HomeMy WebLinkAbout221 E Oak St - Disclosures/Blower Door Test - 11/05/2020BUILDING LEAKAGE TEST Date of Test: 11/5/2020 Test File: 221 E Oak Unit A Technician: Trevor Donnelly (EnergyLogic) Project Number: Customer: Philgreen Phone: Fax: Building Address: 221 E Oak Unit A Fort Collins, CO 80524 Test Results at 50 Pascals: cfm50 Airflow 1052 (+/- 5.7 %) ACH50 2.42 Leakage Areas: 100.8 in² (+/- 16.2 %) Canadian EqLA @ 10 Pa 51.5 in² (+/- 26.8 %) LBL ELA @ 4 Pa Building Leakage Curve: Flow Coefficient (C) = 69.1 (+/- 43.0 %) Exponent (n) = 0.696 (+/- 0.118) Correlation Coefficient = 0.99576 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) 100 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 11/5/2020 Test File: 221 E Oak Unit A Building Information Volume (ft³) 26026 Surface Area: (ft²) Floor Area: (ft²) Height (ft) 20 Year of Construction 2020 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 11/5/2020 Test File: 221 E Oak Unit A Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 75.0 70.0 Post-Test 75.0 70.0 Average 75.0 70.0 5000.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration 0.0 n/a n/a -60.0 -60.0 43.2 1192 1232 3.2 Ring A -50.0 -50.0 30.9 1013 1046 -0.5 Ring A -40.0 -40.0 198.7 835 863 -4.2 Ring B -30.0 -30.0 144.8 714 738 0.1 Ring B -20.0 -20.0 84.6 547 565 1.6 Ring B 0.0 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 11/5/2020 Test File: 221 E Oak Unit A Comments no garage