Loading...
HomeMy WebLinkAboutCOMPRESSIVE STRENGTH OF CONCRETE TEST - Filed CT-CONCRETE TEST -Specimen Number Test Age Days Test Date Field / Lab Cure Days Average Cylinder Diameter (in) Cylinder Area (in²) Max Load (lbs) Strength (psi) Fracture Type Break Remark Capping Method 158-1 7 11/10/23 1 / 6 4.00 12.57 52,050 4,140 3 N 158-2 28 12/01/23 1 / 27 4.00 12.57 59,680 4,750 3 C4 N 158-3 28 12/01/23 1 / 27 4.00 12.57 62,980 5,010 3 C4 N 158-4 28 12/01/23 1 / 27 4.00 12.57 60,310 4,800 3 C4 N 158-5 56 12/29/23 1 / 55 4.00 12.57 75,980 6,050 3 C4 N Test Age Average Strengths (psi): 7 Day - 4140, 28 Day - 4850, 56 Day - 6050 C4: Strength is greater than or equal to f'c. Tested By: Craig Ellis (1,2,3,4,5) Checked In : 11/04/2023 (1,2,3,4,5) Capping Methods N: Unbonded Caps (ASTM C1231) Set #:158 Specimen Size:4" X 8" Specimens In Set:5 Truck / Ticket #:1905 / 21092717 Contractor: Technician:Huemmler, Thomas Cast By:Huemmler, Thomas Date Cast:11/03/23 Sampled From:Chute Placement Method:Conveyor Sample Details Batched:11:29 MDT Sampled:12:20 MDT Cast:12:35 MDT Truck Empty: Placement Time: Placement Location:Sidewalk Location Details:Sidewalk, Whisperwind Lane in front of Lot 6 Block 1 Sample Location / Notes:Mix ID: 45260 Batch Log Strength:4500 (psi) Specifications Supplier:SRM Concrete On-Site Admixtures: 10.00 Gal Water (11 yd³) Location Field Measurements Plastic Unit Weight:142.8 (lb/ft³) Air Content:6.2 Load Volume:11.00 (yd³) Weather:Slump (in):1-3/4 Air Temperature (F):Concrete Temp (F):78 Lab Test Results Testing Lab: Fort Collins, 400 North Link Lane, Fort Collins, CO, 80525 General Remarks 158-1: 92% of specified strength at 7 days. Reviewed by CE Test results relate only to the sample tested. Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064). This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc. Page 1 of 1 Client: Hartford Homes Construction Timnath, CO 80547 4801 Goodman St Project: Bloom Filing 1 FC07733.001F-365 Compressive Strength of Concrete Test Method: ASTM C 39 Sample: 123277 Report #: CC-000663 Fort Collins 400 North Link Lane Fort Collins, CO 80524 Phone: 970-206-9455 Report Date: 12/29/2023