PAKIZ SUBDIVISION - MINOR AMENDMENT - MA230138 - SUBMITTAL DOCUMENTS - ROUND 1 - ARCHITECTURAL DETAILS
10x13/6 OHD10x13/6 OHD 10x13/6 OHD10x13/6 OHD 10x10/6 OHD10x10/6 OHD 3068 3068 312 1414 1726 15791030 1413 2233 3646 4' - 0 " 29'8" X 14'0" 4' - 0 " 9'-8" 3' - 8 " Denotes room with framed ceiling. Space above is non-habitable mezzanine/storage area. NOTE: SPIRAL STAIR INSTALLATION REQUIRES SEPARATE PERMIT NOTE: HOT TUB INSTALLATION REQUIRES SEPARATE PERMIT NOTE: HOT TUB INSTALLATION REQUIRES SEPARATE PERMIT 5/8" DENSGLASS TYPE X SHEATHING AT ALL EXTERIOR EXPOSED PORTIONS OF WALLS ALONG AREA SEPARATION WALL 1' - 1 " 2' - 7 " 5/8" DENSGLASS TYPE X SHEATHING AT ALL EXTERIOR EXPOSED PORTIONS OF WALLS ALONG AREA SEPARATION WALL 5/8" DENSGLASS TYPE X SHEATHING AT ALL EXTERIOR EXPOSED PORTIONS OF WALLS ALONG AREA SEPARATION WALL AREA SEPARATION FIRE WALLS GA FILE NO. ASW 1000 PROPRIETARY* 2 HOUR FIRE 60 to 64 STC SOUND GYPSUM PANELS, STEEL H STUDS Fire Design: Two layers 1” x 24” proprietary type X gypsum panels inserted between 2” floor and ceiling runners with 2” steel H studs between adjacent pairs of gypsum panels. A 3/4” minimum air space must be maintained between steel components and adjacent framing (as indicated by dashed lines in sketch). As an alternate to an air space, the steel components are covered with 6” wide battens of 1/2” gypsum panel or 1” mineral fiber insulation. As an alternate to battens, one or both faces of the separation wall are covered with 1” mineral fiber insulation stapled to the gypsum liner panels or 1/2” proprietary type X gypsum panel screw attached to the steel components. Height limitation 66 feet. (NLB) Refer to the manufacturer for the thermal protection of the framing. Sound Design: Sound tested with 2 x 4 stud wall faced with 1/2” regular gypsum panel each side of assembly and 3” mineral fiber in stud space on both sides. PROPRIETARY GYPSUM PANEL United States Gypsum Company................ 1” Sheetrock ® Brand Gypsum Liner Panels Thickness: 3-1/2” (Fire) 11-3/4” (Sound) Approx. Weight: 9 psf (Fire and Sound) Fire Test: UL R1319, 89NK28786, 5-14-90, UL Design U336; UL R1319, 94NK40690, 1-27-95, UL Design V411; WHI 495-PSV-0245, 4-28-83 Sound Test: RAL TL88-350, 9-12-88 LEVEL 1 LEFT UNIT LEVEL 2 LEFT UNIT MEZZANINE/STORAGE LEFT UNIT MEZZANINE/STORAGE RIGHT UNIT LEVEL 2 RIGHT UNIT LEVEL 1 RIGHT UNITGARAGE LEFT UNIT GARAGE RIGHT UNIT WHOLE BUILDING SECTION (SCHEMATIC) FRONT FACING - WITH MEZZANINE/LOFT CEILING HEIGHTS. FOUNDATION PLAN DU P L E X FO R T C O L L I N S , C O L O R A D O 10 2 6 L I N D E N G A T E C O U R T S1.1 FOUNDATION PLAN STRUCTURAL ENGINEERS ROOF FRAMING PLAN UPPER FLOOR AND LOWER DU P L E X FO R T C O L L I N S , C O L O R A D O 10 2 6 L I N D E N G A T E C O U R T S2.1 UPPER FLOOR AND LOWER ROOF FRAMING PLAN STRUCTURAL ENGINEERS FRAMING PLAN LOFT LEVEL DU P L E X FO R T C O L L I N S , C O L O R A D O 10 2 6 L I N D E N G A T E C O U R T S3.1 LOFT LEVEL FRAMING PLAN STRUCTURAL ENGINEERS FRAMING PLAN UPPER ROOF DU P L E X FO R T C O L L I N S , C O L O R A D O 10 2 6 L I N D E N G A T E C O U R T S4.1 UPPER ROOF FRAMING PLAN STRUCTURAL ENGINEERS DU P L E X FO R T C O L L I N S , C O L O R A D O 10 2 6 L I N D E N G A T E C O U R T S5.1 DETAILS & GENERAL NOTES STRUCTURAL ENGINEERS DU P L E X FO R T C O L L I N S , C O L O R A D O 10 2 6 L I N D E N G A T E C O U R T S5.2 DETAILS STRUCTURAL ENGINEERS FS1.0 FIRE SPRINKLER 04/01/22 FROM BELOW WATER ENTRY TO DOMESTIC TO DOMESTIC FEED DOMESTIC HOT FEED UPPER FIRE SPRINKLERS TO DOMESTIC TO DOMESTIC TO DOMESTIC TO DOMESTIC FROM BELOW WATER ENTRY FEED UPPER FIRE SPRINKLERS FEED UPPER FIRE SPRINKLERS 9'-0" H-1 VK470 12X12 H-2 VK470 12X12 H-3 VK468 18X18 H-4 VK470 12X12 H-5 VK470 12X12 H-6 VK470 12X12 H-7 VK470 12X12 H-8 VK470 12X12 H-9 (SW) VK484 16X16 H-10 VK470 12X12 H-11 VK470 12X12 H-12 VK470 12X12 H-13 VK470 12X12 H-14 VK468 18X18 H-15 VK468 18X18 H-1B VK470 12X12 H-2B VK484 12X123068SIDE- WALL HEAD P2904 MULTIPURPOSE SYSTEM - PRESCRIPTIVE DESIGN 1ST FLOOR SHUT-OFF VALVE AND DRAIN SHUT-OFF VALVE AND DRAIN 12/06/22 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361SS8361 SS8361 SS8464 12/20/22 - Revised VK470 Heads to SS8361 (Concealed) and VK468 Heads to SS8464 (Concealed) FS2.0 FIRE SPRINKLER 04/01/22 FROM ABOVE FROM BELOW FROM BELOW FROM BELOW FEED UPPER FIRE SPRINKLERS IN MASTER SUITE HIGH TEMPERATURE HEAD IN SAUNA 9' - 0 " 8'-0" SIDE- WALL HEAD 9' - 0 " 8' - 0 " H-16 VK468 18X18 H-18 VK468 16X16 H-17 VK470 12X12 H-19 VK470 12X12 H-20 VK329 12X12 H-21 VK470 12X12 H-22 VK470 12X12 H-23 VK470 12X12 H-4B VK484 16X16 H-3B VK468 18X18 H-5B VK470 12X12 TO DOMESTIC P2904 MULTIPURPOSE SYSTEM - PRESCRIPTIVE DESIGN 2ND FLOOR ROOMS WITH INTERMEDIATE CEILINGS SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8464 SS8464SS8464 12/20/22 - Revised VK470 Heads to SS8361 (Concealed) and VK468 Heads to SS8464 (Concealed) FS3.0 FIRE SPRINKLER 04/01/22 FROM BELOW FROM BELOW FROM BELOW FROM BELOW 12 ' - 0 " 5' - 0 " 6' - 0 " 12 ' - 0 " 12 ' - 0 " 10 ' - 0 " 8' - 9 " 6' - 0 " 3'-0"12'-0"9'-3"5'-6" 9'-0" 12'-0"12'-0"2'-0" 12 ' - 0 " 12 ' - 0 " 9' - 0 " 4' - 8 " 3' - 6 " 11 ' - 0 " 12 ' - 0 " H-24 VK470 12X12 H-25 VK470 12X12 H-29 VK470 12X12 H-33 VK470 12X12 H-34 VK470 12X12 H-26 VK470 12X12 H-27 VK470 12X12 H-30 VK470 12X12 H-31 VK470 12X12 H-32 VK470 12X12 H-37 VK470 12X12 H-38 VK470 12X12 H-39 VK470 12X12 H-42 VK470 12X12 H-43 VK470 12X12 H-44 VK470 12X12 H-45 VK470 12X12 H-46 VK470 12X12 6' - 0 " 12 ' - 0 " 10'-0" H-35 VK470 12X12 H-36 VK470 12X12 H-41 VK470 12X12 H-40 VK470 12X12 H-28 VK470 12X12 H-6B VK470 12X12 H-7B VK470 12X12 H-8B VK470 12X12 H-9B VK470 12X12 H-10B VK470 12X12 H-11B VK470 12X12 H-12B VK470 12X12 H-13B VK470 12X12 H-14B VK470 12X12 H-15B VK470 12X12 H-16B VK470 12X12 H-17B VK470 12X12 H-18B VK470 12X12 H-19B VK470 12X12 H-20B VK470 12X12 H-21B VK468 18X18 H-22B VK470 12X12 H-23B VK470 12X12 28 ' - 1 0 3 / 4 " 6'-9 3/4" P2904 MULTIPURPOSE SYSTEM - PRESCRIPTIVE DESIGN 2ND FLOOR VAULTED CEILINGS SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 SS8361 12/20/22 - Revised VK470 Heads to SS8361 (Concealed) and VK468 Heads to SS8464 (Concealed), Labeled most remote head on each unit (same location as previous plans). SS8464SS8464 MOST REMOTE HEAD (LEFT UNIT) MOST REMOTE HEAD (RIGHT UNIT) FS4.0 FIRE SPRINKLER 04/01/22 TECHNICAL DATA FREEDOM® RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) Form No. F_061011 19.02.21 Rev 19.1 Page 3 of 5 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval ChartViking VK470, 3.0 K-Factor Residential Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to the current editions of NFPA 13, 13R or 13D Sprinkler Base Part Number 1 SIN NPT Thread Size Nominal K-Factor Maximum Water Working Pressure Overall Length Inches mm U.S.metric 2 Inches mm 17147 VK470 1/2 15 3.0 43.2 175 psi (12 bar)2-1/4 58 Max. Coverage Area 4 Ft.X Ft. (m X m) Ordinary Temp Rating (155 °F/68 °C) Intermediate Temp Rating (175 °F/79 °C)Deflector to Ceiling Installation Type Listings and Approvals 3 Minimum Spacing Ft. (m)Flow 4 GPM (L/min) Pressure 4 PSI (bar) Flow 4 GPM (L/min) Pressure 4 PSI (bar) 5 NYC NSF 12 X 12 (3.7 X 3.7) 8 (30.3) 7.11 (0.49) 8 (30.3) 7.11 (0.49) 1-1/8 to 2 inch Standard surface- mounted es- cutcheons, or recessed with the Micromatic® Model E-1, E- 2, or E-3 Recessed Escutcheon See Footnotes 6 and 9 See Foot- note 7 --8 (2.4) 14 X 14 (4.3 X 4.3) 10 (37.9) 11.11 (0.77) 10 (37.9) 11.11 (0.77) 15 X 15 (4.6 X 4.6) 12 (45.4) 16 (1.10) 12 (45.4) 16 (1.10) 16 X 16 (4.9 X 4.9) 13 (49.2) 18.8 (1.29) 13 (49.2) 18.8 (1.29) Footnotes 1 Part number shown is the base part number. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 4 For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. 5 Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union. 6 Approved Finishes are: Brass, Chrome, White Polyester, and Black Polyester 8. 7 Meets New York City requirements, effective July 1, 2008. 8 Other paint colors are available on request with the same C-UL-US-EU listings as the standard finish colors. 9 Approved finish is Electroless Nickel PTFE (ENT). ENT is C-UL-US-EU Listed as corrosion resistant. ENT is available with standard surface-mounted escutcheons or the Micromatic Model E-1 Recessed Escutcheon. In Dry Sauna Only P2904.4.2 System Design Flow Rate Worst Case 38.6 PSI 80 PSI; 9.7 PSI; 1" Service, 17 + 5 GPM, <40' Length 2.0 PSI;1" Meter @ 17 + 5 GPM N/A 15.2 PSI; 35' Elevation Difference to highest system sprinkler head. 14.5 PSI; worst case VK484 sidewall Added 5 GPM to design flow for water service pipe and water meter pressure loss due to dwellings sharing a water tap and service pipe up to meter(s). Per Table P2904.6.2(1) footnote C and Table P2904.6.2(2) footnote B. * * * LEFT UNIT WATER MAIN 1" WATER METER IN PIT 1" POLY SDR 9 CTS UNDERGROUND1" COPPER <40' 1" PEX DISTRIBUTION PIPING, 84 LF TO MOST REMOTE HEAD, TOTAL 141' FROM METER TO MOST REMOTE HEAD, 35' ELEVATION DIFFERENCE TO HIGHEST HEAD. LEFT UNIT = 57' UNDERGROUND RIGHT UNIT = 54' UNDERGROUND RIGHT UNIT 1" PEX DISTRIBUTION PIPING, 102 LF TO MOST REMOTE HEAD, TOTAL 156' FROM METER TO MOST REMOTE HEAD, 30' ELEVATION DIFFERENCE TO HIGHEST HEAD. P2904 MULTIPURPOSE SYSTEM - PRESCRIPTIVE DESIGN SHUT-OFF VALVE WITH DRAIN SHUT-OFF VALVE WITH DRAIN 12/06/22 Residential Lead Free Flat Concealed Sprinkler, Pendent Model RC-RES K-Factor: 3.0 • SIN: SS8361 C US NSF/ANSI/CAN 61 & 372 Table A. NFPA 13D & 13R Wet Pipe Hydraulic Design Criteria for Model SS8361 For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R or 13 as applicable. Maximum Coverage Area(a) Ft. x Ft. (m x m) Maximum Spacing Ft. (m) Ordinary Temperature Rating 162˚F (72˚C) Intermediate Temperature Rating 205˚F (96˚C)Deflector to Ceiling Installation Type Minimum Spacing Ft. (m)Flow(b) GPM (LPM) Pressure(b) PSI (bar) Flow(b) GPM (LPM) Pressure(b) PSI (bar) 12 x 12 (3.7 x 3.7) 12 (3.7) 9 (34.1) 9.0 (0.62) 9 (34.1) 9.0 (0.62) Smooth Ceilings 3/8 to 7/8 Inches. Beamed Ceilings per NFPA 13D, 13R or 13. Installed in beam 3/8 to 7/8 inches below bottom of beam. Concealed 8 (2.4) 14 x 14 (4.3 x 4.3) 14 (4.3) 11 (41.6) 13.4 (0.92) 11 (41.6) 13.4 (0.92) (2 x 9 gpm = 18 gpm) Residential Lead Free Flat Concealed Sprinkler, Pendent Model RC-RES K-Factor: 4.9 • SIN: SS8464 C US NSF/ANSI/CAN 61 & 372 Table A. NFPA 13D & 13R Wet Pipe Hydraulic Design Criteria for Model SS8464 For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R or 13 as applicable. Maximum Coverage Area(a) Ft. x Ft. (m x m) Maximum Spacing Ft. (m) Ordinary Temperature Rating 162˚F (72˚C) Intermediate Temperature Rating 205˚F (96˚C)Deflector to Ceiling Installation Type Minimum Spacing Ft. (m)Flow(b) GPM (LPM) Pressure(b) PSI (bar) Flow(b) GPM (LPM) Pressure(b) PSI (bar) 12 x 12 (3.7 x 3.7) 12 (3.7) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) Smooth Ceilings 3/8 to 7/8 Inches. Beamed Ceilings per NFPA 13D, 13R or 13. Installed in beam 3/8 to 7/8 inches below bottom of beam. Concealed 8 (2.4) 14 x 14 (4.3 x 4.3) 14 (4.3) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 16 x 16 (4.9 x 4.9) 16 (4.9) 13 (49.2) 7.0 (0.48) 13 (49.2) 7.0 (0.48) 18 x 18 (5.5 x 5.5) 18 (5.5) 17 (64.4) 12.0 (0.83) 17 (64.4) 12.0 (0.83) 20 x 20 (6.1 x 6.1) 20 (6.1) 21 (79.5) 18.4 (1.27) 21 (79.5) 18.4 (1.27) {162°F (72°C) Sprinkler with 140°F (60°C) Cover Plate {162°F (72°C) Sprinkler with 140°F (60°C) Cover Plate Rev 19.1 WATER MAIN @ 92 PSI 1" BADGER METER 29 LF 1" COPPER 1" FORD ANGLE DUAL CK SHUTOFF VALVE AND DRAIN 1" ZURN 70XL PRV SHUTOFF VALVE AND DRAIN 1" ZURN 70XL PRV 1" POLY SDR9 CTS (54' UG TO RIGHT UNIT) 1" P O L Y S D R 9 C T S (5 7 ' U G T O L E F T U N I T ) LEFT UNIT RIGHT UNIT 84 LF DISTRIBUTION PIPING TO FURTHEST HEAD 3/4" OR 1" CPVC (IPS) OR 1" PEX ~MAX 35' ELEVATION DIFFERENCE TO HIGHEST HEAD 102 LF DISTRIBUTION PIPING TO FURTHEST HEAD 3/4" OR 1" CPVC (IPS) OR 1" PEX ~MAX 30' ELEVATION DIFFERENCE TO HIGHEST HEAD Running Subtotal Psup 92 92 minus PLsvc (18 + 5 gpm, 86LF) 24.25 67.75 minus PLm (18 + 5 gpm, 1", actual) 1 66.75 minus PLd-DCV (18+5 gpm, 1", actual) 6 60.75 minus PLd-PRV (18 gpm, 1", actual) 7.5 53.25 minus PLe (35', 15.2psi) 15.2 38.05 minus PLs (VK484, 14.5psi) 14.5 23.55 Pt Max 367 LF 1" CPVC @23.55 psi Max 111 LF 1" PEX @ 23.55 psi Max 122 LF 3/4" CPVC @ 23.55 psi 1" CPVC or PEX OK for farthest sprinkler = 84 LF Left, 102 LF Right 3/4" CPVC OK for farthest sprinkler = 84 LF Left, 102 LF Right Option A, Worst P(t) = 1 Tap, 1 Meter, 1 Dual Check, Split Water Service Pipe after meter, Individual PRV's for each unit. Allowable length of sprinkler from service valve to farthest sprinkler (18 gpm) Psvc=Water Service Pipe includes shared 1" copper to meter (29 LF) and individual 1" poly to each service valve (57 LF), 18 + 5 = 23 GPM 12/20/22 - Revised calculations with new pressure and device data, updated schematic, provided information on concealed heads replacing originally proposed VK470 and VK 468. FS4.0 FIRE SPRINKLER 04/01/22 TECHNICAL DATA FREEDOM® RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) Form No. F_061011 19.02.21 Rev 19.1 Page 3 of 5 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval ChartViking VK470, 3.0 K-Factor Residential Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to the current editions of NFPA 13, 13R or 13D Sprinkler Base Part Number 1 SIN NPT Thread Size Nominal K-Factor Maximum Water Working Pressure Overall Length Inches mm U.S.metric 2 Inches mm 17147 VK470 1/2 15 3.0 43.2 175 psi (12 bar)2-1/4 58 Max. Coverage Area 4 Ft.X Ft. (m X m) Ordinary Temp Rating (155 °F/68 °C) Intermediate Temp Rating (175 °F/79 °C)Deflector to Ceiling Installation Type Listings and Approvals 3 Minimum Spacing Ft. (m)Flow 4 GPM (L/min) Pressure 4 PSI (bar) Flow 4 GPM (L/min) Pressure 4 PSI (bar) 5 NYC NSF 12 X 12 (3.7 X 3.7) 8 (30.3) 7.11 (0.49) 8 (30.3) 7.11 (0.49) 1-1/8 to 2 inch Standard surface- mounted es- cutcheons, or recessed with the Micromatic® Model E-1, E- 2, or E-3 Recessed Escutcheon See Footnotes 6 and 9 See Foot- note 7 --8 (2.4) 14 X 14 (4.3 X 4.3) 10 (37.9) 11.11 (0.77) 10 (37.9) 11.11 (0.77) 15 X 15 (4.6 X 4.6) 12 (45.4) 16 (1.10) 12 (45.4) 16 (1.10) 16 X 16 (4.9 X 4.9) 13 (49.2) 18.8 (1.29) 13 (49.2) 18.8 (1.29) Footnotes 1 Part number shown is the base part number. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 4 For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. 5 Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union. 6 Approved Finishes are: Brass, Chrome, White Polyester, and Black Polyester 8. 7 Meets New York City requirements, effective July 1, 2008. 8 Other paint colors are available on request with the same C-UL-US-EU listings as the standard finish colors. 9 Approved finish is Electroless Nickel PTFE (ENT). ENT is C-UL-US-EU Listed as corrosion resistant. ENT is available with standard surface-mounted escutcheons or the Micromatic Model E-1 Recessed Escutcheon. In Dry Sauna Only P2904.4.2 System Design Flow Rate Worst Case 38.6 PSI 80 PSI; 9.7 PSI; 1" Service, 17 + 5 GPM, <40' Length 2.0 PSI;1" Meter @ 17 + 5 GPM N/A 15.2 PSI; 35' Elevation Difference to highest system sprinkler head. 14.5 PSI; worst case VK484 sidewall Added 5 GPM to design flow for water service pipe and water meter pressure loss due to dwellings sharing a water tap and service pipe up to meter(s). Per Table P2904.6.2(1) footnote C and Table P2904.6.2(2) footnote B. * * * LEFT UNIT WATER MAIN 1" WATER METER IN PIT 1" POLY SDR 9 CTS UNDERGROUND1" COPPER <40' 1" PEX DISTRIBUTION PIPING, 84 LF TO MOST REMOTE HEAD, TOTAL 141' FROM METER TO MOST REMOTE HEAD, 35' ELEVATION DIFFERENCE TO HIGHEST HEAD. LEFT UNIT = 57' UNDERGROUND RIGHT UNIT = 54' UNDERGROUND RIGHT UNIT 1" PEX DISTRIBUTION PIPING, 102 LF TO MOST REMOTE HEAD, TOTAL 156' FROM METER TO MOST REMOTE HEAD, 30' ELEVATION DIFFERENCE TO HIGHEST HEAD. P2904 MULTIPURPOSE SYSTEM - PRESCRIPTIVE DESIGN SHUT-OFF VALVE WITH DRAIN SHUT-OFF VALVE WITH DRAIN FS5.0 SIGNAGE TECHNICAL DATA PENDENT SPRINKLER VK470 (K3.0) Form No. F_061011 19.02.21 Rev 19.1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval ChartViking VK470, 3.0 K-Factor Residential Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to the current editions of NFPA 13, 13R or 13D Sprinkler Base Part Number 1 SIN NPT Thread Size Nominal K-Factor Maximum Water Working Pressure Overall Length Inches mm U.S.metric 2 Inches mm 17147 VK470 1/2 15 3.0 43.2 175 psi (12 bar)2-1/4 58 Max. Coverage Area 4 Ft.X Ft. (m X m) Ordinary Temp Rating (155 °F/68 °C)Intermediate Temp Rating (175 °F/79 °C)Deflector to Ceiling Installation Type Listings and Approvals 3 Minimum Spacing Ft. (m)Flow 4 GPM (L/min) Pressure 4 PSI (bar) Flow 4 GPM (L/min) Pressure 4 PSI (bar) 5 NYC NSF 12 X 12 (3.7 X 3.7)8 (30.3)7.11 (0.49)8 (30.3)7.11 (0.49) 1-1/8 to 2 inch Standard surface-mounted es-cutcheons, or recessed with the Micromatic® Model E-1, E- 2, or E-3 Recessed Escutcheon See Footnotes 6 and 9 See Foot-note 7 --8 (2.4) 14 X 14 (4.3 X 4.3)10 (37.9)11.11 (0.77)10 (37.9)11.11 (0.77) 15 X 15 (4.6 X 4.6) 12 (45.4) 16 (1.10) 12 (45.4) 16 (1.10) 16 X 16 (4.9 X 4.9)13 (49.2)18.8 (1.29)13 (49.2)18.8 (1.29) Footnotes 1 Part number shown is the base part number. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 4 For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. 5 Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union. 6 Approved Finishes are: Brass, Chrome, White Polyester, and Black Polyester 8. 7 Meets New York City requirements, effective July 1, 2008. 8 Other paint colors are available on request with the same C-UL-US-EU listings as the standard finish colors. 9 Approved finish is Electroless Nickel PTFE (ENT). ENT is C-UL-US-EU Listed as corrosion resistant. ENT is available with standard surface-mounted escutcheons or the Micromatic Model E-1 Recessed Escutcheon. P2904.4.2 System Design Flow Rate Worst Case 38.6 PSI 80 PSI; 9.7 PSI; 1" Service, 17 + 5 GPM, <40' Length 2.0 PSI;1" Meter @ 17 + 5 GPM * * SIGNAGE 232 South Link Lane, P.O. Box 2044 Â Fort Collins, Colorado 80522 Â Phone (970) 493-2044 Â Fax (970) 493-1801 12/19/2022 RE: Static water distribution main pressure in the area of 1026 Linden Gate Ct, Fort Collins CO Dear ELCO Customer, It has been found that the static water distribution main pressure in the area of 1026 Linden Gate Ct, Ft Collins CO, has historically fluctuated between approximately 92 – 97 psi. If there are any questions please call the office at 970-493-2044 Thank you Alex Ainsworth Cross Connection & Regulatory Specialist East Larimer County Water District Ford Check Valves, Retrosetters and Cut-in Check Valves The Ford Meter Box Co., Inc.775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 260/563-3171 FAX: 1-800-826-3487 Overseas FAX: 260/563-0167 http://www.fordmeterbox.com Section I 3/2002 Ford Cartridge Dual Check Valves are approved by the American Society of Sanitary Engineering and meet or exceed all the requirements of ASSE Standard #1024 - 1994. Water pressure head loss through the checks is lower than the maximum allowed by ASSE, insuring adequate delivery to your customers. Excellent corrosion resistance is provided by the use of stainless steel and acetal plastic working parts and a body cast from AWWA standard 85-5-5-5 brass. The unique angle design of the Ford Angle Cartridge Dual Check Valve (U.S. PAT NO. 5148828) features a removable “O” ring sealed cap at the top of the valve. This allows easy in-line access to the dual check assemblies for maintenance, inspection or replacement. As an added measure of protection, the Ford Angle Cartridge design will deter backflow even if one of the cartridge assemblies is removed from the valve body. Ford Cartridge Dual Check Valves are available in in-line accessible angle and straight styles. They can be an integral part of a Ford Coppersetter, Pit Setter or Iron Yoke. See Catalog Sections F, FA and E. Ford Dual Check Valves are intended for service use as stipulated by ASSE-1024. Cartridge Style Dual Check Valves Pressure Drop - 5/8" x 3/4" and 3/4" Cartridge Dual Check Valves Pressure Drop - 1" Cartridge Dual Check Valves 70 60 50 40 30 20 10 0 70 60 50 40 30 20 10 0 PRESSURE DROP POUNDS PER SQUARE INCH PRESSURE DROP POUNDS PER SQUARE INCH 3/4" HHCH - IN-LINE ACCESSIBLE STRAIGHT CARTRIDGE DUAL CHECK VALVE 3/4" HHCA - IN-LINE ACCESSIBLE ANGLE CARTRIDGE DUAL CHECK VALVE 3/4" HHC - STRAIGHT CARTRIDGE DUAL CHECK VALVE 51015202530 FLOW RATE / GALLONS PER MINUTE ASSE STANDARD 1024 = 10 PSI MAXIMUM AT 15 GPM ASSE STANDARD 1024 = 10 PSI MAXIMUM AT 25 GPM 1" HHCA - IN-LINE ACCESSIBLE ANGLE CARTRIDGE DUAL CHECK VALVE 1" HHC - STRAIGHT CARTRIDGE DUAL CHECK VALVE 10 15 20 25 30 40 50 FLOW RATE / GALLONS PER MINUTE See page 13 for 2" Dual Check Pressure Drop Chart. 23gpm Rev. F Date: 11/19 Document No. REG-70XL Product No. Model 70XL Patent zurn.com/patents Model 70XL Water Pressure Reducing Valve Page 1 of 2 Zurn Industries, LLC | Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada | Zurn Industries Limited 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, 877-892-5216 www.zurn.com 70XL WILKINS AC 70XL WILKINS B DD B AC Application Ideal for use where Lead-Free* valves are required. Designed for installation on potable water lines to reduce high inlet pressure to a lower outlet pressure. The unitized replaceable cartridge reduces time involved with cleaning and maintenance. The direct acting integral bypass design prevents buildup of excessive system pressure caused by thermal expansion. The balanced piston design enables the regulator to react in a smooth and responsive manner to changes in system flow demand, while at the same time, providing protection from inlet pressure changes. Standards Compliance • ASSE® Listed 1003 • IAPMO® Listed • CSA® Certified • City of Los Angeles Approved • Meets the requirements of NSF/ANSI/CAN 61* *(0.25% MAX. WEIGHTED AVERAGE LEAD CONTENT) Materials Body and bell Cast bronze, ASTM B 584 Seat Stainless Steel, 300 series Stem & sleeve Stainless Steel, 300 series Elastomers Buna nitrile, FDA (CFR) 21, 177.2600 EPDM, FDA (CFR) 21, 177.2600 Strainer screen Stainless Steel, 300 series Features Sizes: 3/4", 1" Maximum working water pressure 300 psi Maximum working water temperature 140°F Reduced pressure range 25 psi to 75 psi Factory preset 50 psi Threaded connections (FNPT) ANSI B1.20.1 Copper connections (FC) ANSI B16.22 CPVC tailpiece: Max. hot water temp. 180°F @ 100 psi Cold water rated temp. 73.4°F @ 400 psi Options (Suffixes can be combined) c - standard with single union FNPT connection and 20 mesh strainer screen c C - with FC (copper sweat) union connection c DM - double male meter tailpiece connection (3/4); 1" National Hose Thread fits 5/8" x 3/4" and 3/4" water meters (no union included) c DU - with double union FNPT connection c P - tapped & plugged for gauge c G - tapped & plugged with gauge c SC - sealed cage bell housing and stainless steel adjusting screw c SS - sealed cage bell housing with stainless steel adjusting screw and spring c CPVC - CPVC tailpiece connection c LP - low pressure outlet 10-35 psi available in 3/4" single union, & 3/4" double union c CM - with male copper sweat union connection c DUPF - with Z-Bite™ push fit tailpiece connection 250 psi max pressure c DUPR - with Z-Press™ press fit tailpiece connection 250 psi max pressure Accessories c Repair kit c Water thermal expansion tank (Model XT) c Special in-line spacer nipple (34-70DUSPC & 1-70DUSPC) c In-line strainer screen for DUSPC ( SCR) c Water hammer arrester (Model 1250XL) c Z-Bite™ push fit Tailpiece kit (TPKXLPF) 250 psi max pressure c Z-Press™ press fit Tailpiece kit (TPKXLPR) 250 psi max pressure SIZE CONNECTIONS DIMENSIONS (approximate)WEIGHTABCD in.mm in.mm in.mm in.mm in.mm lbs.kg. 3/4 20 SINGLE UNION 4 5/8 117 6 152 1 25 2 3/4 70 2.9 1.3 3/4 20 DOUBLE UNION 6 152 6 152 1 1/8 29 2 3/4 70 3.0 1.4 1 25 SINGLE UNION 5 127 6 11/16 170 1 25 3 3/8 86 4.1 1.9 1 25 DOUBLE UNION 5 7/8 149 6 11/16 170 1 1/8 29 3 3/8 86 4.5 2.0 Dimensions & Weights (do not include pkg.) NSF/ANSI/CAN 61 Flow Characteristics Page 2 of 2 Zurn Industries, LLC | Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada | Zurn Industries Limited 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, 877-892-5216 www.zurn.com FLOW RATES (GPM) FA L L O F F ( P S I G ) 0 5 10 15 0203040 69 104 0.61.3 2.5 FA L L O F F ( k p a ) FLOW RATES (l/s) MODEL 70XL 3/4" & 1" (STANDARD & METRIC) 35 20 138 10 1.9 3/4" (20mm) 1" (25mm) 5 15 25 35 0.30.9 1.62.2 Typical Installation Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted in accordance with the manufacturer’s instructions and the latest edition of the Uniform Plumbing Code. The assembly shall be installed with sufficient side clearance for testing and maintenance. The Model 70XL may be installed in any position. If installed in a pit, vault or indoors, specify the “SC” sealed cage option. Multiple installations are recommended for wide demand variations or where the desired pressure reduction is more than 4 to 1 (i.e.: 200 psi inlet reduced to 50 psi outlet). CAUTION: Anytime a reducing valve is adjusted, a pressure gauge must be used downstream to verify correct pressure setting. Do not bottom adjustment bolt on bell housing. Typical Installation Specifications The Pressure Reducing Valve shall be certified to NSF/ANSI/CAN 61, of the direct-acting type, and ASSE® 1003 Listed. The integral bypass check valve main body and bell housing shall be cast bronze (ASTM B 584). The pressure reducing valve shall be of the balanced piston design and shall reduce pressure in both flow and no-flow conditions using an adjusting bolt. All internal parts shall be corrosion resistant and included in a replaceable cartridge. The bronze bell housing shall be threaded to the body and shall not require the use of ferrous screws. The Pressure Reducing Valve shall be a ZURN WILKINS Model 70XL. DIRECTION OF FLOW MODEL 975XL2 BACKFLOW PREVENTER MODEL SXL STRAINER WATER METER HOSE BIBB MODEL 70XL REGULATOR MODEL XT EXPANSION TANK WATER HEATER MODEL TP1100A RELIEF VALVE MODEL 850XL BALL VA LVE "Flow curves are based on a 50 psi pressure diႇerential 18 gpm ESM-DS-00041-EN-09 (November 2022) E-Series® Ultrasonic Meter Cold Water Engineered Polymer Meter, 5/8, 5/8 x 3/4, 3/4, and 1 inch Product Data Sheet DESCRIPTION The E-Series® Ultrasonic meter uses solid-state technology in a compact, totally encapsulated, weatherproof, and UV-resistant housing, suitable for residential and commercial applications. Electronic metering provides information—such as rate of flow and reverse flow indication—and data not typically available through traditional, mechanical meters and registers. Electronic metering eliminates measurement errors due to sand, suspended particles and pressure fluctuations. The Ultrasonic 5/8, 5/8 × 3/4, 3/4, and 1 inch meters feature: • Minimum extended low-flow rate lower than typical positive displacement meters. • Simplified one-piece electronic meter and register that are integral to the meter body and virtually maintenance free. • Sealed, non-removable, tamper-protected meter and register. • Easy-to-read, 9-digit LCD display presents consumption, rate of flow, reverse-flow indication, and alarms (empty pipe, temperature, exceeding max flow, sensor error, reverse flow, suspected leak, 30 day no usage, end of life). • High resolution industry standard ASCII encoder protocol sends alarms and data to ORION® Cellular endpoints and BEACON® SaaS* suite to establish a smart water solution. The Ultrasonic meter is available with an in-line connector for easy connection and installation to AMR/AMI endpoints. It is also available with a flying lead for field splice connection. * Software as a Service APPLICATIONS Use the Ultrasonic meter for measuring potable cold water in residential, commercial and industrial services. The meter is also ideal for non-potable, irrigation water applications or less than optimum water conditions where small particles exist. E-Series Ultrasonic meters meet and exceed ANSI/AWWA C715 standards. The meters comply with the lead-free provisions of the Safe Drinking Water Act, are certified to NSF/ANSI/CAN Standards 61 and 372 and carry the NSF-61 mark on the housing. OPERATION & PERFORMANCE As water flows into the measuring tube, ultrasonic signals are sent consecutively in forward and reverse directions of flow. Velocity is then determined by measuring the time difference between the measurement in the forward and reverse directions. Total volume is calculated from the measured flow velocity using water temperature and pipe diameter. The LCD display shows total volume and alarm conditions and can toggle to display rate of flow. In the normal temperature range of 45…122° F (7…50° C), the Ultrasonic “new meter” consumption measurement is accurate to: • ±1.5% over the normal flow range • ±3.0% from the extended low flow range to the minimum flow value CONSTRUCTION E-Series Ultrasonic meters feature an engineered polymer, lead-free meter housing, an engineered polymer and stainless steel metering insert, a meter-control circuit board with associated wiring, LCD, and battery. Wetted elements are limited to the pressure vessel, polymer/stainless steel metering insert and the transducers. The electronic components are housed and fully potted within a molded, engineered polymer enclosure, which is permanently attached to the meter housing. The transducers extend through the polymer housing and are sealed by O-rings. The metering insert holds the stainless steel ultrasonic reflectors in the center of the flow area, enabling turbulence-free water flow through the tube and around the ultrasonic signal reflectors. The metering insert’s patented design virtually eliminates chemical buildup on the reflectors, ensuring long-term metering accuracy. METER INSTALLATION The meter is completely submersible and can be installed using horizontal or vertical piping, with flow in the up direction. The meter will not measure flow when an ”empty pipe” condition is experienced. An empty pipe is defined as a condition when the flow sensors are not fully submerged. E-Series® Ultrasonic Meter BEACON, E-Series and ORION are registered trademarks of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. © 2022 Badger Meter, Inc. All rights reserved. www.badgermeter.com SMART WATER IS BADGER METER Legacy Document Number: ESM-T-12-EN PRESSURE LOSS CHART Rate of Flow in gallons per minute (gpm) 2 3 4 5 6 7 8 ess u re D r op i n P S I 0 1 2 3 4 5 6 7 8 9 10 11 12 13 0 10 20 40 50 60 Pre ss u r e Dr op i n P S I 30 Flow Rate in ŐƉŵ 5/8 x 3/4 in. 5/8 in. 3/4 in. 1 in. ACCURACY CHARTS Rate of Flow in gallons per minute (gpm) 5/8 IN. METER 5/8 × 3/4 IN. METER 95 96 97 98 99 100 101 102 103 104 105 0.01 0.1 1 10 100 Ac c u r a c y i n P e r c e n t Flow Rate in gpm 3/4 IN. METER 1 IN. METER 95 97 99 101 103 105 0.1 1 10 100 Acc ur ac y i n P e r c e n t Flow Rate in gpm 23gpm 12/20/22 - Added Elco static pressure letter and information on added devices including pressure loss data.