HomeMy WebLinkAbout4509 KIT DEN DR - DISCLOSURES - 5/20/2020 (4)BUILDING LEAKAGE TEST Date of Test: 5/20/2020 Test File: 4509 Kit Den Dr Technician: Trevor Donnelly (EnergyLogic) Project Number: Customer: LC Home Phone: Fax: Building Address: 4509 Kit Den Dr Ft Collins, CO 80525 Test Results at 50 Pascals: cfm50 Airflow 1103 (+/- 6.1 %) ACH50 1.65 Leakage Areas: 94.7 in² (+/- 17.1 %) Canadian EqLA @ 10 Pa 45.4 in² (+/- 28.3 %) LBL ELA @ 4 Pa Building Leakage Curve: Flow Coefficient (C) = 55.5 (+/- 45.4 %) Exponent (n) = 0.764 (+/- 0.125) Correlation Coefficient = 0.99608 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) 100 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 5/20/2020 Test File: 4509 Kit Den Dr Building Information Volume (ft³) 40135 Surface Area: (ft²) Floor Area: (ft²) Height (ft) 20 Year of Construction 2020 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 5/20/2020 Test File: 4509 Kit Den Dr Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 65.0 75.0 Post-Test 65.0 75.0 Average 65.0 75.0 5000.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration 0.0 n/a n/a -60.0 -60.0 45.6 1224 1308 3.2 Ring A -50.0 -50.0 32.1 1032 1102 -0.1 Ring A -40.0 -40.0 197.2 832 889 -4.4 Ring B -30.0 -30.0 137.2 695 743 -0.5 Ring B -20.0 -20.0 77.3 523 559 2.0 Ring B 0.0 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 5/20/2020 Test File: 4509 Kit Den Dr Comments House to garage: -48 pass