HomeMy WebLinkAbout2263 SHANDY ST - DISCLOSURES - 5/22/2017 (6)BUILDING LEAKAGE TEST GS Services, LTD 2000 S. College Ave. #308 Fort Collins, CO 80525 Date of Test: 5/22/2017 Test File: Hartford Homes - 2263 Shandy St - BDma Technician: Project Number: Customer: Hartford Homes Building Address: 2263 ShandynSt Fort Collins, CO Test Results 1. Airflow at 50 Pascals: 933 CFM50 ( +/- 0.8 %) (50 Pa = 0.2 w.c.) 2.99 ACH50 2. Leakage Area: 51.3 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 28.9 ( +/- 6.4 %) Exponent (n) = 0.888 ( +/- 0.018 ) Correlation Coefficient = 0.99975 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 5/22/2017 Test File: Hartford Homes - 2263 Shandy St - BDma Building Information Volume 18710 Surface Area Floor Area 1665 Height # of Bedrooms # of Occupants Year of Construction Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 19247 Default Micromanometer Energy Conservatory DG700 19028-7 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 5/22/2017 Test File: Hartford Homes - 2263 Shandy St - BDma Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 64.0 44.0 5000.0 Data Points - Data Entered Manually Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -0.3 n/a n/a -59.8 -59.4 35.2 1079 1084 -0.3 Ring A -54.5 -54.1 30.0 998 1002 0.2 Ring A -50.0 -49.6 238.9 915 919 -0.8 Ring B -44.8 -44.4 199.1 836 840 0.0 Ring B -39.6 -39.2 160.8 752 755 0.5 Ring B -35.1 -34.7 127.8 671 674 -0.1 Ring B -30.0 -29.6 98.2 589 592 1.0 Ring B -25.3 -24.9 71.7 504 506 0.8 Ring B -20.1 -19.7 45.2 401 403 -1.3 Ring B -0.5 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 5/22/2017 Test File: Hartford Homes - 2263 Shandy St - BDma Comments House WRT Garage = -46.8 Pa