HomeMy WebLinkAbout2920 RELIANT ST - DISCLOSURES - 9/9/2020 (4)BUILDING LEAKAGE TEST Date of Test: 9/9/2020 Test File: 2920 Reliant St Lennar TECTITE Technician: Adrian Calderon - EnergyLogic Project Number: Customer: Lennar Phone: Fax: Building Address: 2920 Reliant St Ft Collins , CO 80521 Test Results at 50 Pascals: cfm50 Airflow 978 (+/- 5.5 %) ACH50 1.65 cfm/ft² (Floor Area) 0.2606 Leakage Areas: 86.8 in² (+/- 15.9 %) Canadian EqLA @ 10 Pa 42.4 in² (+/- 26.1 %) LBL ELA @ 4 Pa Building Leakage Curve: Flow Coefficient (C) = 53.3 (+/- 41.9 %) Exponent (n) = 0.744 (+/- 0.114) Correlation Coefficient = 0.99651 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 80 Building Pressure (Pa) 100 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 9/9/2020 Test File: 2920 Reliant St Lennar TECTITE Building Information Volume (ft³) 35668.81 Surface Area: (ft²) Floor Area: (ft²) 3754.6 Height (ft) 19 Year of Construction 2020 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 9/9/2020 Test File: 2920 Reliant St Lennar TECTITE Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 58.0 39.0 Post-Test 58.0 39.0 Average 58.0 39.0 4950.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration 0.0 n/a n/a -60.6 -60.6 41.6 1171 1159 2.6 Ring A -52.6 -52.6 29.1 984 973 -4.2 Ring A -39.9 -39.9 202.5 843 834 0.8 Ring B -30.2 -30.2 135.6 691 684 1.7 Ring B -20.5 -20.5 72.0 505 500 -0.9 Ring B 0.0 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - An interval between building pressures exceeds 10 Pa. - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 9/9/2020 Test File: 2920 Reliant St Lennar TECTITE Comments House to Garage Connection Tested at -47.5