HomeMy WebLinkAboutPOWERHOUSE 2 - PDP220006 - SUBMITTAL DOCUMENTS - ROUND 2 - STORMWATER-RELATED DOCUMENTSFigure C1. Proposed 100-Year Floodplain from 2D Model (flood depth less than 0.1 ft not shown). APPROX SCALE: 1” = 240’ DRY ZONE ALONG DRIVEWAY (APPROX 160’ L x 60‘ W) MAX 100-YR DEPTH AT GUTTER FLOW LINE = 15 IN MAX 100-YR DEPTH AT ALONG DRIVEWAY = 2.0 FT PROPOSED POWERHOUSE BLDG N COLLEGE AVE E VINE DR JEROME ST E SUNIGA DR 2D 100 YR Floodplain Scale N NORTH ACCESS ROUTE SOUTH ACCESS ROUTE MAX 100-YR DEPTH AT SOUTH ACCESS ROUTE = 1.1 FT 100-YEAR Figure C2. Proposed 100-Year Floodplain from 2D Model (flood depth less than 0.5 ft not shown). APPROX SCALE: 1” = 240’ DRY ZONE ALONG DRIVEWAY (APPROX 160’ L x 60‘ W) MAX 100-YR DEPTH AT DRIVEWAY = 2.0 FT PROPOSED POWERHOUSE BLDG N COLLEGE AVE E VINE DR JEROME ST E SUNIGA DR 2D 100 YR Floodplain Scale N MAX 100-YR DEPTH AT GUTTER FLOW LINE = 15 IN NORTH ACCESS ROUTE SOUTH ACCESS ROUTE MAX 100-YR DEPTH AT SOUTH ACCESS ROUTE = 1.1 FT 100-YEAR Figure C3. Close-Up of Proposed 100-Year Floodplain from 2D Model (flood depth less than 0.1 ft not shown). APPROX SCALE: 1” = 150’ DRY ZONE ALONG DRIVEWAY (APPROX 160’ L x 60‘ W) MAX 100-YR DEPTH ALONG DRIVEWAY = 2.0 FT PROPOSED POWERHOUSE BLDG N COLLEGE AVE E VINE DR JEROME ST 2D 100 YR Floodplain Scale N MAX 100-YR DEPTH AT GUTTER FLOW LINE = 15 IN NORTH ACCESS ROUTE SOUTH ACCESS ROUTE MAX 100-YR DEPTH AT SOUTH ACCESS ROUTE = 1.1 FT 100-YEAR Figure C4. Proposed 50-Year Floodplain from 2D Model (flood depth less than 0.1 ft not shown). APPROX SCALE: 1” = 240’ N COLLEGE AVE E VINE DR JEROME ST E SUNIGA DR PROPOSED POWERHOUSE BLDG DRY ZONE ALONG DRIVEWAY (APPROX 210’ L x 60‘ W) MAX 50-YR DEPTH AT GUTTER FLOW LINE = 10 IN MAX 50-YR DEPTH ALONG DRIVEWAY = 1.7 FT 2D 50 YR Floodplain Scale N NORTH ACCESS ROUTE SOUTH ACCESS ROUTE MAX 50-YR DEPTH AT SOUTH ACCESS ROUTE = 0.9 FT 50-YEAR Figure C5. Proposed 50-Year Floodplain from 2D Model (flood depth less than 0.5 ft not shown). APPROX SCALE: 1” = 240’ N COLLEGE AVE E VINE DR JEROME ST E SUNIGA DR PROPOSED POWERHOUSE BLDG MAX 50-YR DEPTH ALONG DRIVEWAY = 1.7 FT 2D 50 YR Floodplain Scale N MAX 50-YR DEPTH AT GUTTER FLOW LINE = 1 FT DRY ZONE ALONG DRIVEWAY (APPROX 210’ L x 60‘ W) NORTH ACCESS ROUTE SOUTH ACCESS ROUTE MAX 50-YR DEPTH AT SOUTH ACCESS ROUTE = 0.9 FT 50-YEAR Figure C6. Close-Up of Proposed 50-Year Floodplain from 2D Model (flood depth less than 0.1 ft not shown). APPROX SCALE: 1” = 150’ N COLLEGE AVE E VINE DR JEROME ST PROPOSED POWERHOUSE BLDG DRY ZONE ALONG DRIVEWAY (APPROX 210’ L x 60‘ W) MAX 50-YR DEPTH ALONG DRIVEWAY = 1.7 FT 2D 50 YR Floodplain Scale N MAX 50-YR DEPTH AT GUTTER FLOW LINE = 1 FT NORTH ACCESS ROUTE SOUTH ACCESS ROUTE MAX 50-YR DEPTH AT SOUTH ACCESS ROUTE = 0.9 FT 50-YEAR