Loading...
HomeMy WebLinkAbout630 YARROW CIR - DISCLOSURES - 12/23/2019Testing Company: Name: Scott Home Inspection LLC Address: Phone: 970-532-2424 www.scotthomeinspection.com Technician: Name: Luke Griess Credentials: RESNET Certified HERS Rater #2186412 Email: luke@scotthomeinspection.com Building Information: Project ID: 630 Yarrow Cir Address: 630 Yarrow Cir Fort Collins , CO 80524 Geo-Tag Data: Latitude: 40.601285 Longitude: -105.065488 Timestamp: 2019-12-17 12:39:09 Customer Information: Name: Mighty Hand Construction Address: Phone: 720-206-8719 Email: micah@mightyhandconstruction.com Measured Leakage: 801.8 CFM50 Test ID: Final 3 Purpose of Test: RESNET Multi-Pt Env. Leakage Measured ACH50: 2.98 (+/- 1.9%) Effective Leakage Area: 42.2 in² Building Volume: 16,170.0 ft³ Enclosure Surface Area: 0.0 ft² Flow Coefficient (C): 59.0 (+/- 7.2%) Exponent (n): 0.667 (+/- 0.021) Correlation Coefficient: 0.99985 Test Standard: RESNET 380 Multi-Point Test Mode: Depressurize Test Characteristics: Indoor Temp: 68 °F Altitude: 4,906.0 ft Outdoor Temp: 35 °F Time Average Period: 10 seconds Test Date and Time: 2019-12-23 09:06:23 Envelope Leakage Test Test Readings: Target (Pa) Bldg (Pa) Adj Bldg (Pa) Fan (Pa) Flow (cfm) Config Baseline -0.9 -60.0 -60.3 -59.4 -25.2 916.0 Ring A -48.0 -48.4 -47.5 -183.1 801.9 Ring B -35.0 -35.7 -34.8 -121.0 653.0 Ring B -23.0 -24.0 -23.1 -70.1 498.1 Ring B -10.0 -9.4 -8.5 -122.6 252.1 Ring C Test Equipment: Flow Device: Model 3 110V Fan Pressure Gauge: DG700 Serial #: 12525 Calibration Date: 2017-05-11 Deviations from Standard: None Comments: Envelope Leakage Test (Page 2) Report generated by TEC Auto Test version 1.6.1 (0), © 2019 by The Energy Conservatory, Inc. Testing Company: Name: Scott Home Inspection LLC Address: Phone: 970-532-2424 www.scotthomeinspection.com Technician: Name: Luke Griess Credentials: RESNET Certified HERS Rater #2186412 Email: luke@scotthomeinspection.com Building Information: Project ID: 630 Yarrow Cir Address: 630 Yarrow Cir Fort Collins , CO 80524 Geo-Tag Data: Latitude: 40.601285 Longitude: -105.065488 Timestamp: 2019-12-17 12:39:09 Customer Information: Name: Mighty Hand Construction Address: Phone: 720-206-8719 Email: micah@mightyhandconstruction.com Measured Leakage: 801.8 CFM50 Test ID: Final 3 Purpose of Test: RESNET Multi-Pt Env. Leakage Measured ACH50: 2.98 (+/- 1.9%) Effective Leakage Area: 42.2 in² Building Volume: 16,170.0 ft³ Enclosure Surface Area: 0.0 ft² Flow Coefficient (C): 59.0 (+/- 7.2%) Exponent (n): 0.667 (+/- 0.021) Correlation Coefficient: 0.99985 Test Standard: RESNET 380 Multi-Point Test Mode: Depressurize Test Characteristics: Indoor Temp: 68 °F Altitude: 4,906.0 ft Outdoor Temp: 35 °F Time Average Period: 10 seconds Test Date and Time: 2019-12-23 09:06:23 Envelope Leakage Test Test Readings: Target (Pa) Bldg (Pa) Adj Bldg (Pa) Fan (Pa) Flow (cfm) Config Baseline -0.9 -60.0 -60.3 -59.4 -25.2 916.0 Ring A -48.0 -48.4 -47.5 -183.1 801.9 Ring B -35.0 -35.7 -34.8 -121.0 653.0 Ring B -23.0 -24.0 -23.1 -70.1 498.1 Ring B -10.0 -9.4 -8.5 -122.6 252.1 Ring C Test Equipment: Flow Device: Model 3 110V Fan Pressure Gauge: DG700 Serial #: 12525 Calibration Date: 2017-05-11 Deviations from Standard: None Comments: Envelope Leakage Test (Page 2) Report generated by TEC Auto Test version 1.6.1 (0), © 2019 by The Energy Conservatory, Inc.