Loading...
HomeMy WebLinkAbout2814 HARVEST VIEW WAY - DISCLOSURES - 10/26/2020BUILDING LEAKAGE TEST Date of Test: 10/26/2020 Test File: 2814 Harvest View Way - Tectite Results Technician: Jay - Burgess Construction Consultants Project Number: Customer: Toll Brothers Phone: Fax: Building Address: 2814 Harvest View Way Fort Collins, Colorado 80528 Test Results at 50 Pascals: cfm50 Airflow 1426 (+/- 0.6 %) ACH50 1.53 cfm/ft² (Floor Area) 0.2765 cfm/ft² (Surface Area) 0.1276 Leakage Areas: 93.4 in² (+/- 4.2 %) Canadian EqLA @ 10 Pa or 0.0084 in²/ft² Surface Area 38.4 in² (+/- 6.7 %) LBL ELA @ 4 Pa or 0.0034 in²/ft² Surface Area Building Leakage Curve: Flow Coefficient (C) = 37.1 (+/- 10.3 %) Exponent (n) = 0.933 (+/- 0.027) Correlation Coefficient = 0.99969 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 80 Building Pressure (Pa) 100 200 300 400 500 600 700 800 900 1000 2000 3000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 10/26/2020 Test File: 2814 Harvest View Way - Tectite Results Building Information Volume (ft³) 55876 Surface Area: (ft²) 11176 Floor Area: (ft²) 5156 Height (ft) 10.5 Year of Construction 2020 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 10/26/2020 Test File: 2814 Harvest View Way - Tectite Results Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 64.0 11.0 Post-Test 64.0 11.0 Average 64.0 11.0 4952.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration 0.5 n/a n/a -65.0 -64.4 124.1 1995 1799 -0.4 Ring A -60.0 -59.4 108.1 1865 1682 0.4 Ring A -55.0 -54.4 91.0 1715 1547 0.2 Ring A -50.0 -49.4 74.0 1550 1398 -0.8 Ring A -45.0 -44.4 62.3 1426 1286 0.7 Ring A -40.0 -39.4 48.8 1265 1142 -0.1 Ring A -35.0 -34.4 37.6 1114 1005 -0.1 Ring A -1.6 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 10/26/2020 Test File: 2814 Harvest View Way - Tectite Results Comments Garage with Respect to House @50PA: 45.1