HomeMy WebLinkAbout6008 SPINDLEBUSH LN - DISCLOSURES - 5/5/2017BUILDING LEAKAGE TEST Date of Test: 5/5/2017 Technician: Jay Bundy Test File: 6008 Spindlebush Customer: Toll Brothers 10 Inverness E Dr Ste 125 Englewood, CO 80112 Phone 303-708-0730 Building Address: 6008 Spindlebush Fort Collins, Colorado 80528 Test Results 1. Airflow at 50 Pascals: 1420 CFM ( +/- 0.2 %) (50 Pa = 0.2 w.c.) 2.21 ACH 0.41 CFM per ft2 floor area 2. Leakage Areas: 130.0 in2 ( +/- 1.8 %) Canadian EqLA @ 10 Pa 64.6 in2 ( +/- 2.8 %) LBL ELA @ 4 Pa 3. Minneapolis Leakage Ratio: 0.16 CFM50 per ft2 surface area 4. Building Leakage Curve: Flow Coefficient (C) = 83.4 ( +/- 4.4 %) Exponent (n) = 0.725 ( +/- 0.011 ) Correlation Coefficient = 0.99939 5. Test Settings: Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 72.9 CFM 0.11 ACH 2. Estimated Design Infiltration Rate: Winter: 81.7 CFM 0.13 ACH Summer: 48.7 CFM 0.08 ACH 3. Recommended Whole Building Mechanical 62.4 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 5/5/2017 Test File: 6008 Spindlebush Building Conditions Inside Temperature: 64 deg F Heating Fuel: Gas Outside Temperature: 58 deg F Heating Fuel Cost: # of Stories 1.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 3.0 Volume: 38565 ft3 Ventilation Weather Factor: 0.87 Surface Area: 8884 ft2 Energy Climate Factor: 17.0 Floor Area: 3440 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments Garage with Respect to House= 48.9 PA BUILDING LEAKAGE TEST Page 3 Date of Test: 5/5/2017 Test File: 6008 Spindlebush Data Points: Data Entered Manually Nominal Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow Temperature Adjusted Flow % Error Fan Configuration Baseline Std Dev (Pa) -3.3 n/a +/- 0.00 -65.0 84.6 1655 1645 0.1 Ring A -60.0 74.6 1556 1547 0.1 Ring A -55.0 64.5 1450 1442 -0.2 Ring A -50.0 55.7 1350 1342 0.1 Ring A -45.0 47.2 1245 1238 0.3 Ring A -40.0 37.6 1115 1109 -1.3 Ring A -35.0 31.7 1025 1019 1.0 Ring A -4.3 n/a +/- 0.00