Loading...
HomeMy WebLinkAbout2251 CHESAPEAKE DR - DISCLOSURES - 8/23/2016 (4)BUILDING LEAKAGE TEST Date of Test: 8/23/2016 Test File: Multi Point Tectite 2251 Technician: Trevor Donnelly- EnergyLogic Project Number: 42151 Customer: LC Home Building Address: 2251 Chesapeake Dr Ft Collins, CO 80524 Test Results 1. Airflow at 50 Pascals: 1021 CFM50 ( +/- 4.6 %) (50 Pa = 0.2 w.c.) 2.25 ACH50 2. Leakage Area: 56.2 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 15.6 ( +/- 70.0 %) Exponent (n) = 1.069 ( +/- 0.185 ) Correlation Coefficient = 0.98531 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 59.6 CFM 0.13 ACH 11.9 CFM per person 2. Estimated Design Infiltration Rate: Winter: 112.0 CFM 0.25 ACH Summer: 70.3 CFM 0.15 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 65.9 CFM Base Rate: 66.6 CFM Infiltration Credit: <0.7 CFM> You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 8/23/2016 Test File: Multi Point Tectite 2251 Building Information Volume 27265 Surface Area 6329 Floor Area 2908 Height 20 # of Bedrooms 4 # of Occupants 5 Year of Construction 2016 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 7170-5 10/9/2008 You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 8/23/2016 Test File: Multi Point Tectite 2251 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 75.0 85.0 5000.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -2.0 n/a n/a -63.0 -59.3 33.3 1049 1229 0.3 Ring A -57.9 -54.3 25.7 926 1084 -2.7 Ring A -56.7 -53.0 228.0 894 1047 -3.7 Ring B -48.3 -44.7 177.9 790 926 2.3 Ring B -45.7 -42.0 172.0 778 910 7.3 Ring B -41.9 -38.2 132.0 682 799 4.2 Ring B -36.6 -33.0 81.3 536 628 -4.0 Ring B -37.0 -33.4 85.1 549 642 -3.1 Ring B -5.4 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None - * n value outside of normally accepted limits. - * correlation coefficient outside of normally accepted limits. * n value and/or correlation coefficient limits are not officially part of the RESNET Multi-Point Test Standard. You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 8/23/2016 Test File: Multi Point Tectite 2251 Comments Connection to: Garage: -50 Pa Mechanicals: -50 Pa You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com)