Loading...
HomeMy WebLinkAbout2250 LAGER ST - DISCLOSURES - 3/27/2017Date of Test: 3/27/2017 Customer: Hartford Homes Test Results 1. Airflow at 50 Pascals: (50 Pa= 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level Infiltration Estimates BUILDING LEAKAGE TEST GS Services, LTD 2000 S. College #308 Fort Collins, CO 80525 Test File: Hartford Homes - 2250 Lager St - BD1 Technician: Project Number: Building Address: 2250 Lager St Fort Collins, CO 1002 CFM50 ( +/- 0.8 %) 2.70ACH50 55.1 in2 LBL ELA@ 4 Pa Flow Coefficient (C) = 60.9 ( +/- 6.0 %) Exponent (n) = 0.716 ( +/- 0.017) Correlation Coefficient= 0.99973 Test Standard: RESNET Multi-Point Test Test Mode: Depressurization Standard Level of Accuracy Test 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Matt = Olg:ltally$.. loned Matt Schubert by: Matt emaU Sch u berte,= f< ,m",.ij schubert@2017.C• US 03.O 30 gsservice'S. • 14:GS 15:SeMoes 00- GSSentlces -i.-i:-'·f!- "' BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 3/27/2017 Test File: Hartford Homes - 2250 Lager St - BD1 Building Information Location Climate Information Volume 22256 Ventilation Weather Factor 0.87 Surface Area Energy Climate Factor 17.00 Floor Area 2038 Heating Degree Days 6128 Height Cooling Degree Days 297 # of Bedrooms Design Winter Wind Speed 7.3 mph # of Occupants Design Summer Wind Speed 9.4mph Year of Construction Design Winter Temp Diff 73 deg F Wind Shield M Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 19247 Default Micromanometer Energy Conservatory DG700 19028-7 9/9/2014 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 3/27/2017 Test File: Hartford Homes - 2250 Lager St - BD1 Depressurization Test: Environmental Data Indoor Temperature (A°F) Outdoor Temperature (A°F) Altitude (ft) 68.0 46.0 5000.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -3.2 n/a n/a -62.9 -60.0 39.8 1146 1139 -0.2 Ring A -57.5 -54.6 35.1 1078 1072 0.5 Ring A -51 .2 -48.3 29.4 989 983 0.7 RingA -45.2 -42.3 224.5 887 882 -0.8 Ring B -39.3 -36.4 184.2 804 800 0.1 Ring B -32.8 -29.9 138.2 698 694 -0.0 Ring B -26.9 -24.0 98.3 589 586 -1.1 Ring B -21.1 -18.2 68.7 493 490 0.9 Ring B -2.6 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi-Point Test - Test Parameters None ~es BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 3/27/2017 Test File: Hartford Homes - 2250 Lager St - 801 Comments House WRT Garage= -47.3 Pa