HomeMy WebLinkAbout203 LORIEN LN - DISCLOSURES - 10/23/2020 (7)BUILDING LEAKAGE TEST EnergyLogic PO Box N Berthoud , Colorado 80513 Date of Test: 10/23/2020 Test File: 203 Lorien Lane Unit 206 Signature Construction TECTITE Technician: Adrian Calderon Project Number: Customer: Signature Construction Phone: Fax: Building Address: 203 Lorien Lane Unit 106 Fort Collins, CO 80525 Test Results at 50 Pascals: cfm50 Airflow 843 (+/- 3.1 %) ACH50 cfm/ft² (Surface Area) 0.2192 Leakage Areas: 74.1 in² (+/- 10.0 %) Canadian EqLA @ 10 Pa or 0.0193 in²/ft² Surface Area 36.0 in² (+/- 16.4 %) LBL ELA @ 4 Pa or 0.0094 in²/ft² Surface Area Building Leakage Curve: Flow Coefficient (C) = 44.9 (+/- 26.2 %) Exponent (n) = 0.749 (+/- 0.071) Correlation Coefficient = 0.99866 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) 100 200 300 400 500 600 700 800 900 1000 2000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 10/23/2020 Test File: 203 Lorien Lane Unit 206 Signature Construction TECTITE Building Information Volume (ft³) Surface Area: (ft²) 3844.3 Floor Area: (ft²) Height (ft) 19 Year of Construction 2020 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 10/23/2020 Test File: 203 Lorien Lane Unit 206 Signature Construction TECTITE Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 71.0 18.0 Post-Test 71.0 18.0 Average 71.0 18.0 5030.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration 0.0 n/a n/a -60.0 -60.0 31.2 1017 948 -1.9 Ring A -50.8 -50.8 244.2 925 862 1.0 Ring B -42.0 -42.0 181.3 798 743 0.5 Ring B -32.6 -32.6 126.6 668 622 1.7 Ring B -21.5 -21.5 63.4 474 442 -1.4 Ring B 0.0 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - An interval between building pressures exceeds 10 Pa. - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 10/23/2020 Test File: 203 Lorien Lane Unit 206 Signature Construction TECTITE Comments None