HomeMy WebLinkAbout203 Lorien Ln - Disclosures/Blower Door Test - 10/23/2020BUILDING LEAKAGE TEST EnergyLogic PO Box N Berthoud , Colorado 80513 Date of Test: 10/23/2020 Test File: 203 Lorien Lane Unit 105 Signature Construction TECTITE Technician: Adrian Calderon Project Number: Customer: Signature Construction Phone: Fax: Building Address: 203 Lorien Lane Unit 105 Fort Collins, CO 80525 Test Results at 50 Pascals: cfm50 Airflow 726 (+/- 1.4 %) ACH50 cfm/ft² (Surface Area) 0.1954 Leakage Areas: 65.8 in² (+/- 4.1 %) Canadian EqLA @ 10 Pa or 0.0177 in²/ft² Surface Area 32.5 in² (+/- 6.7 %) LBL ELA @ 4 Pa or 0.0088 in²/ft² Surface Area Building Leakage Curve: Flow Coefficient (C) = 41.6 (+/- 10.8 %) Exponent (n) = 0.731 (+/- 0.030) Correlation Coefficient = 0.99976 Test Standard: E779-10 Test Mode: Depressurization 4 5 6 7 8 9 10 20 30 40 50 60 70 Building Pressure (Pa) 100 200 300 400 500 600 700 800 900 1000 Building Leakage (cfm) Depressurize ____ BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 10/23/2020 Test File: 203 Lorien Lane Unit 105 Signature Construction TECTITE Building Information Volume (ft³) Surface Area: (ft²) 3716.9 Floor Area: (ft²) Height (ft) 10.5 Year of Construction 2020 Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 10/23/2020 Test File: 203 Lorien Lane Unit 105 Signature Construction TECTITE Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) Pre-Test 72.0 18.0 Post-Test 72.0 18.0 Average 72.0 18.0 5030.0 Data Points - Data Entered Manually (TTE 5.0.8.4) Nominal Building Pressure (Pa) Baseline adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration 0.0 n/a n/a -58.2 -58.2 213.3 865 806 -0.7 Ring B -51.6 -51.6 180.8 797 743 -0.1 Ring B -39.3 -39.3 123.2 659 614 0.8 Ring B -30.1 -30.1 82.7 541 504 0.6 Ring B -20.2 -20.2 44.8 399 372 -0.7 Ring B 0.0 n/a n/a Deviations from Standard ASTM E779-10 - Test Parameters - An interval between building pressures exceeds 10 Pa. - Pressurization test not included. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 10/23/2020 Test File: 203 Lorien Lane Unit 105 Signature Construction TECTITE Comments None