HomeMy WebLinkAbout214 LORIEN LN - DISCLOSURES - 10/28/2020 (7)BUILDING LEAKAGE TEST EnergyLogic PO Box N Berthoud , Colorado 80513 Date of Test: 10/28/2020 Test File: 214 Lorien Lane Unit 206 Signature Construction TECTITE Technician: Adrian Calderon Project Number: Customer: Signature Construction Phone: Fax: Building Address: 214 Lorien Lane Unit 206 Fort Collins , CO 80525 Test Results at 50 Pascals: cfm50 Airflow 842 (+/- 1.0 %) ACH50 cfm/ft² (Surface Area) 0.2554 Leakage Areas: 84.7 in² (+/- 2.6 %) Canadian EqLA @ 10 Pa or 0.0257 in²/ft² Surface Area 44.5 in² (+/- 4.3 %) LBL ELA @ 4 Pa or 0.0135 in²/ft² Surface Area Building Leakage Curve: Flow Coefficient (C) = 62.2 (+/- 7.0 %) Exponent (n) = 0.666 (+/- 0.019) Correlation Coefficient = 0.99988 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) 100 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 10/28/2020 Test File: 214 Lorien Lane Unit 206 Signature Construction TECTITE Building Information Volume (ft³) Surface Area: (ft²) 3298.3 Floor Area: (ft²) Height (ft) 18 Year of Construction 2020 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 10/28/2020 Test File: 214 Lorien Lane Unit 206 Signature Construction TECTITE Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 72.0 45.0 Post-Test 72.0 45.0 Average 72.0 45.0 5030.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration 0.0 n/a n/a -57.6 -57.6 249.6 935 921 -0.5 Ring B -49.9 -49.9 207.9 854 841 0.0 Ring B -40.6 -40.6 158.2 746 735 0.2 Ring B -31.3 -31.3 112.5 630 621 0.7 Ring B -18.3 -18.3 53.5 436 429 -0.4 Ring B 0.0 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - An interval between building pressures exceeds 10 Pa. - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 10/28/2020 Test File: 214 Lorien Lane Unit 206 Signature Construction TECTITE Comments None