Loading...
HomeMy WebLinkAbout2015 KERRY HILL DR - DISCLOSURES - 11/17/2016BUILDING LEAKAGE TEST Date of Test: 11/17/2016 Test File: Mike Campana - 2015 Kerry Hill Dr. - bdma Technician: Project Number: Customer: Mike Campana Building Address: 2015 Kerry Hill Dr. Fort Collins, CO Test Results 1. Airflow at 50 Pascals: 1494 CFM50 ( +/- 4.2 %) (50 Pa = 0.2 w.c.) 2.36 ACH50 2. Leakage Area: 82.1 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 72.4 ( +/- 26.6 %) Exponent (n) = 0.774 ( +/- 0.075 ) Correlation Coefficient = 0.99412 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 11/17/2016 Test File: Mike Campana - 2015 Kerry Hill Dr. - bdma Building Information Volume 37960 Surface Area Floor Area 3884 Height # of Bedrooms # of Occupants Year of Construction Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 11/17/2016 Test File: Mike Campana - 2015 Kerry Hill Dr. - bdma Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 66.0 36.0 5000.0 Data Points - Data Entered Manually Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -4.2 n/a n/a -60.9 -56.4 86.0 1668 1629 -0.7 Ring A -54.8 -50.3 72.9 1539 1503 0.1 Ring A -49.9 -45.4 60.9 1410 1377 -0.8 Ring A -45.3 -40.8 47.9 1254 1225 -4.1 Ring A -39.9 -35.4 42.3 1180 1152 0.7 Ring A -35.4 -30.9 35.9 1089 1063 3.2 Ring A -30.9 -26.4 28.6 976 953 4.4 Ring A -25.1 -20.7 182.2 800 781 3.7 Ring B -20.8 -16.4 104.0 606 592 -5.9 Ring B -4.7 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 11/17/2016 Test File: Mike Campana - 2015 Kerry Hill Dr. - bdma Comments House wrt garage = -45.3 You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com)