HomeMy WebLinkAbout2263 ADOBE DR - DISCLOSURES - 3/1/2017 (4)BUILDING LEAKAGE TEST Date of Test: 3/1/2017 Test File: 2263 Adobe Dr LC Home Multi Point Tectite Technician: Neal Girard - EnergyLogic, Inc. Project Number: 44654 Customer: LC Home Building Address: 2263 Adobe Dr Ft. Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 729 CFM50 ( +/- 1.8 %) (50 Pa = 0.2 w.c.) 2.01 ACH50 2. Leakage Area: 40.1 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 31.7 ( +/- 26.3 %) Exponent (n) = 0.802 ( +/- 0.070 ) Correlation Coefficient = 0.99620 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 45.5 CFM 0.13 ACH 9.1 CFM per person 2. Estimated Design Infiltration Rate: Winter: 79.9 CFM 0.22 ACH Summer: 50.2 CFM 0.14 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 60.0 CFM Base Rate: 60.0 CFM BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 3/1/2017 Test File: 2263 Adobe Dr LC Home Multi Point Tectite Building Information Volume 21761 Surface Area Floor Area 2246 Height 25 # of Bedrooms 4 # of Occupants 5 Year of Construction 2017 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 6108-5 1/17/2014 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 3/1/2017 Test File: 2263 Adobe Dr LC Home Multi Point Tectite Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 71.0 41.0 5000.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -2.7 n/a n/a -62.0 -57.4 185.3 807 794 -2.4 Ring B -57.5 -52.9 173.3 780 769 0.8 Ring B -54.6 -50.0 156.0 741 730 0.1 Ring B -50.2 -45.6 135.9 692 681 0.7 Ring B -46.5 -41.9 118.9 648 638 0.8 Ring B -42.6 -38.0 104.7 608 599 2.4 Ring B -38.5 -33.9 82.7 541 533 -0.2 Ring B -34.5 -29.9 65.0 480 473 -2.0 Ring B -6.5 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 3/1/2017 Test File: 2263 Adobe Dr LC Home Multi Point Tectite Comments Connection to: Garage: -45 Pa Mechanicals: -50 Pa