Loading...
HomeMy WebLinkAbout4450 DENROSE COURT - Filed MA-MINOR AMENDMENT -City of Fort Collins Zoning 281 N. College Ave. Fort Collins, CO 80524 Phone 970.416.2745 zoning@fcgov.com Micro Amendment – Planning & Zoning Department *THIS FORM IS FOR OFFICE USE ONLY* Instructions: This form is to document “micro” changes to an approved development plan. Planner or Zoning Inspector needs to fill out form and save document along any attachments to S:drive folder: S:\CDNS\CUSTOMER_ADMIN_SERVICES\Final Docs - Scanning\Micro Amendments Naming convention: project/subdivision name, project number (ex: Feeder Supply, FDP130039.pdf) Examples of micro amendments (use your best judgement, these changes should not have large impacts): Minor landscape changes Screening for mechanical equipment Building paint color change Relocating handicap parking spaces Moving internal pedestrian walkways/sidewalks Description of the change and reason(s) for the request: _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ Project name & Number:____________________________________________________________________________ Building Permit (if applicable): _______________________________________________________________________ Project Location (Street Address): ____________________________________________________________________ Requester’s Name (s): _______________________________________________________________________________ Telephone: __________________________ Email:________________________________________________________ ☐Attachment included City Approval: ___________________________________________________________ Date: __________________________________________ 4450 Denrose Ct B2303514 4450 Denrose Ct Don Bernholtz 970-682-4927 don@vfla.com 4 Add new AC ground units on west side of property. Will be screened by 6' tall fencing. 7.17.23 MA230077 SS SS WW W WWWWWWW WW ELECF.O. CONTROL IRR CONTROL IRR M CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR F.O. F.O. ELEC W W HY D CONTROL IRR CONTROL IRR ELEC TRAFFIC VAULT CONTROL IRR CONTROL IRR CONTROL IRR F.O. F.O. H Y D M E E E E E E FO FO FO FO FO FO FO FO E E E E E E E E EF O FO FO FO FO FO FO FO FO FO FO FO F O E E E E E E E E E E G G G G G G G G G G G G G G G G G G G G G G FO FO FO FO FO FO FO FO FO FO FO E E W W W W W W WW W W W W W W W W W W W W W W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS EXISTING BUILDING FOOTPRINT NEW EMPLOYEE PAVILION SIX CAR PARKING GARAGE (FUTURE PHASE) THREE CAR PARKING CANOPY (FUTURE PHASE) LOT 1 INTERCHANGE BUSINESS PARK LOT 4 INTERCHANGE BUSINESS PARK DENRO S E C O U R T (60' PU B L I C R . O . W . 26'-0" EAE 26'-0" EAE 3'-9" ACCESS EASEMENT R25'-0" R25'-0" 9'-0" 5'-0" 9'-0" 11'-0" STORMWATER EASEMENT 20'-0" PSCO EASEMENT 16'-6" EASEMENT 20'-0" UE 5'-6" NEW WALK 30'-0" 20'-7" 7'-8" 17'-6" 20'-0" 20'-0" 26'-0" EAE 26'-0" EAE 20'-0" EAE 6'-8" PARKWAY 6'-7" PARKWAYNEW 10'-1" WALK 5'-0" R25'-0" EXISTING UTILITY EASEMENT 17'-0" 17'-0" 17'-0" 17'-0" 9'-0" 9'-0" 9'-0" 9'-0" 19'-1" EXISTING DIMENSION 9'-0"9'-0" 9'-0" 9'-0" EXISTING TREE TO REMAIN EXISTING TREE TO REMAIN EXISTING TREE TO REMAIN EXISTING TREE TO REMAIN EXISTING POLE LIGHT TO REMAIN NEW RAMP EXISTING POLE LIGHT TO REMAIN EXISTING POLE LIGHT TO REMAIN NEW RAMP NEW PARKING LOT STRIPING NEW CURB & GUTTER NEW CURB & GUTTER NEW 5' DETACHED SIDEWALK ALONG PROPERTY FRONTAGE NEW LANDSCAPING NEW RAMP NEW TELESCOPE OBSERVATION ENCLOSURE PROPERTY LINE EXISTING SOFT TRAIL TO REMAIN FL 18" RCP PIPE FL 12" PVC PIPE NEW PAINTED CROSSWALKEXISTING LIGHT POLE TO REMAIN NEW DRIVEWAY RAMP NEW EMPLOYEE PATIO AREA EXISTING TREE TO REMAIN EXISTING BIKE RACK TO REMAIN EXISTING TRASH ENCLOSURE TO REMAIN (2) NEW OVERHEAD DOORS EXISTING LIGHT POLE TO REMAIN NEW DRIVEWAY RAMP EXISTING POLE LIGHT TO REMAIN NEW CHASE RE: CIVIL 19'-10" EAE 23'-8" EAE 23'-5" EAE SYMBOL DESCRIPTION QTY EXISTING CONCRETE TO REMAIN 3,798 SF 20 SITE DEVELOPMENT SYMBOL DESCRIPTION QTY NEW LANDSCAPED AREAS 13,456 SF NEW CONCRETE WALKS 3,626 SF REFERENCE NOTES SCHEDULE W W W G G E E FO FO SS SS OHE OHE OHE M = EXISTING WATER UTILITY = EXISTING STORM DRAIN UTILITY = EXISTING GAS UTILITY = PROPERTY BOUNDARY = DRAINAGE OR UTILITY EASEMENT =EXISTING TREE/SHRUBS TO REMAIN = 100 YEAR FEMA FLOOD PLAIN = EXISTING FIBER OPTIC UTILITY = EXISTING ELECTRIC UTILITY = EXISTING SEWER SERVICE = EXISTING OVERHEAD ELECTRIC UTILITY = MITIGATION TREE DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ka t y T h o m p s o n La y o u t : 2 S i t e P l a n Pr i n t e d O n : 7/ 2 1 / 2 0 2 1 1 1 : 1 9 A M Fi l e N a m e : 2 S i t e P l a n . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com NUMERICA CORPORATION Jeff Poore 5042 Technology Parkway STE 100, Fort Collins, CO 80528 ENGINEER OWNER'S REP NORTHERN ENGINEERING Danny Weber 301 N. Howes St. Suite #100 Fort Collins, CO 80521 p. 970.221.4158 SCHROYER RESOURCES LLC Steve Schroyer p. 970.481.5505 OWNER RIPLEY DESIGN INC. Katy Thompson 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 LANDSCAPE ARCHITECT ARCHITECT VFLA ARCHITECTS Don Bernholtz 419 Canyon Ave. Suite 200 p. 970-224-1191 SITE PLAN MINOR AMENDMENT 4450 DENROSE 7/21/2021MINOR AMENDMENT #303 6/16/2021MINOR AMENDMENT #202 5/12/2021MINOR AMENDMENT01 FORT COLLINS, CO KT AG R21-023 1 OF 4 NORTH 0 10 20 40 SCALE: 1"=20'-0" GROSS SITE AREA 144,154 SQ. FT. (3.31 ACRES) BUILDING FLOOR AREA BREAKDOWN (SQ. FT.) GENERAL OFFICE 8,918 WORKSHOP 23,034 TOTAL:31,952 PARKING REQUIREMENTS EXISTING REQUIRED PROPOSED STANDARD SPACE 78 30 3 ACCESSIBLE SPACE 4 2 56 GARAGE SPACE 0 0 9 TOTAL PARKING SPACES:82 32 68 BIKE PARKING REQUIREMENTS EXISTING REQUIRED PROPOSED FIXED SPACE 7 6 7 ENCLOSED SPACE 0 2 2 TOTAL BIKE PARKING SPACES:7 8 9 PARKING NOTES: 1.PARKING CALCULATION IS BASED ON GENERAL OFFICE USE PARKING REQUIREMENTS (1 PER 1,000 SQUARE FEET) PER LUC ARTICLE 3.2.2(K)(2)(a). BIKE PARKING NOTES: 1.PARKING CALCULATION IS BASED ON GENERAL OFFICE USE PARKING REQUIREMENTS (1 PER 4,000 SQUARE FEET WITH A MINIMUM OF 20% ENCLOSED) PER LUC ARTICLE 3.2.2(C)(4)(b). LAND USE TABLE ZONING C-G (GENERAL COMMERCIAL) NOTES 1.ANY FUTURE CHANGES TO SITE OR EXTERIOR BUILDING LIGHTING, INCLUDING BULB CHANGES OR FIXTURE RETROFITS, NEED TO TO COMPLY WITH CURRENT CODE. LEGAL DESCRIPTION LOT 1, INTERCHANGE BUSINESS PARK, AMD LOT 2 & 3 (20030131354), FTC LEGEND Existing conditions DW DW CLR. 3' - 0" EVAP. UNIT 4' - 0" CLR. 3' - 0" CLEAR 4' - 0 " EV A P . U NI T 7' - 8 " 10 ' - 9 " 10 ' - 9 " EV A P . U NI T 7' - 8 " CL E A R 4' - 0 " (+/-) 3' - 8" EXISTING 20' - 0" (+/-) EXISTING PROPERTY LINE EXISTING 12" STORM PIPE EXISTING 8" STORM PIPE NEW UNIT- MOUNTED METAL PANEL SCREEN WALL & SUPPORT BRACKETS, BY VENDOR. NEW CONC. PIER FOUNDATIONS (HYDRAULIC EXCAVATION, RE: STRUCT.) EXISTING FIRE ACCESS DOOR NEW EVAPORATIVE COOLER UNIT ON STEEL FRAME AND CONC. PIER FOUNDATIONS PER STRUCTURAL. NEW UNIT- MOUNTED METAL PANEL SCREEN WALL & SUPPORT BRACKETS, BY VENDOR. NEW EVAPORATIVE COOLER UNIT ON STEEL FRAME AND CONC. PIER FOUNDATIONS PER STRUCTURAL. EXISTING WEST EXTERIOR WALL NEW OVERHEAD DUCTWORK NEW OVERHEAD DUCTWORK EXISTING WALL LIGHT SEP. FROM FNDN. 6' - 4" (+/-) EX I S T I N G ( V . I . F . ) 5' - 3 1 / 2 " FACE OF BUILDING CENTERLINE CL EXISTING CONC. LANDING EXISTING TREE EXISTING TREE STEEL PAINT FINISH FOR SUPPORT FRAME: STEEL TO BE PRIMED USING SHERWIN WILLIAMS MACROPOXY 646 PRIMER WITH TWO FINISH COATS OF SHERWIN WILLIAMS ACROLON 218 POLYURETHANE. COLOR: GRAY. CRITICAL ROOT ZONE (9' RADIUS) CRITICAL ROOT ZONE (7' RADIUS) 4 ASI-2 4 ASI-2 4 ASI-2 A1.1. 2 A3.1.1 WATER & POWER PROVIDED PER MECHANICAL & ELECTRICAL DRAWINGS; & PER PREVIOUS HUMIDIFIERS INSTALLATION NEW EVAPORATIVE COOLER UNITS, SEE ENLARGED PLAN EXISTING WAREHOUSE EXISTING OFFICES CODE DATA 2021 I.B.C. W/ LOCAL AMENDMENTS 2021 I.F.C. 2021 I.E.C.C. OCCUPANCY GROUP(S): CONTRUCTION TYPE: SPRINKLER SYSTEM: OCCUPANCY SEPARATION: OCC. GROUPS: B, F-1 & S-1: 62,000 S.F. (F-1 MOST RESTRICTIVE) ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE - TABLE 504.3 ALLOWABLE AREA FACTOR PER TABLE 506.2 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE - TABLE 504.4 OCC. GROUPS: B, F & S (SPRINKLED) ALLOWABLE BUILDING HEIGHT = 75' - 0" EXISTING BUILDING HEIGHT = 37' - 6" OCC. GROUPS: B,F-1 & S-1 (SPRINKLED) ALLOWABLE NUMBER OF STORIES = 3 STORIES (F-1 & S-1) EXISTING NUMBER OF STORIES = 1 STORY 1ST FLOOR - 1ST FLOOR UNENCLOSED EXTERIOR AREAS - TOTAL - EXISTING BUILDING AREA 31,950 SF 393 SF 32,343 SF B, F-1, S-1 II -B NFPA TYPE 13 SPRINKLERS NO PRIMARY STRUCTURAL FRAME BEARING WALLS EXTERIOR BEARING WALLS INTERIORS NON BEARING WALLS & PARTITIONS INTERIOR FLOOR CONSTRUCTION & SECONDARY MEMBERS ROOF CONSTRUCTION & SECONDARY MEMBERS FIRE RESISTANCE RATINGS FOR BUILDING ELEMENTS BASED ON CONSTRUCTION TYPE - IBC TABLE 601 0 HR 0 HR 0 HR 0 HR 0 HR 0 HR APPLICABLE CODES AND STANDARDS JURISDICTION: APPLICABLE CODES: CITY OF FORT COLLINS -BUILDING SERVICES DEPARTMENT POUDRE FIRE AUTHORITY 2021 IBC -INTERNATIONAL BUILDING CODE 2021 IECC -INTERNATIONAL ENERGY CONSERVATION CODE 2021 IFC -INTERNATIONAL FIRE CODE 2021 IFGC -INTERNATIONAL FUEL GAS CODE 2021 IMC -INTERNATIONAL MECHANICAL CODE 2021 IPC -INTERNATIONAL PLUMBING CODE 2020 NEC -NATIONAL ELECTRIC CODE 2021 IEBC -INTERNATIONAL EXISTING BUILDING CODE CITY OF FORT COLLINS –BUILDING CODE AMENDMENTS CITY OF FORT COLLINS –LAND USE CODE SHEET INDEX A1.1 A3.1 S0.1 S1.1 M0.1 M2.1 M8.1 E1.1 E2.1 PHASE 2 -PLAN AT EVAP COOLERS PHASE 2 -ELEVATION & DETAILS -EVAP COOLERS GENERAL NOTES, ABBREVIATIONS, SHEET LIST PARTIAL FOUNDATION AND ROOF FRAMING PLAN NOTES, LEGEND, DETAIL, AND DRAWING INDEX PHASE 2 -FIRST FLOOR MECHANICAL PLAN MECHANICAL SCHEDULES PHASE 2 NOTES, SCHEDULES & ONE-LINE DIAGRAM PHASE 2 HVAC POWER PLAN 419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191 108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710 www.VFLA.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. COPYRIGHT: SHEET ISSUANCES DESCRIPTION DATE N O T F O R C O N S T R U C T I O N F O R R E F E R E N C E O N L Y A R C H I T E C T U R E + I N T E R I O R S CIVIL ENGINEER: NORTHERN ENGINEERING LANDSCAPE ARCHITECT: RIPLEY DESIGN, INC. STRUCTURAL ENGINEER: LARSEN STRUCTURAL DESIGN MECHANICAL ENGINEER: INTEGRATED MECHANICAL, LLC ELECTRICAL ENGINEER: ELECTRICON ELECTRICAL ENGINEERING 4450 DENROSE - NUMERICA PERMIT SET 6/ 2 / 2 0 2 3 4 : 3 1 : 4 9 P M 6/2/2023 4:31:49 PM C: \ U s e r s \ d o n . b e r n h o l t z \ D o c u m e n t s \ R e v i t U s e r F i l e s \ 4 45 0 D e n r o s e T F R 2 0 C e n t r a l M o d e l _ d o n N S 9 D V . r v t A1.1. PHASE 2 -PLAN AT EVAP COOLERS 4450 DENROSE COURT FORT COLLINS, CO 2021-15 SCALE:1/4" = 1'-0" 2 ENLARGED PLAN @ EVAP COOLERS AREA SCALE:1" = 20'-0" 1 KEY PLAN FOR EVAP COOLER PLACEMENT SCALE:3 AXON VIEW -EVAP COOLERS PERMIT SET 2023-03-29 (4) ASI-4 MICRO AMENDMENT 2023-06-022 N O T F O R C O N S T R U C T I O N F O R R E F E R E N C E O N L Y N O T F O R C O N S T R U C T I O N F O R R E F E R E N C E O N L Y 07/14/202103/29/2023 FIRST FLOOR 100' -0" EXISTING FIRE ACCESS DOOR NEW PAINTED DUCTS ATTACHED TO FACE OF BUILDING. COLOR TO MATCH WHITE OF (E) BUILDING NEW SCREENED EVAPORATIVE COOLING UNIT. SCREEN PER VENDOR. PREFINISH AS SELECTED BY ARCHITECT DURING SUBMITTAL PROCESS. NEW SCREENED EVAPORATIVE COOLING UNIT EXISTING BUILDING EXISTING BUILDING DUCT PENETRATIONS CENTERED THROUGH EXISTING OPENINGS: COVER, SEAL & INSULATE ANNULAR SPACES. 2 A3.1. EXISTING BUILDING 12' - 0" 27 ' - 1 0 " ( A P P R O X . , V I F ) 6' - 0 " 6' - 0 " SCREEN HEIGHT ABOVE GRADE4 ASI-2 4 ASI-2 5.1 ANCHORS PER STRUCT. INTO (E) PRECAST WALL ASSEMBLY INFILL OF EXISTING OPENING: • CEMENTIOUS PANEL SIDING: B.O.D.: 5/16" ALLURA SMOOTH VERTICAL PANEL (PREFIN/ J-TRIM AT HEAD & JAMBS WITH SEALANT). PRIMED, AND PAINTED WITH 2 COATS EXTERIOR 100% ACRYLIC LATEX; OVER, • TYVEK COMMERCIAL WRAP 'D' AIR & WEATHER BARRIER (AWB). INSTALL PER MFR'S INSTRUCTIONS USING MFR'S APPROVED ACCESSORIES. LAP INTO OPNG.'S PER MFR'S INSTRUCTIONS. • 1/2" DENSGLASS EXTERIOR FIBERGLASS MAT GYPSUM SHEATHING; OVER, • 6-INCH GALV. STEEL STUD FRAMING (GAUGE & SPACING PER STRUCTURAL), WITH MIN. R-21 FIBERGLASS OR MINERAL WOOL BATT INSUL. IN STUD CAVITIES. COMPLETELY FILL ALL CAVITIES WITH NO VOIDS OR GAPS. • 6 MIL POLY VAPOR/AIR BARRIER AT INTERIOR FACE OF STUDS. • 1/2" OR 5/8" GYPSUM BOARD AT INTERIOR, FINISHED WITH 2 COATS ACRYLIC LATEX PAINT (COLOR TO MATCH (E) WALLS. INSULATED DUCT PER MECHANICAL DOCUMENTS PREFIN. BASE FLASHING WITH DRIP EDGE AT FULL PERIMETER OF DUCT PENETRATION, FILL ANNULAR SPACE WITH COMPRESSIBLE FILLER STRIP, AND CAP EXTERIOR AND INTERIOR ENDS WITH ELASTOMERIC SEALANT (B.O.D.: SIKAFLEX®-1A). EXISTING(E) PRECAST WALLS 123' - 7" (FIN.FLR. @ 100'-0") B.O.(E) OPENING (APPROX., V.I.F.) 128' - 7" T.O.(E) OPENING (APPROX., V.I.F.) V.I.F. (E) SOLID CONCRETE AROUND OPENING UPON DEMOLITION OF (E) FANS. LAP. AWB OVER T.O. FLASHING PRIME & PAINT EXPOSED STEEL, TYP. SECURE DUCTWORK PER MECHANICAL & STRUCTURAL DOCUMENTS1/ 2 " SECURE DUCTWORK PER MECHANICAL & STRUCTURAL DOCUMENTS 419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191 108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710 www.VFLA.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. COPYRIGHT: SHEET ISSUANCES DESCRIPTION DATE N O T F O R C O N S T R U C T I O N F O R R E F E R E N C E O N L Y A R C H I T E C T U R E + I N T E R I O R S CIVIL ENGINEER: NORTHERN ENGINEERING LANDSCAPE ARCHITECT: RIPLEY DESIGN, INC. STRUCTURAL ENGINEER: LARSEN STRUCTURAL DESIGN MECHANICAL ENGINEER: INTEGRATED MECHANICAL, LLC ELECTRICAL ENGINEER: ELECTRICON ELECTRICAL ENGINEERING 4450 DENROSE - NUMERICA PERMIT SET 6/ 2 / 2 0 2 3 4 : 3 3 : 4 8 P M 6/2/2023 4:33:48 PM C: \ U s e r s \ d o n . b e r n h o l t z \ D o c u m e n t s \ R e v i t U s e r F i l e s \ 4 45 0 D e n r o s e T F R 2 0 C e n t r a l M o d e l _ d o n N S 9 D V . r v t A3.1. PHASE 2 -ELEVATION & DETAILS -EVAP COOLERS 4450 DENROSE COURT FORT COLLINS, CO 2021-15 SCALE:3/32" = 1'-0"1 ELEVATION -WEST EVAP UNITS SCALE:1 1/2" = 1'-0"2 DETAIL @ EVAP DUCT PENETRATION PERMIT SET 2023-03-29 (4) ASI-4 MICRO AMENDMENT 2023-06-022 N O T F O R C O N S T R U C T I O N F O R R E F E R E N C E O N L Y N O T F O R C O N S T R U C T I O N F O R R E F E R E N C E O N L Y 07/14/202103/29/2023 STRUCTURAL GENERAL NOTES Project: 4450 Denrose Tenant Finish Larsen Structural Design Job Number: 2448 DESIGN LOADS: International Building Code; IBC 2021 Edition, except as noted Risk Category:Table 1604.5 II Standard Roofs: Ground Snow: Pg 30 psf (used for drifting calculations) Flat Roof Snow:Pf 30 psf (Min.) Snow Exposure Factor: Ce ASCE 7-16 Table 7.3-1 1.0 Snow importance Factor: Is ASCE 7-16 Table 1.5-2 1.0 Snow Thermal Factor: Ct ASCE 7-16 Table 7.3-2 1.0 Lateral: Wind ASCE 7-16 Directional Procedure 3 Second Gust Velocity V_ult = 115 mph Building Category Enclosed Internal Pressure Coefficient ASCE 7-16 Table 26.13-1 GCpi= ±0.18 Exposure C Seismic Importance Factor:Ie ASCE 7-16 Table 1.5-2 1.0 Spectral Response Acceleration Coefficient Short Period Ss 0.179 g SDS 0.191 g One Second S1 0.054 g SD1 0.086 g Soils Site Class D Design Category Table 1613.2.5(1) & (2)B FOUNDATION DESIGN: Refer to soils report no. #FC-2857 by CTL/Thompson, dated September 15, 2003. Soils engineer shall verify soil conditions and types during excavation and prior to concrete placement. --Footings--- Design of footings is based on: Maximum allowable bearing pressure:3,000 psf Minimum dead load pressure:800 psf Bear footings on undisturbed natural soils or suitable compacted material as directed by the geotechnical engineer. Bottom of exterior footings to bear a minimum of 36" below final exterior grade for frost protection. STRUCTURAL CONCRETE: Design is based on "Building Code Requirements for Structural Concrete"(ACI 318-14). Concrete work shall conform to "Standard Specifications for Structural Concrete” (ACI 301-16). Structural concrete shall have the following properties: Intended Exposure f’c, (psi)Maximum Maximum Entrained Cement Use Category 28 day w/cm Aggregate Air (±1.5%)Type Foundations F1/S0/W0/C1 3,500 0.55 1”Stone 6%I/II Concrete mix designs shall be submitted to the engineer of record no less than 15 working days prior to the commencement of pouring. Slump of concrete shall be specified by the concrete sub-contractor to provide adequate workability and finishing of the concrete being placed. No concrete admixture containing calcium chloride shall be permitted in any concrete. Detailing, fabrication, and placement of reinforcing steel shall be in accordance with the "Guide to Presenting Reinforcing Steel Design Details (ACI 315R-18). Reinforcing bars shall conform to ASTM A615, Grade 60, reinforcement to be welded shall be ASTM 706 grade 60 reinforcing. Reinforcing bars shall be spliced a minimum of 67 bar diameters. Except as noted on the drawings, concrete protection for reinforcement in cast-in-place concrete shall be as follows: a. Cast against and permanently exposed to earth 3" b. Exposed to earth or weather: #6 through #18 bars 2" #5 bar, W31 or D31 wire, and smaller 1-1/2" c. Not exposed to weather or in contact with ground: Slabs, walls, joists: #11 bar and smaller 3/4" Beams, columns: Primary reinforcement 1-1/2" Stirrups, ties, spirals 1-1/2" Anchor bolts and rods for beam and column-bearing plates shall be placed with setting templates. Concrete shall not be placed until reinforcing and embedded items have been inspected by a qualified special inspector employed by the owner in accordance with IBC Section 1704.4. STRUCTURAL ERECTION AND BRACING REQUIREMENTS: The structural drawings illustrate the completed structure with elements in their final positions, properly supported and braced. These construction documents contain typical and representative details to assist the contractor. Details shown apply at all similar conditions unless otherwise indicated. Although due diligence has been applied to make the drawings as complete as possible, not every detail is illustrated, nor is every exceptional condition addressed. All proprietary connections shall be installed in accordance with the manufacturers' recommendations. All work shall be accomplished in a workmanlike manner and in accordance with the applicable code and local ordinances. The general contractor is responsible for coordination of all work, including layout and dimension verification, materials coordination, shop drawing review, and the work of subcontractors. Any discrepancies or omissions discovered in the course of the work shall be immediately reported to the architect for resolution. Continuation of work without notification of discrepancies relieves the architect and engineer from all consequences. Unless otherwise specifically indicated, the drawings do not describe methods of construction. The contractor, in the proper sequence, shall perform or supervise all work necessary to achieve the final completed structure, and to protect the structure, workmen, and others during construction. Such work shall include, but not be limited to, bracing, shoring for construction equipment, shoring for excavation, formwork, scaffolding, safety devices and programs of all kinds, support and bracing for cranes and other erection equipment. Do not backfill against basement or retaining walls until supporting slabs and floor framing are in place and securely anchored, unless adequate bracing is provided. Temporary bracing shall remain in place until all floors, walls, roofs and any other supporting elements are in place. The architect and engineer bear no responsibility for the above items, and observation visits to the site do not in any way include inspection of them. SHOP DRAWINGS: Construction Documents are copyrighted and shall not be copied for use as erection plans or shop details. Use of Larsen Structural Design's electronic files as base for shop drawings requires prior approval by Larsen Structural Design, signed release of liability by subcontractor, and deletion of Larsen Structural Design’s name and Logo from all sheets so used. The General Contractor and his subcontractors shall submit in writing any requests to modify the plans or specifications. All shop and erection drawings shall be checked and stamped by the General Contractor prior to submission for Engineer's review. Unchecked submittals will be returned without review. Furnish one (1) electronic copy of shop and erection drawings to the Structural Engineer for review prior to fabrication for: • Concrete mix designs • Reinforcing steel • Structural steel Submit in a timely manner to permit ten (10)working days for review. Shop drawings submitted for review do not constitute "request for change in writing" unless specific suggested changes are clearly marked. In any event, such changes by means of the shop drawing submittal process become the responsibility of the one initiating such change. STRUCTURAL STEEL: Structural steel shall be detailed, fabricated, and erected in accordance with the "Specification for Structural Steel Buildings" (AISC 360-16) and the "Code of Standard Practice for Steel Building and Bridges" (AISC 303-16), by the American Institute of Steel Construction (AISC). Structural steel wide flange beams shall conform to ASTM A992. Other rolled shapes, including plates, channels, and angles shall conform to ASTM A36. Hollow structural section (HSS) tube shapes shall conform to ASTM A500, Grade B, 46 ksi yield. Except as noted, framed beam connections shall be bearing-type with 3/4" diameter, snug tight, A325-N bolts, detailed in conformance with the Structural Drawings and the "Steel Construction Manual" by AISC, 15th Edition. Install bolts in accordance with AISC "Specification for Structural Joints Using ASTM A325 or A490 Bolts", 2004. Anchor rods shall conform to ASTM F1554, Grade 36 (or high strength Gr 55 or Gr 105 as noted), with weldability supplement S1. Welding shall be done by a certified welder in accordance with AISC and AWS specifications and recommendations using E70-electrodes. Where not specifically noted, minimum weld shall be 3/16”fillet by length of contact edge. All post-installed anchors shall have current International Code Council Evaluation Service (ICC-ES) reports and shall be installed in accordance with the manufacturer's requirements. Chemical anchors shall be approved epoxy or similar adhesive type and shall have current ICC-ES Report. Where base material is not solid, approved screen tubes shall be used. Grout beneath column base and beam-bearing plates shall be minimum 28-day compressive strength of 7,500 psi, approved non-metallic,non-shrink, when tested in accordance with ASTM C1107 Grade B or C at a flow cone fluid consistency of 20 to 30 seconds. LETTERS OF CONSTRUCTION COMPLIANCE: The General Contractor shall determine from the local building official at the time the building permit is obtained whether any letters of construction compliance will be requested from the Structural Engineer. The Contractor shall notify the engineer about all such requirements in writing before the start of construction. One-week advance notice shall be given when requesting site visits necessary as the basis for the compliance letter. INSPECTIONS AND REVIEWS: All site soils related work and footing excavations prior to placing forms, as well as site drainage, shall be reviewed by the project geotechnical engineer. Normal reviews by Local Building Department. Notify 48 hours prior to required review. Required special inspections per I.B.C. Section 1705 by an approved special inspector retained by owner: * Concrete: Observation of reinforcing, embeds, and forms prior to placement of concrete and observation during placement of concrete as well as taking and testing of specimens. Refer to Section 1705.3 and Table 1705.3 of the I.B.C. * Steel: Periodic and continuous inspections of steel frame joint details. Refer to Section 1705.2 and Table 1705.2.2 of the I.B.C, and Tables N5.4-1 thru N5.4-3 and N5.6-1 thru N5.6-3 of the AISC 360-16. * Grading, Excavation and Placement of Fills: Observation during grading, earthwork excavations and placement of fills, as well as testing for required compaction of fills. Approved agencies shall provide written documentation to the building official demonstrating the competence and relevant experience or training of the special inspectors who will perform the special inspections and testing prior to and during construction as required per IBC 2018 Section 1704.2.1. Duties and responsibilities of the special inspector shall be to observe and/or test the work assigned and outlined above for conformance with the approved construction documents. All discrepancies shall be brought to the immediate attention of the contractor for correction. The special inspector shall furnish regular reports to the building official, the engineer and architect of record, and other designated persons. Progress reports for continuous inspection shall be furnished weekly. Individual reports of periodic inspections shall be furnished within one week of inspection dates. The reports shall note uncorrected deficiencies, correction of previously reported deficiencies, and changes to the approved construction documents authorized by engineer of record. The special inspector shall submit a final signed report within 10 days of the final special inspection stating whether the work requiring special inspection was, to the best of the inspector's knowledge and belief, in conformance with the approved construction documents and the applicable workmanship provisions of the International Building Code. Work not in compliance shall be noted in the report. FIELD VERIFICATION OF EXISTING CONDITIONS: Contractor shall thoroughly inspect and survey existing structure to verify conditions that affect the work shown on the drawings. Contractor shall report any variations or discrepancies to the Architect before proceeding. Contract documents have been prepared using limited site observations. During construction, the contractor may encounter existing conditions which are not now known or are variance with project documentation (discovery). contractor shall notify the engineer of all conditions not per the contract Documents. examples include: • Sizes or dimensions other than those shown. • Damage or deterioration to materials or components. • Conditions of instability or lack of support. • Items noted as existing on the drawings but not found in the field include, but are not limited to: Contractor shall prepare dimensional drawings of all discovered items. Contractor shall field verify all existing structural conditions prior to submitting shop drawings. Contractor shall make allowance for the resolution of such discoveries in the construction schedule. ABBREVIATIONS: B/???BOTTOM OF ELEMENT C.F.M.F.COLD FORMED METAL FRAMING C.L.CENTERLINE CLR.CLEAR COL.COLUMN DEFL.DEFLECTION FTG.FOOTING G.B.GRADE BEAM G.L.GRID LINE H.A.S.HEADED ANCHOR STUDS (E)EXISTING ELEMENT E.O.D.EDGE OF ROOF DECK E.O.S.EDGE OF SLAB LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL MAX.MAXIMUM MIN.MINIMUM O.H.OPPOSITE HAND O.H.OVERHANG (C&C LOAD TABLE) SIM.SIMILAR SL.SLOPED STL.STEEL T/???TOP OF ELEMENT T&B TOP AND BOTTOM TYP.TYPICAL W.T.S.WELDED THREADED STUDS REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION TYPE CONTINUOUS PERIODIC REFERENCED STANDARD a IBC REFERENCE 1. INSPECT REINFORCEMENT, INCLUDING PRESTRESSING TENDONS, AND VERIFY PLACEMENT.--X ACI 318: CH. 20, 25.2, 25.3, 26.6.1-26.6.3 1908.4 2.REINFORCING BAR WELDING: a. VERIFY WELDABILITY OF REINFORCING BARS OTHER THAN ASTM A706; b. INSPECT SINGLE-PASS FILLET WELDS, MAXIMUM 5/16"; AND c. INSPECT ALL OTHER WELDS. --x AWS D1.4 ACE 318: 26.6.4 -- 3. INSPECT ANCHORS CAST IN CONCRETE --X ACI 318: 17.8.2 -- 5. VERIFY USE OF REQUIRED DESIGN MIX.--X ACI 318: CH. 19, 26.4.3, 26.4.4 1904.1, 1904.2, 1908.2, 1908.3 6. PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF CONCRETE. X -- ASTM C 172 ASTM C 31 ACI 318: 26.5, 26.12 1908.10 7. INSPECT CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES. X --ACI 318: 26.5 1908.6, 1908.7, 1908.8 8. VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES.--X ACI 318: 26.5.3-26.5.5 1908.9 9. INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED. X ACI 318: 26.11.1.2(b)-- TABLE RECREATED FROM IBCTABLE 1705.3 4. INSPECT ANCHORS POST-INSTALLED IN HARDENED CONCRETE MEMBERS.b a. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARDLY INCLINED ORIENTATIONS TO RESIST SUSTAINED TENSION LOADS. b. MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOT DEFINED IN 4.a. X X ACI 318: 17.8.2.4 -- x x ACI 318: 17.8.2 a. WHERE APPLICABLE , SEE SECTION 1705.12, SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE. b. SPECIFIC REQUIREMENTS FOR SPECIAL INSPECTION SHALL BE INCLUDED IN THE RESEARCH REPORT FOR THE ANCHOR ISSUED BY AN APPROVED SOURCE IN ACCORDANCE WITH 17.8.2 IN ACI 318, OR OTHER QUALIFICATION PROCEDURES. WHERE SPECIFIC REQUIREMENTS ARE NOT PROVIDED, SPECIAL INSPECTION REQUIREMENTS SHALL BE SPECIFIED BY THE REGISTERED DESIGN PROFESSIONAL AND SHALL BE APPROVED BY THE BUILDING OFFICIAL PRIOR TO THE COMMENCEMENT OF THE WORK. -- REQUIRED SPECIAL INSPECTIONS AND TESTS OF SOILS TYPE CONTINUOUS TABLE RECREATED FROM IBC TABLE 1705.6 PERIODICALLY 1. VERIFY MATERIAL BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY. --X 2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL.--X 3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS.--X 4. VERIFY USE OF PROPER MATERIAL, DENSITIES AND LIFT THICKNESSES DURING PLACEMENT AND COMPACTION OF CONTROLLED FILL. X -- 5. PRIOR TO PLACEMENT OF CONTROLLED FILL, OBSERVE SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY. --X REQUIRED VERIFICATION AND INSPECTION OF STEEL CONSTRUCTION -BOLTING VERIFICATION AND INSPECTION CONTINUOUS PERIODIC 1. INSPECTION TASKS PRIOR TO BOLTING: a. MANUFACTURER'S CERTIFICATIONS AVAILABLE FOR FASTENER MATERIALS X -- b. FASTENERS MARKED IN ACCORDANCE WITH ASTM REQUIREMENTS • PERIODIC: OBSERVE THESE ITEMS ON A RANDOM BASIS. OPERATIONS NEED NOT BE DELAYED PENDING THESE INSPECTIONS. • CONTINUOUS: PERFORM THESE TASKS FOR EACH WELDED JOINT OR MEMBER. • OBSERVATION OF WELDING OPERATIONS AND VISUAL INSPECTION OF IN-PROGRESS AND COMPLETED WELDS SHALL BE THE PRIMARY METHOD TO CONFIRM THAT THE MATERIALS, PROCEDURES AND WORKMANSHIP ARE IN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS. • FOR STRUCTURAL STEEL, ALL PROVISIONS OF AWSD1.1/D1.1M SHALL APPLY. • FOR STRUCTURES IN RISK CATEGORY III/IV (ASCE 7 TABLE 1.5-1), ULTRASONIC TESTING SHALL BE PERFORMED ON ALL COMLETE-JOINT-PENETRATION GROOVE WELDS SUBJECT TO TRANSVERSELY APPLIED TENSION LOADING IN BUTT, T-AND CORNER JOINTS, IN MATERIALS 5/16" (8 mm) THICK OR GREATER. • FOR STRUCTURES IN RISK CATEGORY I/II (ASCE 7 TABLE 1.5-1), ULTRASONIC TESTING SHALL BE PERFORMED ON 10% OF COMPLETE-JOINT-PENETRATION GROOVE WELDS SUBJECT TO TRANSVERSELY APPLIED TENSION LOADING IN BUTT, T-AND CORNER JOINTS, IN MATERIALS 5/16" (8 mm) THICK OR GREATER. • THERMALLY CUT SURFACES OF ACCESS HOLES SHALL BE TESTED USING MAGNETIC PARTICLE TESTING OR PENETRANT TESTING WHEN THE FLANGE THICKNESS EXCEEDS 2" (20 mm) FOR ROLLED SHAPES, OR WHEN THE WEB THICKNESS EXCEEDS 2" (50 mm) FOR BUILT-UP SHAPES. ANY CRACK SHALL BE DEEMED UNACCEPTABLE REGARDLESS OF SIZE OR LOCATION. • ALL NON-DESTRUCTIVE TESTING OF WELDED JOINTS SHALL BE DOCUMENTED. • SEE AISC 360-10 CHAPTER N FOR ADDITIONAL WELD INSPECTION REQUIREMENTS. • SEE AISC 360-10 CHAPTER N FOR ADDITIONAL BOLT INSPECTION REQUIREMENTS. • INSPECTION SHALL OCCUR DURING THE PLACEMENT OF ANCHOR RODS AND OTHER EMBEDMENTS SUPPORTING STRUCTURAL STEEL FOR COMPLIANCE WITH THE CONSTRUCTION DOCUMENTS, INCLUDING DIAMETER, GRADE, TYPE AND LENGTH OF THE ANCHOR ROD OR EMBEDDED ITEM, AND THE EXTENT OR DEPTH OF EMBEDMENT INTO THE CONCRETE. • FABRICATED STEEL AND ERECTED STEEL FRAMES, AS APPROPRIATE, SHALL BE INSPECTED FOR COMPLIANCE WITH THE DETAILS SHOWN ON THE CONSTRUCTION DOCUMENTS, INCLUDING BRACES, STIFFENERS, MEMBER LOCATIONS AND PROPER JOINT DETAIL APPLICATION. TABLE RECREATED FROM AISC 360-10 TABLES N5.6-1, N5.6-2, N5.6-3. d. PROPER BOLTING PROCEDURE SELECTED FOR JOINT DETAIL e. CONNECTING ELEMENTS, INCLUDING THE APPROPRIATE FAYING SURFACE CONDITION AND HOLE PREPARATION, IF SPECIFIED, MEET APPLICABLE REQUIREMENTS c. PROPER FASTNERS SELECTED FOR THE JOINT DETAIL (GRADE, TYPE, BOLT LENGTH IF THREADS ARE EXCLUDED FROM SHEAR PLANE) f. PRE-INSTALLATION VERIFICATION TESTING BY INSTALLATION PERSONNEL OBSERVED AND DOCUMENTED FOR FASTENER ASSEMBLIES AND METHODS USED g. PROPER STORAGE PROVIDED FOR BOLTS, NUTS, WASHERS, AND OTHER FASTENET COMPONENTS 2. INSPECTION TASKS DURING BOLTING: a. FASTENER ASSEMBLIES, OF SUITABLE CONDITION, PLACED IN ALL HOLES AND WASHERS (IF REQUIRED) ARE POSITIONED AS REQUIRED b. JOINT BROUGHT TO THE SNUG-TIGHT CONDITION PRIOR TO THE PRETENSIONING OPERATION d. FASTENERS ARE PRETENSIONED IN ACCORDANCE WITH THE RCSC SPECIFICATION, PROGRESSING SYSTEMATICALLY FROM THE MOST RIGID POINT TOWARD THE FREE EDGES c. FASTENER COMPONENT NOT TURNED BY THE WRENCH PREVENTED FROM ROTATION 3. INSPECTION TASKS AFTER BOLTING: a. DOCUMENT ACCEPTANCE OR REJECTION OF BOLTED CONNECTIONS --X --X --X --X --X --X --X --X --X --X X -- 419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191 108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710 www.VFLA.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. COPYRIGHT: SHEET ISSUANCES DESCRIPTION DATE A R C H I T E C T U R E + I N T E R I O R S CIVIL ENGINEER: NORTHERN ENGINEERING LANDSCAPE ARCHITECT: RIPLEY DESIGN, INC. STRUCTURAL ENGINEER: LARSEN STRUCTURAL DESIGN MECHANICAL ENGINEER: INTEGRATED MECHANICAL ELECTRICAL ENGINEER: ELECTRICON ELECTRAL ENGINEERING 320 MAPLE STREET SUITE 120 FORT COLLINS, COLORADO 80521 ERIC@LARSENSD.COM 970-568-3355 WWW.LARSENSD.COM 3/ 2 9 / 2 0 2 3 4 : 5 8 : 2 3 P M 3/29/2023 4:58:23 PM M: \ L S D \ L S D J o b s \ 2 4 4 8 4 4 5 0 D e n r o s e \ R e v i t \ 2 4 4 8 _ 4 4 5 0 D EN R O S E _ S T R U C T U R A L _ C E N T R A L _ R V T 2 0 . r v t S0.1 GENERAL NOTES, ABBREVIATIONS, SHEET LIST 4450 DENROSE - NUMERICA 4450 DENROSE COURT FORT COLLINS, CO PERMIT SET LSD-2448 STRUCTURAL SHEET LIST SHEET NO.SHEET NAME S0.1 GENERAL NOTES, ABBREVIATIONS, SHEET LIST S1.1 PARTIAL FOUNDATION AND ROOF FRAMING PLAN PERMIT SET 2023-03-29 03/29/2023 5.1 5.1 5 C A 3 S1.1 99' - 6" 12 2 ' - 1 1 " 99' - 6" 3' - 8"3' - 2 1/2" 3' - 8"3' - 2 1/2" (N) EVAPORATIVE COOLER PER MECH. (1,000 LBS) (N) EVAPORATIVE COOLER PER MECH. (1,000 LBS) 43 ' - 4 " 7' - 2 " 21 ' - 1 1 " 7' - 2 " 43 ' - 4 " W8 X 1 8 W8X18 W8 X 1 8 W8X18 W8X18 W8 X 1 8 W8 X 1 8 W8X18 T/PIER TYP. T/PIER TYP. EXISTING SLAB-ON-GRADEEXISTING 8" PRECAST WALL T/(E) S.O.G. 100'-0"TYP.3 S1.1TYP.18"Ø FND. TYP. OF (4) 18"Ø FND. TYP. OF (4) VERIFY DIMS. WITH MECH. UNIT CUT SHEET VERIFY DIMS. WITH MECH. UNIT CUT SHEET 5.1 5.1 5 C A RIDGE (E ) P A R A L L E L C H O R D S C I S S O R J O I S T (E) 60" x 60" WALL BLOCKOUT (E) 60" x 60" WALL BLOCKOUT (N) DUCTWORK PER MECH. ATTACHMENT TO WALL PER MECH. CONTRACTOR (E) JOIST X-BRIDGING TO REMAIN, DO NOT CUT OR MODIFY, TYPICAL FOR ALL BRIDGING THAT MAY EXIST ALONG JOIST (E ) P A R A L L E L C H O R D S C I S S O R J O I S T (E) JOIST X-BRIDGING TO REMAIN, DO NOT CUT OR MODIFY, TYPICAL FOR ALL BRIDGING THAT MAY EXIST ALONG JOIST 4 S1.1 4 S1.1 12 2 ' - 1 1 " 6' - 8"12' - 0" NEW DUCTWORK ON INTERIOR OF BUILDING. SEE MECHANICAL AND ARCHITECTURAL PLANS FOR SIZE AND EXTENTSEVAPORATIVE COOLER PER MECH. 3" C L R . 3' - 0 " M I N . 100' - 8" T/STL. 99' - 6" T/PIER 3" CLR. W8X18 SKIDS OR RAILS PER MECH. UNIT PROVIDER, ALIGN OVER BEAMS ALIGN 1 1/2" 3" 1 1 / 2 " 1/4 1' - 6" Ø 18"Ø FOUNDATION, REINFORCE w/ (4)-#5 VERTICALS AND #3 TIES AT 10" O.C., (2) AT 3" TOP 3/4"Ø F1554 GR. 36 ANCHOR RODS w/ 12" MIN. EMBEDMENT EXTERIOR GRADE SLOPES, V.I.F. 3/4" x 11" SQ. BASE PLATE HSS5x5x1/4 COLUMN w/ 1/4" CAP PLATE TYPICAL OF (4) PER FRAME 3/8" x 4" x 6" SHEAR TAB w/ (2)-3/4"Ø A325 BOLTS, TYP. 1/4 1/4 , TYP. 1-1/2" SHIM & NON-SHRINK GROUT CONTRACTOR NOTE: ALL STEEL SHALL BE PRIMED AND PAINTED AS REQUIRED PER ARCHITECTURAL PLANS ATTACHMENT OF UNIT TO W8 BY OTHERS NEW DUCTWORK PER MECH. (E) 8" PRECAST WALL PANEL 600T125-43 TRACK, TYP. T&B. ATTACH w/ (1)-0.157"Ø x 1-1/4" P.A.F. AT 8" O.C. 600S162-43 STUDS AT 16" O.C. MAX., ATTACH EACH FLANGE w/ (1)-#10 SCREW, TYPICAL 600T125-43 TRACK, TYP. T&B OF DUCTWORK OPENING EQ EQ WALL SHEATHING AND FINISHES PER ARCHITECT NOTES: • TOP OF EXISTING SLAB-ON-GRADE = 100'-0" • TYPICAL TOP OF NEW FOUNDATION = 99'-6", U.N.O. • TYPICAL TOP OF STEEL = 100'-8", U.N.O. • SEE S0.1 FOR GENERAL NOTES • SEE S0.2 FOR SPECIAL INSPECTIONS 5.1 1.1 AA C F E C 5 2 1 KEY PLAN PORTION OF BLDG. SHOWN NOTES: • SEE S0.1 FOR GENERAL NOTES • SEE S0.2 FOR SPECIAL INSPECTION • SEE MECHANICAL AND ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION REGARDING EXTENT OF DUCTWORK 419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191 108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710 www.VFLA.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. COPYRIGHT: SHEET ISSUANCES DESCRIPTION DATE A R C H I T E C T U R E + I N T E R I O R S CIVIL ENGINEER: NORTHERN ENGINEERING LANDSCAPE ARCHITECT: RIPLEY DESIGN, INC. STRUCTURAL ENGINEER: LARSEN STRUCTURAL DESIGN MECHANICAL ENGINEER: INTEGRATED MECHANICAL ELECTRICAL ENGINEER: ELECTRICON ELECTRAL ENGINEERING 320 MAPLE STREET SUITE 120 FORT COLLINS, COLORADO 80521 ERIC@LARSENSD.COM 970-568-3355 WWW.LARSENSD.COM 3/ 2 9 / 2 0 2 3 4 : 5 8 : 2 6 P M 3/29/2023 4:58:26 PM M: \ L S D \ L S D J o b s \ 2 4 4 8 4 4 5 0 D e n r o s e \ R e v i t \ 2 4 4 8 _ 4 4 5 0 D EN R O S E _ S T R U C T U R A L _ C E N T R A L _ R V T 2 0 . r v t S1.1 PARTIAL FOUNDATION AND ROOF FRAMING PLAN 4450 DENROSE - NUMERICA 4450 DENROSE COURT FORT COLLINS, CO PERMIT SET LSD-2448 1/4" = 1'-0"S1.1 1 PARTIAL FOUNDATION PLAN NORTH 1/4" = 1'-0"S1.1 2 PARTIAL ROOF FRAMING PLAN NORTH NORTH 1" = 1'-0"S1.1 3 EVAP. COOLER FOUNDATION AND FRAMING SECTION 1" = 1'-0"S1.1 4 FRAMING SECTION AT DUCT PENETRATION PERMIT SET 2023-03-29 03/29/2023 PLUMBING LEGEND: V G D GRADE CLEANOUT RD ORD W GW HWC HW TW CW CD HOT WATER CIRC. TEMPERED WATER NATURAL GAS PIPING WASTE PIPING VENT PIPING HOT WATER PIPING COLD WATER PIPING PIPE CONTINUATION ROOF DRAIN PIPE OVERFLOW RD PIPE SOLENOID VALVE PIPE CAP UNION CHECK VALVE BALANCE VALVE PRESS. RED. VALVE GATE VALVE GAS COCK BALL VALVE FLOOR CLEANOUT WALL CLEANOUT ROOF DRAIN GREASE WASTE PIPING DRAIN PIPING T & P RELIEF VALVE CONDENSATE PIPING PIPE ELBOW UP PIPE TEE DOWN PIPE TEE UP PIPE ELBOW DOWN PIPE TO BE REMOVED INVERT ELEVATIONI.E. NEW(N) EXISTING(E) RELOCATE(R) HVAC LEGEND: ROUND DUCT (NEW SHADED/EXISTING UNSHADED) RECT TAKE‐OFF W/ DAMPER FROM ROUND MAIN RECT TAKE‐OFF W/ DAMPER FROM RECT MAIN ROUND TAKE‐OFF W/ DAMPER FROM ROUND MAIN ROUND TAKE‐OFF W/ DAMPER FROM RECT MAIN DUCT WITH MOTORIZED DAMPER DUCT WITH COUNTERBALANCED DAMPER RETURN/EXHAUST GRILLE (DUCTED) AIRFLOW PATTERNS THERMOSTAT WITH ZONE TAG FIRE DAMPER TAG FIRE/SMOKE DAMPER WITH DUCT DETECTOR DUCT WITH VOLUME DAMPER RETURN GRILLE (UNDUCTED) DIFFUSER WITH FLEX DUCT F FS RECT DUCT SIZE CHANGE RECT DUCT CHANGE TO ROUND RECT ELBOW UP (SUPPLY) RECT ELBOW UP (NON‐SUPPLY) RECT ELBOW DOWN (SUPPLY) RECT ELBOW DOWN (NO N‐SUPPLY) ROUND ELBOW DOWN ROUND ELBOW UP ROUND ELBOW RECT ELBOW W/ TURNING VANES RECT DUCT (NEW SHADED/EXISTING  UN SHADED) SENSOR WITH ZONE TAG SMOKE DAMPER WITH DUCT DETECTORSD CARBON DIOXIDE SENSOR DEMOLISHED DUCTWORK C Z‐* S Z‐* T Z‐* MVD UNLESS NOTED  OTHERWISE SUPPLY EXHAUST/RETURN 45° SCALE: DUCT TAKE‐OFF DETAIL RECTANGULAR NONE &DQ\RQ$YH6XLWH)RUW&ROOLQV&2_ (DVW/LQFROQZD\&KH\HQQH:<_ ZZZ9)/$FRP '5$:,1*180%(5 352-(&7180%(5 6($/ ,1$662&,$7,21:,7+ 6WUHQJWKLQGHVLJQ6WUHQJWKLQSDUWQHUVKLS 6WUHQJWKLQFRPPXQLW\ 9$8*+7)5<(/$5621$521621$5&+,7(&785(,17(5,256,1& 7+,6'5$:,1*0$<127%(3+272*5$3+('6&$11('75$&('25 &23,(',1$1<0$11(5:,7+2877+(:5,77(13(50,66,212)9)/$ &23<5,*+7 6+((7,668$1&(6 '(6&5,37,21 '$7( A R C H I T E C T U R E + I N T E R I O R S &,9,/(1*,1((5 /$1'6&$3($5&+,7(&7 6758&785$/(1*,1((5 0(&+$1,&$/(1*,1((5 3/80%,1*(1*,1((5 (/(&75,&$/(1*,1((5                   $ 0 $0 0 127(6/(*(1' '(7$,/$1' '5$:,1*,1'(; '(1526( 180(5,&$ '(1526(&2857 )257&2//,16&2 3(50,76(7  3(50,76(7  MECHANICAL DRAWING INDEX SHEET NUMBER SHEET NAME MECHANICAL DRAWING INDEX SHEET NUMBER SHEET NAME M0.1 NOTES, LEGEND, DETAIL, AND DRAWING INDEX M2.1 PHASE 2 ‐ FIRST FLOOR MECHANICAL PLAN M8.1 MECHANICAL SCHEDULES GENERAL MECHANICAL REQUIREMENTS: CODES AND PERMITS WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES, REGULATIONS AND  ORDINANCES. PERMITS NECESSARY FOR PERFORMANCE OF WORK SHALL BE SECURED AND PAID FOR BY THE CONTRACTOR. DRAWINGS AND COORDINATION DRAWINGS FOR MECHANICAL WORK ARE DIAGRAMMATIC IN NATURE, AND ARE NOT INTENDED TO BE SCALED FOR EXACT  MEASUREMENTS NOR TO SERVE AS SHOP DRAWINGS. CHANGES FROM THE PLANS MADE WITHOUT CONSENT OF THE  ENGINEER SHALL RELIEVE THE ENGINEER OF RESPONSIBILITY FOR ALL CONSEQUENCES ARRIVING OUT OF SUCH CHANGES.  INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. WHERE CONDITIONS REQUIRE  REASONABLE CHANGES TO THOSE INDICATED ON THE DRAWINGS, MAKE SUCH CHANGES WITHOUT ADDITIONAL COST TO THE  OWNER. COORDINATE ALL WORK WITH OTHER TRADES. WARRANTY WORKMANSHIP, MATERIALS, EQUIPMENT AND PROPER OPERATION SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR  FROM THE DATE OF FINAL ACCEPTANCE FROM THE OWNER. INITIAL ACCEPTANCE OF WORK SHALL NOT WAIVE THIS  GUARANTEE.  THIS GUARANTEE SHALL NOT INCLUDE NORMAL MAINTENANCE REQUIRED BY THE OWNER AS DESCRIBED IN  EQUIPMENT OPERATION AND MAINTENANCE MANUALS. SUBMITTALS CONTRACTOR SHALL SUBMIT TO THE ARCHITECT/ENGINEER A MINIMUM OF (5) COPIES OF SUBMITTAL BROCHURES FOR  REVIEW. PROVIDE INFORMATION ON ALL MAJOR EQUIPMENT AS LISTED ON DRAWING EQUIPMENT SCHEDULES, AS WELL AS  VALVES, DUCTWORK ACCESSORIES AND TEMPERATURE CONTROL DIAGRAMS AS APPLICABLE. OPERATION AND MAINTENANCE MANUALS CONTRACTOR SHALL FURNISH AT THE COMPLETION OF THE PROJECT (2) COPIES OF COMPLETE OPERATION AND  MAINTENANCE MANUALS TO THE ARCHITECT/ENGINEER FOR REVIEW PRIOR TO TURNOVER TO OWNER.  MANUALS TO BE  BOUND AND INCLUDE INSTALLATION INSTRUCTIONS, REPLACEMENT PARTS LISTS AND MAINTENANCE INFORMATION ON ALL  EQUIPMENT AS DESCRIBED IN THE SUBMITTALS SECTION.  COMPLETED OPERATION AND MAINTENANCE MANUALS ARE TO BE  FORWARDED TO THE OWNER WITHIN 90 DAYS AFTER OWNER BUILDING ACCEPTANCE. PRODUCT SUBSTITUTIONS MANUFACTURER MODEL NUMBERS LISTED ON THE DRAWINGS AND/OR SPECIFICATIONS ARE TO BE CONSIDERED AS THE  BASIS OF DESIGN. WHERE TWO OR MORE ALTERNATE MANUFACTURERS OR MATERIALS ARE LISTED, THE CHOICE OF THESE  SHALL BE OPTIONAL WITH THE CONTRACTOR.  PRIOR TO THE AWARDING OF THE CONTRACT, CONTRACTOR MAY REQUEST A  PROPOSED SUBSTITUTION OF MATERIALS IN WRITING TO THE ARCHITECT/ENGINEER NO LATER THAN SEVEN DAYS PRIOR TO  THE RECEIPT OF BIDS.  THE COST OF ANY CHANGES REQUIRED BY OTHER TRADES, INCLUDING A/E DESIGN, DUE TO THE  USE OF EQUIPMENT AND/OR MATERIALS OTHER THAN THAT OF THE BASIS OF DESIGN SHALL BE PAID BY THE  CONTRACTOR. RECORD DRAWINGS CONTRACTORS SHALL MAINTAIN A COMPLETE AND ACCURATE SET OF MARKED UP DRAWINGS SHOWING ACTUAL LOCATIONS  OF INSTALLED WORK.  THESE DRAWINGS ARE TO BE FORWARDED TO THE OWNER AS PART OF THE OPERATION AND  MAINTENANCE MANUALS AT THE COMPLETION OF THE PROJECT. ACCESS DOORS PROVIDE ALL ACCESS DOORS/PANELS AS REQUIRED FOR ACCESS TO VALVES, DAMPERS, CONTROL DEVICES, FILTERS AND  ANY OTHER ITEMS FOR WHICH ACCESS IS REQUIRED FOR EITHER OPERATION OR SERVICING.  WHERE ACCESS DOORS ARE  TO BE INSTALLED IN ASSEMBLIES REQUIRED TO HAVE A SPECIFIC FIRE RATING, ACCESS DOORS SHALL ALSO BE FIRE  RATED. PIPING AND DUCTWORK SEALANT THROUGH RATED ASSEMBLIES PENETRATIONS SHALL BE SEALED AS REQUIRED IN ACCORDANCE WITH BUILDING AND MECHANICAL CODES TO RESIST THE  PASSAGE OF FLAME AND PRODUCTS OF COMBUSTION IN ORDER TO MAINTAIN THE RESISTANCE RATING OF THE  CONSTRUCTION BEING PENETRATED. PROTECTION OF MATERIALS AND EQUIPMENT CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF ALL WORK, MATERALS, AND EQUIPMENT PROVIDED UNDER THIS  SECTION.  PIPE OPENINGS SHALL BE CLOSED WITH CAPS OR PLUGS TO PREVENT THE ENTRANCE OF DEBRIS DURING  CONSTRUCTION.  ALL DUCTWORK OPENINGS SHALL BE SEALED CLOSED DURING CONSTRUCTION. EQUIPMENT AND PIPING IDENTIFICATION PROVIDE EQUIPMENT LABELS FOR ALL MAJOR EQUIPMENT, INCLUDING BUT NOT LIMITED TO AIR HANDLING SYSTEMS, FANS,  VAV BOXES, CONTROLS, DAMPERS, CONTROL VALVES AND PUMPS. PROVIDE PIPE MARKERS ON CW, HW AND HWC SYSTEMS. LABELS TO BE AT MAXIMUM 8 FEET APART, WITH FLOW DIRECTION  INDICATED, AS APPLICABLE. ADDITIONALLY, PROVIDE LABELING ON POTABLE WATER MANIFOLDS INDICATING PLUMBING FIXTURE SERVED BY THE OUTLET,  AS APPLICABLE. LABELS SHALL BE AFFIXED OR ADHERED PERMANENTLY TO EQUIPMENT.  EQUIPMENT INSTALLED INDOORS TO BE LABELED  WITH EMBOSSING TAPE. EQUIPMENT INSTALLED OUTDOORS TO BE LABELED WITH ENGRAVED PLASTIC LAMINATE SIGNS. PIPE MARKERS TO BE SELF‐ADHESIVE, MANUFACTURED FOR SUCH PURPOSE. STARTERS AND DISCONNECTS EQUIPMENT STARTERS SHALL BE FURNISHED BY THE MECHANICAL CONTRACTOR AND INSTALLED BY THE ELECTRICAL  CONTRACTOR. EQUIPMENT DISCONNECTS SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE  ON THE DRAWINGS.  STARTERS SHALL BE NEMA TYPE, AND SHALL INCLUDE PHASE MONITORING FOR MOTORS 5 HP AND  LARGER. TESTING TESTING SHALL BE PERFORMED ON THE FOLLOWING SYSTEMS SPECIFIED. ALL SYSTEMS LISTED MAY NOT BE INCLUDED IN  PROJECT, REFER TO DRAWINGS FOR APPLICABLE SYSTEMS. SOIL, WASTE AND STORM DRAINAGE PIPING SHALL BE TESTED IN ACCORDANCE WITH APPLICABLE STATE AND LOCAL CODES. DOMESTIC WATER PIPING SHALL BE TESTED AND PROVEN WATERTIGHT UNDER A PRESSURE NOT LESS THAN THE WORKING  PRESSURE OF THE SYSTEM FOR A 24 HOUR PERIOD. DOMESTIC WATER PIPING SYSTEM SHALL BE CHLORINATED AND STERILIZED IN ACCORDANCE WITH REQUIREMENTS OF LOCAL  JURISDICTION. NATURAL GAS PIPING SHALL BE TESTED WITH AN AIR PRESSURE OF MINIMUM TWO TIMES THE DESIGN SYSTEM PRESSURE,  BUT NO LESS THAN 3 PSIG, FOR A PERIOD OF 24 HOURS WITHOUT PRESSURE DROP. BALANCING SYSTEM BALANCING SHALL BE PERFORMED BY A CERTIFIED BALANCING CONTRACTOR. BALANCE ALL SYSTEMS INCLUDING  AIRFLOW TO AND FROM ALL OPENINGS, AND PUMPED WATER SYSTEMS INCLUDING DOMESTIC WATER RECIRCULATION  SYSTEMS AS APPLICABLE.  MAKE ANY ADJUSTMENTS NECESSARY TO RESULT IN CONDITIONS INDICATED AND PROVIDE  READJUSTMENTS TO ITEMS IN REPORT AS MAY BE REQUESTED BY ARCHITECT/ENGINEER.  SUBMIT TWO COPIES OF TEST  AND BALANCE REPORT FOR APPROVAL.  FAN AND PUMP SYSTEMS TO BE BALANCED WITHIN PLUS OR MINUS 5 PERCENT  OF LISTED VALUES.  AIR INLETS AND OUTLETS TO BE BALANCED WITHIN PLUS 10 PERCENT OR MINUS 5 PERCENT OF  LISTED VALUES.  BALANCE REPORT TO INCLUDE: UNIT IDENTIFICATION MANUFACTURER AND NAMEPLATE DATA EQUIPMENT NAMEPLATE AMPERAGE AND ACTUAL AMPERAGE RPM (DESIGN AND ACTUAL) FAN CFM (DESIGN AND ACTUAL) FAN STATIC PRESSURE (DESIGN AND ACTUAL) PUMP GPM (DESIGN AND ACTUAL) PUMP DISCHARGE AND SUCTION PRESSURE REGISTER, GRILLE, DIFFUSER REFERENCE NUMBER AND LOCATION INLET/OUTLET CFM (DESIGN AND ACTUAL) FLOW DEVICE PRESSURE DROP, CFM OR GPM A FINAL BALANCING REPORT SHALL BE PROVIDED TO THE OWNER AFTER COMPLETION OF THE PROJECT. CLEANING AT THE COMPLETION OF WORK, ALL FIXTURES AND EQUIPMENT SHALL BE THOROUGHLY CLEANED AND DELIVERED IN A  CONDITION SATISFACTORY TO THE ARCHITECT.  ALL FILTERS SHALL BE REPLACED WITH NEW PRIOR TO OWNER ACCEPTANCE  OF THE BUILDING. AND GREEN CODE REQUIREMENTS CITY OF FORT COLLINS AMENDMENTS 1 BEFORE OCCUPANCY AND AFTER ALL INTERIOR FINISHES ARE COMPLETE, THE BUILDING IS TO BE FLUSHED OUT (VENTILATED) FOR A PERIOD OF 14 DAYS.  WHERE CONTINUOUS VENTILATION IS NOT POSSIBLE, THE AGGREGATE OF FLUSH‐OUT PERIODS SHALL BE EQUIVALENT TO 14 DAYS.  CONTRACTOR SHALL PROVIDE FLUSH‐OUT REPORTS TO THE BUILDING OFFICIAL UPON COMPLETION OF WORK. CONTRACTOR TO COORDINATE WITH BUILDING OFFICIAL FOR INFORMATION TO BE CONTAINED IN FLUSH‐OUT REPORTS. 2 PROTECT HVAC EQUIPMENT FROM CONSTRUCTION DUST AND DEBRIS.  DO NOT OPERATE HVAC EQUIPMENT DURING CONSTRUCTION AND SEAL ALL DUCT OPENINGS WITH PLASTIC. 3 LOW‐VOLATILE ORGANIC COMPOUND (VOC) DUCT INSULATION ADHESIVE SHALL BE USED: DESIGN POLYMERICS 2501, 2502 OR APPROVED EQUAL. 4 LOW‐VOLATILE ORGANIC COMPOUND (VOC) DUCT SEALANT SHALL BE USED: DESIGN POLYMERICS 1010, 1015 OR APPROVED EQUAL. 5 LOW‐VOLATILE ORGANIC COMPOUND (VOC) FIRE CAULK SHALL BE USED:3M FIRE BARRIER 1C 15WB+, FD 150+, CP 25WB+ OR APPROVED EQUAL. 6 IN ADDITION TO TESTING REQUIREMENTS LISTED IN THE GENERAL MECHANICAL REQUIREMENTS, ALL HEATING, COOLING AND VENTILATION SYSTEMS SHALL BE PERFORMANCE‐TESTED BY AN APPROVED AGENCY AND ADJUSTED TO OPERATE WITHIN DESIGN SPECIFICATIONS.  DOCUMENTATION OF TESTING AND ADJUSTING RESULTS (TAB REPORT) SHALL BE SUBMITTED TO THE BUILDING OFFICIAL PRIOR TO APPROVAL.  COORDINATE WITH BUILDING OFFICIAL FOR LIST OF APPROVED AGENCIES. 7 A CONSTRUCTION WASTE MANAGEMENT PLAN WILL BE IMPLEMENTED REQUIRING RECYCLING OF NONHAZARDOUS CONSTRUCTION DEBRIS.  COORDINATE WITH G.C. FOR RECYCLING OF ITEMS RELATED TO THE MECHANICAL SCOPE OF WORK. 8 EXTERIOR AND INTERIOR LOCAL DESIGN TEMPERATURES (DEG F): ‡WINTER OUTDOOR DESIGN DB..........6 ‡WINTER INDOOR DESIGN DB.............72 ‡SUMMER OUTDOOR DESIGN DB .......91 ‡SUMMER INDOOR DESIGN DB ..........75 ‡SUMMER OUTDOOR DESIGN WB .......62 ‡SUMMER INDOOR DESIGN WB ..........62 ‡CLIMATE ZONE 5B MECHANICAL ENERGY CODE INSULATION NOTES AND 1 THE MECHANICAL DESIGN IS BASED ON THE 2021 INTERNATIONAL ENERGY CONSERVATION CODE. 2 ALL SUPPLY, RETURN AND EXHAUST DUCTWORK SHALL BE SEALED AIRTIGHT WITH DUCT SEALANT ALONG ALL SEAMS AND JOINTS. 3 SEE HVAC INSULATION SCHEDULE ON SHEET M8.1 FOR DUCT INSULATION REQUIREMENTS. GENERAL MECHANICAL NOTES 1 THE MECHANICAL DESIGN IS BASED ON THE 2021 INTERNATIONAL MECHANICAL CODE. MECHANICAL WORK SHALL COMPLY WITH ALL APPLICABLE CODES AND LOCAL CODE AMENDMENTS. VERIFY ALL REQUIREMENTS PRIOR TO SUBMITTING BID OR COMMENCING WORK. 2 ALL DUCTWORK SHALL BE CONSTRUCTED OF GALVANIZED SHEET METAL ‐ CONSTRUCTION AND INSTALLATION SHALL CONFORM TO THE CURRENT EDITION OF SMACNA OR AS REQUIRED BY ALL APPLICABLE CODES. 3 CONSTRUCT ALL SUPPLY AND RETURN DUCTWORK TO SMACNA 2" PRESSURE CLASS. 4 DIMENSIONS OF DUCTWORK SHOWN INDICATES CLEAR INSIDE DIMENSIONS ‐ WHERE DUCT LINER IS TO BE ADDED, INCREASE THE SIZE OF SHEET METAL ACCORDINGLY. 5 UNLESS NOTED OTHERWISE, THE SIZE OF THE BRANCH DUCT SERVING A SINGLE DIFFUSER SHALL BE THE SAME AS THE NECK SIZE OF THE DIFFUSER SERVED. 6 WALL MOUNTED THERMOSTATS AND SENSORS SHALL BE INSTALLED 48" ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE. THERMOSTATS AND SENSORS LOCATED ON EXTERIOR WALL SURFACES SHALL BE PROVIDED WITH AN INSULATED SUB‐BASE. 7 THERMOSTATS FOR COOLING AND HEATING EQUIPMENT SHALL BE 7‐DAY PROGRAMMABLE TYPE, 4 PERIODS PER DAY, 10‐HOUR BATTERY BACK‐UP, 2‐HOUR OVERRIDE, 5 DEG DEAD‐BAND, HEAT/COOL/OFF/AUTO CHANGEOVER, AUTO SETBACK TO 55 DEG F (HEAT) AND 85 DEG F (COOL), LCD BACKLIT DISPLAY, HARD WIRED POWER, HARD WIRED CONTROL. 8 TEMPORARY HEATING:  THE PERMANENT HVAC SYSTEM MAY NOT BE UTILIZED FOR HEATING UNTIL ALL GYPSUM WORK IS COMPLETED AND HAS BEEN PAINTED.  IF THE PERMANENT HVAC SYSTEM IS UTILIZED DURING CONSTRUCTION, ALL DUCT INTAKES SHALL BE COVERED WITH FILTER MEDIA (MERV‐8 RATING).  IF EXCESSIVE DUST OR DEBRIS HAS ENTERED THE SYSTEM THEN ALL COIL AND DUCT SURFACES SHALL BE CLEANED.  NEW FILTERS ARE TO BE PROVIDED JUST PRIOR TO TURNOVER TO OWNER. TEMPORARY HEATING OF THE BUILDING PRIOR TO ANY USE OF THE PERMANENT HVAC SYSTEM SHALL BE THE RESPONSIBILITY OF THE G.C. 9 TEMPERATURE CONTROLS SHALL BE DESIGN BUILD, CUSTOM, FIELD FABRICATED TO MATCH CORRESPONDING EQUIPMENT. THE SYSTEM SHALL UTILIZE STAND ALONE ELECTRONIC COMPONENTS. THE CONTRACTOR SHALL PROPERLY SELECT, PROVIDE AND INSTALL SYSTEM(S) INCLUDING ALL COMPONENTS NECESSARY FOR A FULL AND COMPLETE, OPERATIONAL SYSTEM. THIS INCLUDES, BUT IS NOT LIMITED TO: LOW VOLTAGE WIRING, THERMOSTATS, DAMPER MOTORS, SOLENOIDS, RELAYS, CONTACTORS, STARTERS, TIME CLOCKS, CONTROL PANELS, SYSTEM COMMISSIONING AND OWNER TRAINING. ALL LINE VOLTAGE INTERFACING SHALL BE COORDINATED DIRECTLY WITH THE ELECTRICAL CONTRACTOR. PROVIDE SUBMITTALS ON COMPONENTS AND WIRING DIAGRAMS PRIOR TO ORDERING 10 HANGING, ANCHORING AND SUPPORT OF EQUIPMENT, DUCTS, PIPING AND ACCESSORIES IS DESIGN BUILD BY THE MC. THE SUPPORTS SHALL MEET CODE. 11 ALWAYS INSTALL EQUIPMENT PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. GENERAL PLUMBING NOTES 1 THE PLUMBING DESIGN IS BASED ON THE 2021 INTERNATIONAL PLUMBING CODE. PLUMBING WORK SHALL COMPLY WITH ALL APPLICABLE CODES AND LOCAL CODE AMENDMENTS. VERIFY ALL REQUIREMENTS PRIOR TO SUBMITTING BID OR COMMENCING WORK. 2 POTABLE WATER PIPING 2" AND SMALLER SHALL BE PEX‐A TUBING MANUFACTURED BY UPONOR/WIRSBO OR APPROVED EQUAL. FITTINGS SHALL BE EXPANSION TYPE WITH SECONDARY EXPANSION RING (NOT CRIMPED). CW SHALL BE RUN IN BLUE PIPE, HW & HWC IN RED, OTHER SYSTEMS CLEAR. PIPING SHALL BE PROPERLY SUPPORTED USING PLENUM RATED GALVANIZED TROUGHS OR CHANNELS HUNG AT MAXIMUM 8' INTERVALS. UNSUPPORTED PEX MAY NOT EXCEED 32". 3 PUSH‐TO‐CONNECT PLUMBING FITTINGS (I.E. SHARKBITE OR SIMILAR) AND PULLED TEE FITTINGS WILL NOT BE ACCEPTED. 4 POTABLE WATER VALVES SHALL BE FULL PORT, BALL TYPE. 5 INSTALL FULL SIZE CONDENSATE AND TRAP FOR ALL COOLING COILS.  DISCHARGE FULL SIZE DRAIN TO MOP SINK OR LAVATORY P‐TRAP TAILPIECE AND TO ROOF FOR ROOFTOP UNITS. 6 HANGING, ANCHORING AND SUPPORT OF EQUIPMENT, PIPING AND ACCESSORIES IS DESIGN BUILD BY THE PC. THE SUPPORTS SHALL MEET CODE. 7 ALWAYS INSTALL EQUIPMENT PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. 8 PRIOR TO BUILDING TURNOVER, THE POTABLE WATER SYSTEM SHALL BE CLEANED AND DISINFECTED PER IPC SECTION 610. THE SYSTEM SHALL BE FLUSHED, CHLORINATED AND PURGED. REPEAT UNTIL THE SYSTEM HAS BEEN PROVEN TO PASS BACTERIAL EXAMINATION. A REPORT SHALL BE SUBMITTED TO THE AUTHORITY HAVING JURISDICTION. PLUMBING ENERGY CODE INSULATION NOTES AND 1 THE PLUMBING DESIGN IS BASED ON THE 2021 INTERNATIONAL ENERGY CONSERVATION CODE. 2 COMMERCIAL POTABLE COLD WATER PIPING SHALL BE INSULATED USING FIBERGLASS INSULATION WITH ALL SERVICE JACKET HAVING MAXIMUM 'K' FACTOR OF 0.27.  INSULATION THICKNESS SHALL BE 0.5". DO NOT REMOVE THIS ITEM FROM THE PROJECT AS IT IS REQUIRED FOR CONDENSATE CONTROL. 15 DEC 2022 PERMIT SET 2023-03-29  )  ( ' & $ % (E)GUH (E)GUH (E)GUH (E)GUH (E)GUH(E)GUH (E)GUH (E)GUH (E)EF‐1 (E)EF‐1 (E)LVR‐2 (E)LVR‐1(E)CF (E)CF (E)CF(E)CF 1 WAREHOUSE ‐ EVAP‐1 EVAP‐2 ~ NOT IN SCOPE CW 0.75" 0.75" 0.75" 2 2 3 3 HOA‐1 HOA‐2 4 4 5 5 T EVAP‐1 T EVAP‐2 42"x42" 42"x42" ' [  ' [  ' [  ' [  ' [  ' [  ' [  ' [  ' [  ' [  CW CW 0.75" CW CON TINUES  AROUND WAREHOUSE ‐ INSTALLED AS PART  OF PHASE 1 6 7 7 8 8 8 9 9 THIS AREA IS N OT IN SCOPE OF WORK. ROUTE 0.5" CW TO EVAP SECTION AN D CON N ECT 0.5" C APPED  CW TO EVAP‐1/EVAP‐2. PIPE SHALL BE SLOPED AT 2% PITCH  TOWARDS SOLENOID FOR PROPPER DRAINAGE. INSTALL  SOLENOID VALVE AS SHOWN, IN DRAIN MODE THE PIPE SHALL  DISCHARG E EXTERNALLY TO GRADE. EXISTING EXHAUST FANS SHALL BE REMOVED. ROUTE N EW  42"x42" DUCT FROM EVAP COOLERS THROUGH PENETRATION.  INFILL AN Y OPEN SPACE THROUGH PEN ETRATION AND SEAL  AIRTIGHT. HOA STARTER SUPPLIED BY MC AN D WIRED BY EC. STARTER  SHALL BE RATED FOR EVAP HP LISTED IN  SCHEDULES WITH  1 20 V I/O FOR LOUVER CONTROL AN D 24V INPUT FROM  T'STAT. EC SHALL HAVE 120 V CONTROL TO OPEN  (E)LVR‐1 /2  DAMPERS WHEN EVAP‐1/2 IS OPERATING. (E)LVR‐1/2 OPERATION SHALL BE CONTROLLED BY HOA  STARTERS. PROVIDE 120 V MO TORIZED DAMPER AT DISCHARGE  DUCTWORK. D AMPER TO BE IN TERLOCKED THROUGH EVAP  COOLER TO OPEN  ONLY DURING EVAP COOLER OPERATION.  COORDINATE WITH EC TO PROVIDE ELECTRICAL INTERLOCK  AND CONTROL. EVAP DISCHARGE DUCTWORK FROM TOP OF UNIT ROUTED  EXPOSED OUTSIDE. EXTERIOR DUCTWORK SHALL BE INSULATED  AND WRAPPED PER SHEET M8.1. PROVIDE SECONDARY OUTER  DUCTWORK CON STRUCTED OF ALUMINUM AROUN D INSULATION  FOR WEATHER PROTECTION. PC SHALL PROVIDE FILL AND DRAIN KIT PER FILL AND DRAIN  KIT SEQUEN CE ON THIS SHEET. ALL CW PIPING EXTERIOR OF BUILDING EN VELOPE SHALL BE  SLOPED AT MINIMUM 2% TOWARDS DRAIN SOLENOID. THIS  SHALL INCLUDE PIPIN G FROM EVAP COOLER TO DRAIN  SOLENOID. FLAG NOTES: 1 2 3 4 5 6 7 8 9 PC SHALL PROVIDE, INSTALL, AND CONTROL A FUNCTIONING FILL  AND D RAIN KIT FOR EXTERIOR GRADE MOUNTED EVAP COOLERS.  FACTORY PROVIDED KITS, MEETING THE NEED S OF THIS  SEQUENCE AN D INSTALLATION, ARE ACCEPTABLE.  FOR  OUTSIDE AIR TEMPERATURES GREATER THAN 60°F,  INDOOR  SO LENOID VALVE SHALL REMAIN OPEN, AND OUTDOOR  DRAINAG E SOLENOID SHALL CLOSE.  FOR  OUTSIDE AIR TEMPERATURES LESS THAN 50°F, INDOOR  SOLENOID SHALL CLOSE, AND OUTDOOR DR AINAGE SOLENOID  SHALL O PEN.  P ROVIDE AMBIENT OUTDOOR AIR  TEMPERATURE SENSOR,  WIRING, RELAYS, AND INTERLOCKS AS R EQUIRED. PC TO  CO ORDIN ATE 120 V SUPPLY POWER AS NECESSARY. ALL LINE  VOLTAGE WIRING BY EC, LOW VOLTAGE WIRING BY PC. FILL AND DRAIN KIT 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 = 1'‐0"PHASE 2 FIRST FLOOR MECHANICAL PLAN 15 DEC 2022 PERMIT SET 2023-03-29 &DQ\RQ$YH6XLWH)RUW&ROOLQV&2_ (DVW/LQFROQZD\&KH\HQQH:<_ ZZZ9)/$FRP '5$:,1*180%(5 352-(&7180%(5 6($/ ,1$662&,$7,21:,7+ 6WUHQJWKLQGHVLJQ6WUHQJWKLQSDUWQHUVKLS 6WUHQJWKLQFRPPXQLW\ 9$8*+7)5<(/$5621$521621$5&+,7(&785(,17(5,256,1& 7+,6'5$:,1*0$<127%(3+272*5$3+('6&$11('75$&('25 &23,(',1$1<0$11(5:,7+2877+(:5,77(13(50,66,212)9)/$ &23<5,*+7 6+((7,668$1&(6 '(6&5,37,21 '$7( A R C H I T E C T U R E + I N T E R I O R S &,9,/(1*,1((5 /$1'6&$3($5&+,7(&7 6758&785$/(1*,1((5 0(&+$1,&$/(1*,1((5 3/80%,1*(1*,1((5 (/(&75,&$/(1*,1((5                   $ 0 $0 0 0(&+$1,&$/ 6&+('8/(6 '(1526( 180(5,&$ '(1526(&2857 )257&2//,16&2 3(50,76(7  3(50,76(7  EVAP‐1, EVA P‐2 HVAC INSULATION SCHEDULE INSULATION KEY INSULATION DESCRIPTION TYPE THICKNESS (IN) DENSITY (PCF) TOTAL R VALUE ACCOUSTICAL (NRC) H01 RECTANGULAR DUCT IN CEILING SPACE WITH NO ROOF LINER 1.0 1.5 4.2 0.70 H02 RECTANGULAR DUCT IN CEILING SPACE ADJACENT TO EXTERIOR ROOF LINER 1.5 1.5 6.0 0.80 H03 RECTANGULAR DUCT IN CEILING SPACE ADJACENT TO EXTERIOR ROOF AND SPACE IS A RETURN PLENUM LINER 1.0 1.5 4.2 0.70 H04 FLEXIBLE DUCT TO DIFFUSER FLEX 1.5 ~6.0 ~ H05 ROUND DUCT IN CEILING SPACE WITH NO ROOF WRAP 1.5 0.75 4.2 ~ H06 ROUND DUCT IN SPACE ADJACENT TO EXTERIOR ROOF WRAP 2.1 0.75 6.0 ~ H07 RECTANGULAR DUCT EXTERIOR TO BUILDING ENVELOPE. DOUBLE WALL WATER TIGHT CONSTRUCTION. WRAP NOT ACCEPTABLE LINER 3.0 1.5 12 0.95 H08 ROUND DUCT EXPOSED IN CONDITIONED SPACE N/R ~~~ H09 RECTANGULAR DUCT EXPOSED IN CONDITIONED SPACE LINER 1.0 1.5 4.2 0.70 H10 ROUND OR RECTANGULAR OUTSIDE AIR DUCT WRAP 5.0 0.75 12 ~ H11 ROUND DUCT IN VENTILATED CRAWL SPACE WRAP 5.0 0.75 12 ~ H12 RECTANGULAR DUCT IN VENTILATED CRAWL SPACE LINER 3.0 1.5 12 0.95 H13 BURIED ROUND DUCT INTERNAL ~6.0 ~ NOTES:  MC SHALL PROVIDE WITH HOA STARTER FOR EACH EVAP COOLER RATED FOR SCHEDULED HP, AS INDICATED ON  PLAN S,  WIRED BY EC. HOA SHALL CON TROL (E)LVR OPERATION VIA 120V WIRING AND (E)LVR DAMPER SHALL OPEN WHILE EVAP  COOLER IS OPERATING. EVAP‐1 SHALL BE SET TO OPERATE AT 78°F AND EVAP‐2 SHALL BE SET TO OPERATE AT 80°F.  GRILLES, REGISTERS AND DIFFUSERS SCHEDULE TAG MAKE & MODEL NUMBER DESCRIPTION NECK SIZE DUTY COLOR FRAME SIZE FRAME TYPE FRAME CONST DAMPER REMARKS D‐4 TITUS 300RL‐1 SIDEWALL SUPPLY DIFFUSER 30"x24"SUPPLY WHITE NECK +2 SIDEWALL STEEL YES 15 DEC 2022 PERMIT SET 2023-03-29 FEEDER SCHEDULE - EXISTING 419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191 108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710 www.VFLA.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. COPYRIGHT: SHEET ISSUANCES DESCRIPTION DATE A R C H I T E C T U R E + I N T E R I O R S ELECTRICAL ENGINEER: 4450 DENROSE NUMERICA 4450 DENROSE COURT FORT COLLINS, CO 21096 12/21/22 37 1 2 7 C u l l i s o n R i d g e R o a d Se v e r a n c e , C O 8 0 5 5 0 Ph : 9 7 0 . 6 8 6 . 1 0 0 4 Em a i l : l a r r y @ e l e c t r i c o n - e n g . c o m El e c t r i c o n El e c t r i c a l E n g i n e e r i n g PERMIT SET 12/21/22 E1.1 SWITCHESLEGEND OUTLETS DESIGNATIONS SOUND and SIGNALCIRCUITRY and RACEWAYS CONTROL SWITCHES PHASE 2 NOTES, SCHEDULES & ONE-LINE DIAGRAM PERMIT SET 2023-03-29 GENERAL POWER NOTES: 5.1 F 151.122.143 E D C A B VESTIBULE RECEPTION OFFICE OPEN OFFICE SOUTH OFFICESMALL CONF. OFFICE OFFICE OPEN OFFICE WEST SMALL CONF. LARGE CONF. HALL SMALL CONF. WORK ROOM OFFICE OPEN OFFICE EAST BREAKBREAK JAN. WOMEN'S FIRE RISER ROOM MEN'S HOTEL SPACE OFFICE WAITING 419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191 108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710 www.VFLA.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. COPYRIGHT: SHEET ISSUANCES DESCRIPTION DATE A R C H I T E C T U R E + I N T E R I O R S ELECTRICAL ENGINEER: 4450 DENROSE NUMERICA 4450 DENROSE COURT FORT COLLINS, CO 21096 12/21/22 37 1 2 7 C u l l i s o n R i d g e R o a d Se v e r a n c e , C O 8 0 5 5 0 Ph : 9 7 0 . 6 8 6 . 1 0 0 4 Em a i l : l a r r y @ e l e c t r i c o n - e n g . c o m El e c t r i c o n El e c t r i c a l E n g i n e e r i n g PERMIT SET 12/21/22 E2.1 PHASE 2 HVAC POWER PLAN PERMIT SET 2023-03-29