland flow to the drainage facility located south of the site; therefore, no storm sewer currently exists on the site. However, the original subdivision plat did not include drainage easements on the property to allow for the conveyance of 100-year stormwater runoff from the site, across the property to the south and to the existing drainage facility. After discussion with the south property owner and their attorney, the southern property owner has denied any new easements on their property. Refer to Appendix A for an email from the south property owner regarding the denial of new easements. Therefore, the site cannot utilize the detention system within the subdivision. Storm sewer for the project, required to convey both water quality and 100-year developed stormwater flows, is proposed to convey runoff to the east across Sharp Point to the existing property also owned by the developer of the Prospect Sports Club facility to avoid the need for drainage easements south of the site. PROPOSED ALTERNATE DESIGN The existing subdivision detention facility located south of the project site drains to the existing pond located east of Sharp Point prior to being released to the Poudre River. Coincidentally, the property east of Sharp Point where this existing pond is located is also owned by the developer of the Prospect Sports project. As such, the development team proposes to drain 100-year undetained flows from the Prospect Sports site directly to this existing pond, bypassing the subdivision detention facility and negating the need for drainage easements on properties south of the development site. The following sections of this variance request documents the negligible impacts this alternate design will cause the downstream pond and property. S TORMWATER V ARIANCE R EQUEST P ROSPECT S PORTS C LUB F ORT C OLLINS ,CO 19 OLD TOWN SQUARE #238 | FORT COLLINS, CO 80524 | 970-530-4044 | www.unitedcivil.com The existing detention facility was analyzed in the approved drainage report entitled, “Final Drainage and Erosion Control Plan – Advanced Energy Buildings 7 & 8”, by Park Engineering Consultants and dated June 11, 1999, see Appendix A for excerpts. In said report, the detention facility was found to require a total volume of 8.94 ac-ft; however, the facility only has a volume of 7.69 ac-ft to the centerline of Sharp Point prior to overtopping, by approximately 0.32-feet, and draining directly to the existing pond east of Sharp Point. With this request, it is calculated that the proposed development would account for approximately 0.43 ac-ft of the required volume in the existing detention facility. By piping the undetained 100-year flows from the proposed development directly to the existing pond east of Sharp Point: 1.The existing detention storage deficit in the facility to the south is reduced. 2.The amount of flow overtopping of Sharp Point is reduced. 3.The net volume of undetained storage the existing pond east of Sharp Point remains the same. Additionally, it should be noted that the existing pond east of Sharp Point is approximately 6.1-acres in size. With the required detention volume of the site of 0.43 ac-ft being attenuated within the existing pond, rather than detained onsite, the rise in depth in the existing pond would be less than 1-inch. Based on the information provided for this detention variance request, it is the design teams opinion that the proposed design will improve the function of downstream infrastructure (i.e. the existing detention facility to the south and the overtopping of Sharp Point), will have negligible impacts to the existing pond east of Sharp Point and will have no negative impacts on City infrastructure, downstream properties or the safety of the public. On behalf of the owners of the Prospect Sports Club and the design team, we thank you for the consideration of this request. If you should have any questions or comments regarding this request, please feel free to contact us at your convenience. Sincerely, United Civil Design Group, LLC Kevin Brazelton, PE Principal APPENDIX A – Referenced Materials A PPENDIX A R EFERENCED M ATERIALS From: Jerad Nielsen <JNielsen@capitalsq.com> Sent: Monday, January 9, 2023 12:10 PM To: Erika Ashauer <eashauer@rbbarchitects.com> Cc: Terri Hanna <terri@wwreynolds.com>; Jeff Wingert <jwingert@wwreynolds.com> Subject: RE: 1600 E. Prospect Road Fort Collins, CO Hi Erika – Just tried your office line and missed you. I believe there is currently an easement in place that allows access off Sharp Point Drive through our existing drive lane to your proposed site. We are not interested in entering into a parking share agreement or providing additional easements. Please note that our tenant (Advanced Energy) does not have the authority to enter into any arrangement. Please call me if you would like to discuss further – 804.357.1852. As reference, I have copied our local management team who oversees the property management of this building and also the association. Thank you, Jerad Nielsen, CPM ®, CCIM ® Vice President, Asset Management 10900 Nuckols Road, Suite 200 |Glen Allen, VA 23060 P: 804.290.7900 | E: jnielsen@capitalsq.com C: 804.357.1852 From: Erika Ashauer <eashauer@rbbarchitects.com> Sent: Wednesday, December 28, 2022 5:20 PM To: Jerad Nielsen <JNielsen@capitalsq.com> Subject: 1600 E. Prospect Road Fort Collins, CO Hi Jerad, Please see below emails regarding agreements and easements between our property at Prospect Park East PUD and your property (Advanced Energy). Thank you, Erika Ashauer, ALEP | Project Coordinator Direct: (970) 488-3870 From: Erika Ashauer Sent: Wednesday, December 21, 2022 10:25 AM To:jnielsen@capitalsquare1031.com Subject: FW: 1600 E. Prospect Road Good morning, Jared. I wanted to follow up with you on the below email regarding agreements and easements at Prospect Park East PUD. Feel free to give me a call (number below in signature) if that would be easier to discuss. Happy Holiday’s! Erika Ashauer, ALEP | Project Coordinator Direct: (970) 488-3870 From: Erika Ashauer <eashauer@rbbarchitects.com> Sent: Wednesday, December 14, 2022 3:42 PM To:jnielsen@capitalsquare1031.com Cc: 2204 Prospect East <2204ProspectEast@rbbarchitects.com> Subject: 1600 E. Prospect Road Hi Jerad, I am part of the architectural team at RB+B Architects working on the Prospect Sports facility being developed in Prospect Park East PUD, Lot 5. I will be the liaison between the Prospect Sports owner and our team, and the adjacent property owners. Have you been able to locate any existing access agreements between your property (Advanced Energy) and ours? I have not yet found any existing agreements in public records. If there are no existing agreements, we would like to submit the following for your consideration: 1.Access Easement: We would like to share the same drive used to access the Advanced Energy buildings off of Sharp Point Drive as the main point of entry to our site 2.Emergency Access Easement: Our site is relatively small, and we have determined that the fire department cannot access our lot off Prospect Rd. and will need access on the southern side of the site. The emergency access would impact the AE site by extending the lane to the eastern portion of the property so the fire lane can wrap around our property to the East. This would cause a loss of a few parking spaces and trees on your property. 3.Parking Share Easement: Since our lot is relatively small for the proposed building of approximately 35,000 square feet, we are limited to the number of parking spaces on our lot. We are currently planning on 49 parking spaces on our property. The City of Fort Collins routinely allows for parking share agreements between adjacent properties so that adequate parking is available while not creating an abundance of hardscaped areas dedicated to parking. Prospect Sports is expected to experience high vehicular parking during off-business hours: the evenings and weekends. We hope that patrons of Prospect Sports could use the AE parking lot as overflow parking during these peak times and the Prospect Sports parking would be available for AE use as well. I have attached a site plan with the proposed easements diagramed. Please do not hesitate to reach out to me should you want to discuss further. Thank you, Erika Ashauer, ALEP| Project Coordinator RB+B Architects Direct: (970) 488-3870 eashauer@rbbarchitects.com | rbbarchitects.com This unofficial copy was downloaded on Jul-06-2022 from the City of Fort Collins Public Records Website: http://citydocs.fcgov.com For additional information or an official copy, please contact City of Fort Collins Utilities 700 Wood Street Fort Collins, CO 80524 USA This unofficial copy was downloaded on Jul-06-2022 from the City of Fort Collins Public Records Website: http://citydocs.fcgov.com For additional information or an official copy, please contact City of Fort Collins Utilities 700 Wood Street Fort Collins, CO 80524 USA This unofficial copy was downloaded on Jul-06-2022 from the City of Fort Collins Public Records Website: http://citydocs.fcgov.com For additional information or an official copy, please contact City of Fort Collins Utilities 700 Wood Street Fort Collins, CO 80524 USA This unofficial copy was downloaded on Jul-06-2022 from the City of Fort Collins Public Records Website: http://citydocs.fcgov.com For additional information or an official copy, please contact City of Fort Collins Utilities 700 Wood Street Fort Collins, CO 80524 USA EXISTING DETENTION FACILITY SITE LOCATION EXISTING POND LOCATION OUTLET AND OVERTOPPING OF DETENTION FACILTY PAST SHARP POINT FLOWS INTO EXISTING POND DETENTION POND VOLUME (FAA Method) Prospect Sports POND ID:Required Onsite Pond Volume Calculation for Variance Request 100 Year Storm Into Detention Facility Area =109,103 square feet Area =2.50 acres C 100 = 0.74 Q 100 = 13.70 cfs Release Rate Out of Pond Q OUT = 1.48 cfs Unit Flow =0.59 cfs/acre T C =11.0 minutes Notes: 1. Release Rate controlled by 2 yr historic Detention Volume Calculations Rainfall Rainfall Inflow Rate Inflow Volume Adjustment Factor Average Outflow Volume Required Duration (T)Intensity (I)Qin= ∑C100*Area*I Vi=(Qin*T*60)Factor Outflow Rate Vo=Qav*T *60 Storage Volume m= 0.5(1 + Tc/T) Qav = m*Qout Vs=Vi-Vo min in/hr cfs ft 3 cfs ft 3 ft 3 5 9.95 18.4 5,511 1.00 1.48 445 5,066 10 7.72 14.3 8,552 1.00 1.48 891 7,662 15 6.52 12.0 10,835 0.87 1.29 1,158 9,677 20 5.60 10.3 12,408 0.78 1.15 1,380 11,027 25 4.98 9.2 13,792 0.72 1.07 1,603 12,189 30 4.52 8.3 15,022 0.68 1.01 1,826 13,196 35 4.08 7.5 15,820 0.66 0.98 2,048 13,771 40 3.74 6.9 16,573 0.64 0.95 2,271 14,302 45 3.46 6.4 17,249 0.62 0.92 2,494 14,755 50 3.23 6.0 17,891 0.61 0.91 2,716 15,175 55 3.03 5.6 18,462 0.60 0.89 2,939 15,523 60 2.86 5.3 19,010 0.59 0.88 3,162 15,849 70 2.59 4.8 20,085 0.58 0.86 3,607 16,478 80 2.38 4.4 21,093 0.57 0.84 4,052 17,041 90 2.21 4.1 22,035 0.56 0.83 4,498 17,537 100 2.06 3.8 22,821 0.56 0.82 4,943 17,878 110 1.94 3.6 23,641 0.55 0.82 5,388 18,253 120 1.84 3.4 24,461 0.55 0.81 5,834 18,627 Required Detention Volume V 100 = 18,627 cubic feet V 100 = 0.43 acre-ft Date: 12/13/2023 C:\United Civil Dropbox\Projects\U22014 - Prospect Park East\Reports\Drainage\Calculations\U22014-Drain Calcs.xlsm