Loading...
HomeMy WebLinkAbout2945 PERCHERON DR - DISCLOSURES - 5/11/2016BUILDING LEAKAGE TEST Date of Test: 05/11/2016 Technician: Jay Bundy Test File: Meritage Blower Door Customer: Meritage Homes 7400 E Orchard Rd Greenwood Village, Colorado 80111 Phone Building Address: 2945 Percheron Drive Fort Collins, Colorado 80525 Test Results 1. Airflow at 50 Pascals: 534 CFM ( +/- 0.4 %) (50 Pa = 0.2 w.c.) 0.81 ACH 0.17 CFM per ft2 floor area 2. Leakage Areas: 18.3 in2 ( +/- 3.7 %) Canadian EqLA @ 10 Pa 5.2 in2 ( +/- 5.6 %) LBL ELA @ 4 Pa 3. Minneapolis Leakage Ratio: 0.08 CFM50 per ft2 surface area 4. Building Leakage Curve: Flow Coefficient (C) = 2.9 ( +/- 8.5 %) Exponent (n) = 1.335 ( +/- 0.021 ) Correlation Coefficient = 0.99963 5. Test Settings: Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 6.6 CFM 0.01 ACH 2. Estimated Design Infiltration Rate: Winter: 6.6 CFM 0.01 ACH Summer: 3.9 CFM 0.01 ACH 3. Recommended Whole Building Mechanical 54.0 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 05/11/2016 Test File: Meritage Blower Door Building Conditions Inside Temperature: 65 deg F Heating Fuel: Gas Outside Temperature: 57 deg F Heating Fuel Cost: # of Stories 1.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 2.0 Volume: 39647 ft3 Ventilation Weather Factor: 0.87 Surface Area: 6815 ft2 Energy Climate Factor: 17.0 Floor Area: 3148 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments BUILDING LEAKAGE TEST Page 3 Date of Test: 05/11/2016 Test File: Meritage Blower Door Data Points: Data Entered Manually Nominal Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow Temperature Adjusted Flow % Error Fan Configuration Baseline Std Dev (Pa) -0.4 n/a +/- 0.00 -65.0 162.1 755 749 -0.3 Ring B -60.0 131.3 680 675 0.0 Ring B -55.0 105.4 610 605 0.9 Ring B -50.0 79.4 530 526 -0.4 Ring B -45.0 59.6 460 456 -0.3 Ring B