HomeMy WebLinkAbout2274 ADOBE DR - DISCLOSURES - 2/8/2017 (4)BUILDING LEAKAGE TEST Date of Test: 2/8/2017 Test File: 2274 Adobe Dr LC Home TECTITE Technician: Zach Kimbrough - EnergyLogic Project Number: 44341 Customer: LC Home Building Address: 2274 Adobe Dr Ft Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 859 CFM50 ( +/- 46.3 %) (50 Pa = 0.2 w.c.) 2.41 ACH50 2. Leakage Area: 47.2 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 8.1 ( +/- 247.3 %) Exponent (n) = 1.192 ( +/- 0.720 ) Correlation Coefficient = 0.85573 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Reduced Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 50.1 CFM 0.14 ACH 12.5 CFM per person 2. Estimated Design Infiltration Rate: Winter: 94.2 CFM 0.26 ACH Summer: 59.1 CFM 0.17 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 2/8/2017 Test File: 2274 Adobe Dr LC Home TECTITE Building Information Volume 21407 Surface Area Floor Area 2357 Height 20 # of Bedrooms 3 # of Occupants 4 Year of Construction 2017 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 36251-7 12/11/2013 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 2/8/2017 Test File: 2274 Adobe Dr LC Home TECTITE Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 68.0 52.0 5000.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -11.4 n/a n/a -69.4 -50.5 175.1 784 829 -4.5 Ring B -64.6 -45.7 146.4 718 758 -1.6 Ring B -60.5 -41.6 121.5 654 691 0.3 Ring B -55.4 -36.4 100.2 595 628 6.7 Ring B -46.2 -27.3 84.2 546 577 38.3 Ring B -43.8 -24.9 48.3 413 437 17.0 Ring B -33.1 -14.2 98.7 226 238 24.3 Ring C -40.2 -21.3 42.1 146 154 -50.6 Ring C -26.4 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None - * n value outside of normally accepted limits. - * correlation coefficient outside of normally accepted limits. * n value and/or correlation coefficient limits are not officially part of the RESNET Multi-Point Test Standard. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 2/8/2017 Test File: 2274 Adobe Dr LC Home TECTITE Comments Garage: -50 PA Mech: -50 PA