Loading...
HomeMy WebLinkAbout2803 HARVEST VIEW WAY - DISCLOSURES - 8/10/2020BUILDING LEAKAGE TEST Date of Test: 8/10/2020 Test File: 2803 Harvest View Way final tectite Technician: Andrew Hannig- Burgess Construction Consultants Project Number: Customer: Toll Brothers Phone: Fax: Building Address: 2803 Harvest View Way Fort Collins, Colorado 80528 Test Results at 50 Pascals: cfm50 Airflow 2341 (+/- 1.4 %) ACH50 2.15 cfm/ft² (Floor Area) 0.3810 cfm/ft² (Surface Area) 0.1860 Leakage Areas: 399.2 in² (+/- 10.1 %) Canadian EqLA @ 10 Pa or 0.0317 in²/ft² Surface Area 282.9 in² (+/- 16.0 %) LBL ELA @ 4 Pa or 0.0225 in²/ft² Surface Area Building Leakage Curve: Flow Coefficient (C) = 623.8 (+/- 24.9 %) Exponent (n) = 0.338 (+/- 0.064) Correlation Coefficient = 0.98660 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 80 Building Pressure (Pa) 900 1000 2000 3000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 8/10/2020 Test File: 2803 Harvest View Way final tectite Building Information Volume (ft³) 65461 Surface Area: (ft²) 12588 Floor Area: (ft²) 6145 Height (ft) 10.5 Year of Construction 2020 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 8/10/2020 Test File: 2803 Harvest View Way final tectite Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 70.0 70.0 Post-Test 70.0 70.0 Average 70.0 70.0 4726.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -0.9 n/a n/a -65.0 -63.9 222.2 2650 2574 1.2 Ring A -60.0 -58.9 204.5 2545 2472 -0.1 Ring A -55.0 -53.9 190.7 2460 2389 -0.5 Ring A -50.0 -48.9 171.4 2335 2268 -2.4 Ring A -45.0 -43.9 172.2 2340 2273 1.5 Ring A -40.0 -38.9 154.5 2220 2156 0.3 Ring A -35.0 -33.9 139.9 2115 2054 0.1 Ring A -1.4 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - n value (0.338) outside of acceptable limits (0,5 ≤ n ≤ 1). - Correlation coefficient (0.987) outside of acceptable limits. - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 8/10/2020 Test File: 2803 Harvest View Way final tectite Comments Garage with respect to home @ 50Cfm =49.2 Cfm