Loading...
HomeMy WebLinkAbout2145 SAISON DR - DISCLOSURES - 8/4/2016BUILDING LEAKAGE TEST GS Services Ltd 2000 S. College Ave #308 Fort Collins, CO 80525 Email: BuildingPerformance@GSServices.com Website: GSServices.com Date of Test: 8/4/2016 Test File: Hartford Homes - 2145 Saison Dr - bd1 Technician: Paul higman Project Number: Customer: Hartford Homes Timanth , CO Building Address: 2145 Saison Dr Fort Collins, CO 80524 Test Results 1. Airflow at 50 Pascals: 1236 CFM50 ( +/- 0.8 %) (50 Pa = 0.2 w.c.) 2.81 ACH50 2. Leakage Area: 68.0 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 89.0 ( +/- 6.0 %) Exponent (n) = 0.673 ( +/- 0.017 ) Correlation Coefficient = 0.99970 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 58.5 CFM 0.13 ACH 2. Estimated Design Infiltration Rate: Winter: 82.8 CFM 0.19 ACH Summer: 60.8 CFM 0.14 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 8/4/2016 Test File: Hartford Homes - 2145 Saison Dr - bd1 Building Information Volume 26343 Surface Area Floor Area 2351 Height 10 # of Bedrooms 3 # of Occupants Year of Construction 2016 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 8/4/2016 Test File: Hartford Homes - 2145 Saison Dr - bd1 Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 75.0 71.0 5000.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -0.6 n/a n/a -60.7 -60.1 55.7 1350 1391 -0.5 Ring A -54.5 -53.9 48.5 1261 1300 0.0 Ring A -48.5 -47.9 41.0 1163 1198 -0.3 Ring A -42.5 -41.9 34.3 1065 1097 -0.0 Ring A -36.5 -35.9 28.2 969 998 0.9 Ring A -30.6 -30.0 210.8 860 886 1.2 Ring B -24.6 -24.0 149.9 726 748 -0.9 Ring B -18.4 -17.8 101.4 598 616 -0.3 Ring B -0.6 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 8/4/2016 Test File: Hartford Homes - 2145 Saison Dr - bd1 Comments House WRT Garage = -46.7pa