HomeMy WebLinkAbout4432 FOX GROVE DR - DISCLOSURES - 5/20/2019BUILDING LEAKAGE TEST Date of Test: 5/20/2019 Test File: 4432 Fox Grove Dr LC Home tec Technician: Neal Girard - EnergyLogic Project Number: Customer: LC Home Phone: Fax: Building Address: 4432 Fox Grove Dr Test Results at 50 Pascals: cfm50 Airflow 952 (+/- 1.8 %) ACH50 1.75 Leakage Areas: 96.9 in² (+/- 14.4 %) Canadian EqLA @ 10 Pa 51.2 in² (+/- 22.8 %) LBL ELA @ 4 Pa Building Leakage Curve: Flow Coefficient (C) = 72.5 (+/- 35.6 %) Exponent (n) = 0.658 (+/- 0.092) Correlation Coefficient = 0.99492 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) 100 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 5/20/2019 Test File: 4432 Fox Grove Dr LC Home tec Building Information Volume (ft³) 32679 Surface Area: (ft²) Floor Area: (ft²) Height (ft) 20 Year of Construction 2019 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 5/20/2019 Test File: 4432 Fox Grove Dr LC Home tec Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 65.0 40.0 Post-Test 65.0 40.0 Average 65.0 40.0 5000.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration 0.0 n/a n/a -60.0 -60.0 37.4 1112 1092 1.8 Ring A -55.0 -55.0 32.0 1030 1012 -0.1 Ring A -50.0 -50.0 27.1 950 933 -1.9 Ring A -45.0 -45.0 230.6 899 883 -0.5 Ring B -40.0 -40.0 197.7 833 818 -0.4 Ring B -35.0 -35.0 171.3 776 762 1.3 Ring B 0.0 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 5/20/2019 Test File: 4432 Fox Grove Dr LC Home tec Comments Garage - 45 Pa Mech - 50 Pa BUILDING LEAKAGE TEST Date of Test: 5/20/2019 Test File: 4432 Huntsman Dr LC Home tec Technician: Neal Girard - EnergyLogic Project Number: Customer: LC Home Phone: Fax: Building Address: 4432 Huntsman Dr Test Results at 50 Pascals: cfm50 Airflow 823 (+/- 4.1 %) ACH50 1.98 Leakage Areas: 68.4 in² (+/- 44.0 %) Canadian EqLA @ 10 Pa 32.2 in² (+/- 69.6 %) LBL ELA @ 4 Pa Building Leakage Curve: Flow Coefficient (C) = 38.3 (+/- 108.5 %) Exponent (n) = 0.784 (+/- 0.281) Correlation Coefficient = 0.98156 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) 100 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 5/20/2019 Test File: 4432 Huntsman Dr LC Home tec Building Information Volume (ft³) 24925 Surface Area: (ft²) Floor Area: (ft²) Height (ft) 20 Year of Construction 2019 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 36002 11/15/2012 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 5/20/2019 Test File: 4432 Huntsman Dr LC Home tec Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 68.0 40.0 Post-Test 68.0 40.0 Average 68.0 40.0 5000.0 Data Points - Automated Test (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -4.0 n/a n/a -64.1 -58.8 26.3 936 921 -1.4 Ring A -55.7 -50.5 217.7 874 860 3.8 Ring B -54.1 -48.9 183.3 802 790 -2.2 Ring B -49.1 -43.8 163.7 759 747 0.8 Ring B -44.1 -38.8 130.8 679 668 -1.0 Ring B -6.6 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Correlation coefficient (0.982) outside of acceptable limits. - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 5/20/2019 Test File: 4432 Huntsman Dr LC Home tec Comments Garage - 45 Pa Mech - 50 Pa