HomeMy WebLinkAbout209 S Herwood St - Disclosures/Blower Door Test - 09/16/2020BUILDING LEAKAGE TEST L&L Home Performance 401 N Link Ln Fort Collins, CO 80524 Phone: 970.221.3180 Fax: 970.568.0690 Email: llinsulationjh@gmail.com Website: www.ll-insulation.com Date of Test: 9/16/2020 Test File: 209 S Sherwood St Technician: Justin Heldenbrand Project Number: Customer: Stratton Custom Homes Doug Bennett 515 N Whitcomb St Fort Collins, CO 80521 Phone: 970.556.4297 Email: doug@strattonbuild.com Building Address: 209 S Sherwood St Fort Collins, CO 80521 Test Results 1. Airflow at 50 Pascals: 278 CFM50 ( +/- 0.9 %) (50 Pa = 0.2 w.c.) 2.75 ACH50 2. Leakage Area: 15.3 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 17.4 ( +/- 6.4 %) Exponent (n) = 0.708 ( +/- 0.018 ) Correlation Coefficient = 0.99968 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 14.3 CFM 0.14 ACH 7.1 CFM per person 2. Estimated Design Infiltration Rate: Winter: 25.4 CFM 0.25 ACH Summer: 16.8 CFM 0.17 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 9/16/2020 Test File: 209 S Sherwood St Building Information Volume 6072 Surface Area 1783 Floor Area 506 Height 13 # of Bedrooms 1 # of Occupants 2 Year of Construction 2020 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 43466-7-700 - Micromanometer Energy Conservatory DG700 43466 9/15/2016 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 9/16/2020 Test File: 209 S Sherwood St Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 74.0 70.0 5003.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -0.4 n/a n/a -60.6 -59.6 176.9 304 315 0.0 Ring C -54.5 -53.5 152.8 282 293 0.1 Ring C -48.9 -47.9 127.8 257 267 -1.2 Ring C -43.7 -42.7 111.8 240 249 0.1 Ring C -36.4 -35.4 87.0 211 219 0.4 Ring C -30.2 -29.2 67.8 186 193 1.3 Ring C -24.4 -23.5 48.8 157 163 -0.0 Ring C -18.9 -17.9 33.1 129 133 -0.8 Ring C -1.5 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 9/16/2020 Test File: 209 S Sherwood St Comments BPI ID 5060608 Building Analyst & Infiltration and Duct Leakage Certified Connection to Mech:-50pa Connection to Garage:-46.4