Loading...
HomeMy WebLinkAbout2220 MACKINAC ST - DISCLOSURES - 5/25/2017BUILDING LEAKAGE TEST GS Services, LTD. 2000 S College Ave #308 Fort Collins, CO 80525 Email: buildingperformance@gsservices.com Website: gsservices.com Date of Test: 5/25/2017 Test File: Hartford Homes - 2220 Mackinac St - BD1 Technician: Project Number: Customer: Hartford Homes Building Address: 2220 Mackinac St Fort Collins, CO Test Results 1. Airflow at 50 Pascals: 1129 CFM50 ( +/- 1.9 %) (50 Pa = 0.2 w.c.) 2.66 ACH50 2. Leakage Area: 62.1 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 44.2 ( +/- 13.2 %) Exponent (n) = 0.828 ( +/- 0.037 ) Correlation Coefficient = 0.99901 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 5/25/2017 Test File: Hartford Homes - 2220 Mackinac St - BD1 Building Information Volume 25485 Surface Area Floor Area 2225 Height # of Bedrooms # of Occupants Year of Construction 2017 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 19247 Default Micromanometer Energy Conservatory DG700 19028-7 9/9/2014 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 5/25/2017 Test File: Hartford Homes - 2220 Mackinac St - BD1 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 68.0 59.0 5000.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -1.8 n/a n/a -61.7 -58.8 45.1 1218 1263 -2.2 Ring A -55.4 -52.5 38.1 1121 1163 -1.2 Ring A -49.6 -46.6 32.9 1044 1083 1.6 Ring A -44.3 -41.3 27.4 955 990 2.6 Ring A -38.0 -35.1 189.1 815 845 0.3 Ring B -32.4 -29.5 140.7 704 730 0.1 Ring B -25.2 -22.3 87.6 557 577 -0.1 Ring B -20.9 -17.9 59.9 461 478 -1.0 Ring B -4.0 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 5/25/2017 Test File: Hartford Homes - 2220 Mackinac St - BD1 Comments House WRT Garage = -46.4 Pa